LinkAYL LK-CP63 Series Manuale utente


www.linkayl.com Copyright © Linkayl Technology Limited
LK-CP63X Control Panel
¢Terminal
03 04
¢Key & LED
LED/KEY
Color
Status
Funcon
L1 / K1
Blue
On/Off
AC power, Reset
L2 / K2
Green
On/Off/Flash
Open
L3 / K3
Red
On/Off
Stop
L4 / K4
Yellow
On/Off
Close
L5 / K5
Blue
On/Off
Channel 1
L6 / K6
Blue
On/Off
Channel 2
L7 / K7
Blue
On/Off
Channel 3
L8 / K8
Blue
On/Off
Channel 4
L9 / K9
Blue
On/Off
Channel 5
Symbol
Descripon
Symbol
Descripon
L
AC live wire
FSO
Fire signal output
N
AC null wire
FOO
Fire output NO
E
AC earth wire
FOC
Fire output NC
24V+
24VDC input posive
24V
24VDC+ output
24V-
24VDC input negave
FSI
Fire signal input
M+
24VDC motor posive
COM
Sensor COM
M -
24VDC motor negave
S+
Slave control up
MU
Manual switch up
S-
Slave control down
MS
Manual switch stop
12V
DC12V+ output
MD
Manual switch down
WRD
Rain sensor down
MG
Manual switch GND
T/H
T/H signal
FSO
FOO
FOC
24V
FSI
COM
MU
MS
MD
MG
S+
S-
12V
WRD
T/H
ON
OPTION
N
Y
Drive Board
Control Board
Power Supply
AC INPUT M1 M2 M3 M4 M5
L N E M+ M- M+ M- M+ M- M+ M- M+ M-
24V+
L
24V-
N
E
Unit: mm

www.linkayl.com Copyright © Linkayl Technology Limited
LK-CP63X Control Panel
¢Manual control
05 06
¢Control mode
—Aer power on all the LEDs light for 1 second and turn off, the power indicator LED
normally on
—Press reset buon, all the LEDs light for 1 second and turn off, reset successfully
—L2 will be explosion-flashing aer controller receives fire signal
—External manual switch is equivalent to controller panel switch
—The maximum running me of the motor is 5 minutes
.
.
£Group control
—Controller has inching mode and connued-run mode which is default
—In the connued-run mode, press UP or DOWN buon less than 1.5 seconds, the motor
will run connuously, press UP or DOWN buon more than 1.5 seconds, the motor will
stop aer running a very short moment
—In the inching mode, press UP or DOWN buon less than 1.5 seconds, the motor will stop
aer running a very short moment, press UP or DOWN buon more than 1.5 seconds,
the motor will run connuously
—Only the manual buons on the panel, manual switch, remote control and cascade signal
have inching mode
—Keep pressing both of UP and STOP buon on the controller for 5 seconds, LEDs flash 3
mes and turn off it's inching mode for the controller, repeat the operaon the controller
turns to connued-run mode
—By default, L1 is normally on, the rest LEDs are off as group control status
—Press UP buon, the windows open, LED turns on, turns off aer 5 seconds
—Press DOWN buon, the windows close, LED turns on, turns off aer 5 seconds
—Press STOP buon, ,the motors stop, LED turns on, LED turns off aer 1 second
£Channel control
—Press channel selecon keys the corresponding LED lights, channel selected
—Press the channel selecon buon again or no operaon on controller thin 10 seconds,
LED turns off, channel unselected
—In the process of opening/closing the current window, you can select another channel(s)
to drive the window
.
¢Remote control
—The controller encodes by 433MHz learning code, can store 10 sets of transmission codes
—The controller defaults to mulple channel, single channel controler has the same way as
mulple channel one
.
£Matching code
—Power the controller on, choose the channel(s) you want to set, can be set to any
combinaon of channel 1-4
—Pressing STOP buon on controller for 5 seconds
—LED flashes 3 mes and turns off
—Choose the channel you want to set on the remote
—Press UP within 15 seconds
—LED flashes 3 mes and turns off
—Code matched successfully
.
£Clearing single code
—Power the controller on
—Keep pressing STOP key on the controller for 5S
—LED flashes 3 mes and turns off
—Press DOWN buon on the remote within 15 seconds
—LED flashes 3 mes and turns off
—Code cleared successfully
.
£Clearing all codes
—Power controller on
—Pressing STOP /DOWN buon on the controller for 5 seconds
—LEDs flash 3 mes and turn off
—All the codes will be deleted aer this operaon


