LEYBOLD PS 113 A Manuale utente

P
S
Lo
w
Operat
Part Num
230 011
S
1
1
w
-Pre
s
ing Man
ber
1
3
A
s
sure
ual GA
0
A
Safe
t
0
9616_0
0
t
y S
w
0
2_C0
w
itch

General Information
2GA09616_002_C0 – (2016-10) – Leybold
Product Identification
In all communications with Leybold, please specify the information on the product
nameplate.
Validity
This document applies to products with part number:
230 011
The part number (No:) can be found on the product nameplate.
We reserve the right to make technical changes without prior notice.
All dimensions are indicated in mm.
The references to diagrams, e.g. (4/5), consist of the fig. no. and the item no. in
that order.
Description
The low-pressure safety switch PS 113 A is used as a pressure safety switch in
vacuum systems.
Intended Use
The low-pressure safety switch PS 113 A is used as a pressure safety switch in
vacuum systems. It is used e.g. to automatically interrupt the gas supply when
venting vacuum systems with a purge gas at a pressure of 3 mbar below atmos-
pheric pressure.
Unpacking and Checking
Unpack the low-pressure safety switch PS 113 A immediately after delivery, even if
it is to be put into operation at a later date.
Before doing so, examine the shipping container for any external damage. Then
completely remove the packaging materials.
The shipping container and packaging materials must be kept in the event of com-
plaints about damage.
In order to ensure that no damages have been caused during transport carefully
examine low-pressure safety switch PS 113 A visually.
If any damage is discovered, report it immediately to the forwarding agent and
insurer. If the damaged part has to be replaced, please get in touch with the orders
department.

General Information
GA09616_002_C0 – (2016-10) – Leybold 3
Design and Function
At a differential pressure of 6 mbar when pumping down or 3 mbar when venting
below atmospheric pressure, an elastic diaphragm actuates a changeover contact
which in turn may be used to directly switch any ancillary equipment. The electrical
connections are placed under a plastic cover.
Scope of Delivery
Low-pressure safety switch PS 113 A complete with cable, 3 m
Operating Manual German
Operating Manual English

Contents
4GA09616_002_C0 – (2016-10) – Leybold
Contents
Product Identification 2
Validity 2
Description 2
Intended Use 2
Unpacking and Checking 2
Design and Function 3
Scope of Delivery 3
1Safety 5
1.1 Symbols Used 5
1.2 Personnel Qualifications 5
1.3 General Safety Instructions 5
1.4 Liability and Warranty 6
2Technical Data 6
3Installation 7
3.1 Vacuum Connection 7
3.2 Electrical Connection 7
3.3 Start up 7
4Maintenance 8
5Returning the Product 8
6Disposal 9
Declaration of Contamination 10
EU Declaration of Conformity 11
Für Seitenverweise im Text wird das Symbol (→XY) verwendet, für Verweise
auf andere Dokumente das Symbol (→[Z]).

Safety
GA09616_002_C0 – (2016-10) – Leybold 5
1 Safety
1.1 Symbols Used
Symbols for residual risks
DANGER
Information on preventing any kind of physical injury.
WARNING
Information on preventing extensive equipment and environmental damage.
Caution
Information on correct handling or use. Disregard can lead to malfunctions or
minor equipment damage.
Notice
1.2 Personnel Qualifications
Skilled personnel
All work described in this document may only be carried out by persons who
have suitable technical training and the necessary experience or who have been
instructed by the end-user of the product.
1.3 General Safety Instructions
•Adhere to the applicable regulations and take the necessary precautions for the
process media used.
Consider possible reactions between the materials (→6) and the process
media.
•Adhere to the applicable regulations and take the necessary precautions for all
work you are going to do and consider the safety instructions in this document.
•Before beginning to work, find out whether any vacuum components are con-
taminated. Adhere to the relevant regulations and take the necessary pre-
cautions when handling contaminated parts.
Communicate the safety instructions to other users.

