LEGRAND 675 20 Manuale utente

November 09 PC
SecurityConfig
Software for the Configuration
of the 675 20 Burglar Alarm Unit
User manual


3
SecurityConfig
Contents
1. Hardware and Software requirements.................................................................................................... 4
2. Installation..................................................................................................................................................................... 4
3. Basic concepts............................................................................................................................................................. 5
3.1 Menus and general buttons for selecting functions 6
4. Importing data from an existing project .............................................................................................. 8
4.1 Importing voice messages 8
4.2 Importing configuration data 9
5. Connecting to the Unit...................................................................................................................................... 10
6. Exchanging data with the Unit ................................................................................................................... 12
7. Parameters.................................................................................................................................................................. 13
7.1 Work area 13
7.1.1 Data input procedure 14
7.2 Exchanging configuration parameters with the Unit 16
7.2.1 Receiving configuration parameters 16
7.2.2 Sending configuration parameters 17
7.2.3 Receiving the history of events 19
7.3 Configuration of the Burglar alarm section 21
7.3.1 Zones 22
7.3.2 Automations 26
7.3.3 User Preferences 32
7.3.4 Installer Preferences 33
7.3.5 Key management 34
7.3.6 Scenarios 36
7.4 Configuration of the Dialling device section 37
7.4.1 Telephone number directory 38
7.4.2 Setting up calls 39
7.4.3 Telephone functions 40
7.4.4 Block (Lock) 42
7.4.5 Protocol - ADEMCO 43
7.4.6 Line test 44
7.4.7 Telephone commands 45
8. Messages...................................................................................................................................................................... 46
8.1 Work area 46
8.2 Exchanging voice messages with the Unit 47
8.2.1 Sending voice messages 47
8.2.2 Listening to messages from the Unit loudspeaker 48
8.2.3 Receiving voice messages 48
8.3 Voice message commands 49
8.3.1 Importing an audio file 49
8.3.2 Emitting a voice message 49
8.3.3 Recording a voice message 49
8.3.4 Retrieving voice messages 49
9. Update Firmware ................................................................................................................................................... 50

4
SecurityConfig
Hardware requirements
•Personal Computer with Pentium processor > 400 MHz
•256 MB RAM
•SVGA graphics card with resolution 800 x 600
•CD-ROM unit
•Mouse
Software requirements
•Windows XP or higher - Internet Explorer 6.0 or higher
Space used on hard-disk
•91 Mbyte
1. Hardware
and Software
requirements
Follow this procedure to install the SecurityConfig program:
1. Insert the CD-ROM in the drive.
2. After displaying the main page in the web format, select“Install SecurityConfig”.
3. The installation program will now copy the system files necessary for the execution of the
SecurityConfig program.
2. Installation
Please note:
The SecurityConfig program is the
essential tool for the configuration
of the 675 20 Burglar alarm Unit.
The content of this program is
under the exclusive rights
of Legrand.

5
SecurityConfig
3. Basic concepts
The SecurityConfig software is used for the configuration of the 675 20 Burglar alarm Unit which combine
the burglar alarm and telephone dialling device into one device.
After opening the program, the following screen will appear:
Depending on the technician and user’s needs, it is possible to begin with a new configuration or
change an existing configuration.
In this manual the various screens will refer to the second mode.
Creating a new configuration
•Start SecurityConfig
• Execute and save the configuration
• Send data to the Unit
Modifying an existing configuration
•Execute the system auto-learning function from the Unit
• Receive data from the Unit with SecurityConfig
• Edit, if required
• Send data to the Unit
In order to perform a proper configuration, it is necessary to execute the system auto-learning function
before connecting the Unit to the PC.
Using the Firmware Update function, with the SecurityConfig it is also possible to update the permanent
Control Unit Software, using new issues published by Legrand.
Please note:
For proper functioning of the
software, the 675 20 Burglar
Alarm Unit must be installed
according to the indications
specified in the installation
manual supplied
with the device.