www.linkayl.com Copyright © Linkayl Technology Limited
LK-CP63X Control Panel
¢Troubleshoong
09 10
—Please read the following instrucons carefully before installing this product
—Installing this product must comply with the effecve local electricity specificaons
—The control system must be installed by the professional
—The main power must be cut off before wiring to ensure safe operaon
—Addive maximum output power of each single channel of double channel controller
MUST NOT exceed the total rated power of the controller
—Addive maximum output power of each single channel of 5 channel controller MUST
NOT exceed the total rated power of the controller, and the maximum output current of
each channel MUST NOT exceed 10A
—Do not use metal objects to touch or cover the controller, otherwise it will affect the
remote control signal recepon
—The maximum transmission distance of the wireless signal can reach 50 meters or more
in the open condion
—The distance between the controller and ground should be more than 1.5 meters
—The distance between the controller and ceiling should be more than 0.3 meters
—The distance between the controller and motor should be more than 1.5 meters
—Avoid stac interference and prevent stac damage to electronic components
—Please use the so wire and cable, aer installaon ensure that the cable carrier is not
affected by the longitudinal tension
—An external sensor must use a product that is compable with this controller
—Non-professionals is not allowed to disassemble the controller. If any funcon is
abnormal, please contact your local dealer
.
¢Installaon instrucon
No.
Symptom
Soluon
1
LED flashes, receiver shut down
1. Check the connecon of wires
2. Check the receiver seng
2
LED on the transmier is off or weak
1. Make sure the right installaon of the baery
2. Change the baery
3
The transmier and the receiver work well,
the motor does not work
1. Check the wiring of motor
2. Make sure the motor no failure
¢Stroke memory
—The controller can set and memorize the opening stroke. Upon the stroke set, the
window opening signal is triggered once, the motor will run the memorized stroke one
me
—The default memorized stroke runs for 5 minutes
—Press both of UP /DOWN buons on the controller for 3 seconds, LEDs flash 3 mes and
off, successfully entered the stroke memory seng state
—In the stroke memory seng state, the manual keys are forced to the connued-run
mode, the remote control keys are forced to the inching mode
—Select the channel(S) to be set, the default is all selected, all the channel indicators light.
Press the channel selecon key(s), the indicators light, press the channel selecon key(s)
again the indicator is off, it is deselected. The seng is invalid without operaon in 15
seconds
—Aer the channel selected, determine the stroke that needs to be memorized by pressing
the manual key or the remote control key by moving or jogging
—The memorized stroke can be set to one channel or any combinaon of channel
—Aer the memorized strokes determined, turn on all the channel indicators for seng the
memorized stroke. Press both of UP /DOWN buons on the controller for 3 seconds, LEDs
flash 5 mes and off, the memorized strokes of all channels set successfully and exit the
stroke memory seng state, manual buons and remote control buons restored to the
original mode
—In stroke memory seng state, no operaon is performed within 15 seconds, LEDs flash 3
mes slowly and off, the stroke memory seng state is automacally exited, and the last
memorized stroke is retained
—Stroke memory can be set repeatedly. The controller only retains the last successful
stroke value and automacally clears the previous one
—In stroke memory seng state, press both of STOP /DOWN buons on the controller for
3 seconds LEDs flash 3 mes the memorized stroke is deleted and restored to the default
output for 5 minutes
—When the memorized strokes of master controller and slave controller are not the same,
the master controller will run its own memorized stroke. The slave controller will run the
shorter stroke when it receives the cascade signal from the master controller
—The memorized stroke set for each channel is retained in case the controller is powered
down or reset
—When closing the window, the output me is 5 minutes
Questo manuale è adatto per i seguenti modelli
11
Altri manuali LinkAYL Pannello di controllo

LinkAYL
LinkAYL LK-FP3 Manuale utente

LinkAYL
LinkAYL LK-CP63X Series Manuale utente

LinkAYL
LinkAYL LK-CP611 Manuale utente

LinkAYL
LinkAYL LK-UP24 Series Manuale utente

LinkAYL
LinkAYL LK-UP211 Manuale utente

LinkAYL
LinkAYL LK-UP22 Series Manuale utente

LinkAYL
LinkAYL LK-CP64 Series Manuale utente

LinkAYL
LinkAYL LK-CP62 Series Manuale utente

LinkAYL
LinkAYL LK-CP711-30A Manuale utente