Safety, Technical Data
6GA09616_002_C0 – (2016-10) – Leybold
1.4 Liability and Warranty
Leybold assumes no liability and the warranty becomes null and void if the end-
user or third parties
•disregard the information in this document
•use the product in a non-conforming manner
•make any kind of changes (modifications, alterations etc.) to the product
•use the product with accessories not listed in the corresponding product
documentation.
2 Technical Data
Switching pressure 6 mbar
(
below atmospheric pressure)
Return switching pressure 3 mbar
(
below atmospheric pressure)
Switching inaccuracy ±2 mbar
Max. operating pressure (abs.) 2000 mbar
Operating temperature 0 to 85 °C
Helium permeation <1·10-6 mbar·l·s-1
Switching contact changeover contact
Switching capacity 100 mA / 24 VAC
30 mA / 24 VDC
Electrical connection standard cable 3 m
Vacuum connection DN 16 KF
Protection type IP 44
Materials in contact with the medium stainless steel 1.4305, 1.4310
stainless steel 1.4300 PTFE coated
EPDM
Internal volume 2
cm
3
Weight
315 g
Dimensions [mm]
Fig. 1 Dimensional diagram
PS 113 A

Installation
GA09616_002_C0 – (2016-10) – Leybold 7
3 Installation
3.1 Vacuum Connection
The PS 113 A is connected to the vacuum system via a DN 16 KF small flange.
The PS 113 A should preferably be mounted standing on its flange. Inclined
mounting is also permissible, including the horizontal position. Downward installa-
tion is not permissible because in such a case condensate may collect in the pres-
sure switch. This affects the measurements and may damage the pressure switch.
3.2 Electrical Connection
Fig. 2 Contact assignment of microswitch
The contact assignment is given in Fig. 2.
The PS 113 A is supplied with a connected 3 m long standard cable. The length of
this cable may be changed.
The electrical connection terminals and the strain relief are accessible after un-
screwing the cross head screws and folding out the cap.
The contacts at the PS 113 A are marked 1, 2 and 3 (see contact assignment
Fig. 2).
The supply line has to be fuse-protected with max. 100 mA by the end-user.
Adhere to the applicable regulations and take the necessary precautions for all
work you are going to do.
3.3 Start up
When leak detecting with a helium leak detector, spraying the pressure switch with
helium may result in a helium proof. This is in general not due to a leak of the
PS 113 A, but is permeation of helium through the EPDM diaphragm.

Maintenance, Returning the Product
8GA09616_002_C0 – (2016-10) – Leybold
4 Maintenance
The PS 113 A requires no maintenance
5 Returning the Product
WARNING
WARNING: forwarding contaminated products
Products returned to Leybold for service or repair should preferably be
free of harmful substances (e.g. radioactive, toxic, caustic or
microbiological).
Adhere to the forwarding regulations of all involved countries and
forwarding companies and enclose a completed declaration of con-
tamination (Form under www.leybold.com).
Products that are not clearly declared as "free of harmful substances" are de-
contaminated at the expense of the customer.
When returning a product to Leybold, put it in a tight and impact resistant package.

Disposal
GA09616_002_C0 – (2016-10) – Leybold 9
6 Disposal
DANGER
DANGER: contaminated parts
Contaminated parts can be detrimental to health.
Before beginning to work, find out whether any parts are contami-
nated. Adhere to the relevant regulations and take the necessary
precautions when handling contaminated parts.
WARNING
WARNING: substances detrimental to the environment
Electronic components must be disposed of in accordance with special
regulations.
Dispose of such products in accordance with the relevant local regu-
lations.
Separating the components
After disassembling the product, separate its components according to the follow-
ing criteria:
Contaminated components
Contaminated components (radioactive, toxic, caustic, or biological hazard etc.)
must be decontaminated in accordance with the relevant national regulations,
separated according to their materials, and recycled.
Other components
Such components must be separated according to their materials and recycled.

Declaration of Contamination
10 GA09616_002_C0 – (2016-10) – Leybold
Declaration of Contamination
Altri manuali per PS 113 A
1
Questo manuale è adatto per i seguenti modelli
1
Altri manuali LEYBOLD Interruttore