6
SecurityConfig
3.1 Menus and general buttons for selecting functions
The main functions that can be executed with SecurityConfig can be selected by using the icons in the
toolbar or by opening drop-down menus, thus selecting the various options.
Quick keys can also be used for some functions, like: to create a new project, it is possible to select New
from the File drop-down menu, from the toolbar and from the keyboard by using the keys Ctrl + N.
The followings functions are included in the toolbar:
Create a new
project
Save the current
project
Opens the
Parameters section
Executes connection
to the Unit
Opens an existing
project
Opens the Voice
message section
Selects the serial port
of the PC to which the
Unit is connected
Executes connection
to the Legrand website
Select the interface
language
The followings functions are included in the drop-down menus:
“File” menu
•New Creates a new project
•Open Opens an existing project
•Save Saves the current project
•Save as (with name) Saves the project after requesting a file name
•Export configuration Exports the project thus creating a file with
extension .csv which can be imported into
Microsoft Excel®
•Exit Exits the program
“Edit” menu
•Import messages from project Imports all voice messages from an existing
project
•
Import configuration data from project
Imports all configuration data from an existing
project
•Load pre-defined audio messages Retrieves voice messages set up for the Unit
•Select all messages Selects all messages of the project
•Select all fixed messages Selects all fixed messages of the project

7
SecurityConfig
“?” menu
•About… Displays information on the SecurityConfig program
•Supported versions Displays information on SecurityConfig, hardware and
software versions of the Unit
The status bar shows the following information:
Current data
Current time
Loaded project file
“Language” menu
•
Select the SecurityConfig interface language
Type of Unit
“Tools” menu
•Parameters Opens the Parameters section
•Messages Opens the Messages section
•Receive configuration Receives the configuration from the Unit, it is active only
when connecting to the Unit
•Send configuration Sends the configuration to the Unit, it is active only when
connecting to the Unit
•Update Firmware Starts the Unit firmware update procedure
•Connection to Unit Enables connection between the PC and the Unit

8
SecurityConfig
>Select Import messages from project from the Edit menu
>Select the project file (. jai) from where you want to import the messages
>Click the Open button
When the procedure has been completed, the imported messages will appear:
4.1 Importing voice messages
To import voice messages from a project file:
The following screen will appear:
4. Importing data from
an existing project
It is possible to import data (configuration parameters and voice messages) from a previously saved
project file.
Please note:
It is recommend to save the
current configuration file of before
starting the procedure.

9
SecurityConfig
>Select Import configuration data from project from the Edit menu
>Select the project file (. jai) from where you want to import the configuration
>Click the Open button
When the procedure has been completed, the new configuration will appear:
4.2 Importing configuration data
To import a previously saved configuration:
The following screen will appear:
Please note:
It is recommend to save the
current configuration file of before
starting the procedure.

10
SecurityConfig
b
a
b
T1T1
OFF
ON
b
a
b
T1T1
OFF
ON
>Select Connection to Unit from the Tools menu
The following message will appear:
5. Connecting
to the Unit
To access some functions (e.g. Receive configuration, Send messages, etc.) there must be a connection
between the PC where SecurityConfig is installed and the Unit, following the operation described
below.
>From the Port menu, select the serial port address of the PC you want to connect the Unit to (COM1,
COM2, etc.)
> Execute the required operations and then click OK
Select the maintenance menu
of the Unit and start
the auto-learning function
Slide switch
0492 34
Flip the slide switch to off
Click the OK button
Connect the programming cable
to a USB port of the PC and to
the 6-way connector of the Unit
Language
Key program
System test
Learning
Altri manuali per 675 20
1
Indice
Manuali Software popolari di altre marche

PS Audio
PS Audio PowerPlay Manuale del proprietario

Brady
Brady LOCKOUT PRO 3.0 Manuale di servizio

Avaya
Avaya Interaction Center Manuale utente

Texas Instruments
Texas Instruments TI-83 Plus Silver Edition Manuale

Novell
Novell GROUPWISE 8 - INTERNET AGENT Manuale utente

Oracle
Oracle Application 9i Manuale utente

Acer
Acer RDM Manuale utente

Canon
Canon Vixia HF21 Manuale utente

Canon
Canon ZR950 Manuale utente

Samsung
Samsung Auto Backup Manuale utente

Polycom
Polycom Vortex EF2201 Istruzioni per l'installazione e il funzionamento

Brocade Communications Systems
Brocade Communications Systems Brocade 8/12c Manuale utente