MasterCraft 052-0055-6 Manuale utente

MANUAL
DIGITAL MULTIMETER
INSTRUCTION
MANUAL
model no. 052-0055-6
Read and understand this instruction manual thoroughly
before using the product. It contains important
information for your safety as well as operating and
maintenance advice.
Keep this instruction manual for future use. Should this
product be passed on to a third party, then this
instruction manual must be included.


SAFETY INFORMATION
This meter has been designed according to IEC 61010 concerning
electronic measuring instruments with a measurement category
(CAT III 300V) and pollution degree 2.
2
WARNING
WARNING
To avoid possible electric shock or personal injury, follow these
guidelines:
●
●
●
●
●
●
●
●
Do not use the meter if it is damaged. Before you use the meter,
inspect the case. Pay particular attention to the insulation
surrounding the connectors.
Inspect the test leads for damaged insulation or exposed metal.
Check the test leads for continuity. Replace damaged test leads
before you use the meter.
Do not use the meter if it operates abnormally. Protection may
be impaired. When in doubt, have the meter serviced.
Do not operate the meter where explosive gas, vapour, or dust
is present.
Do not apply more than the rated voltage, as marked on the
meter, between terminals or between any terminal and earth
ground.
Before use, verify the meter's operation by measuring a
known voltage.
When measuring current, turn off circuit power before connect-
ing the meter in the circuit. Remember to place the meter in
series with the circuit.
When servicing the meter, use only specified replacement parts.

●
●
●
●
●
●
●
●
●
●
●
Use caution when working with voltage above 30 V AC RMS,
42 V peak, or 60 V DC. Such voltages pose a shock hazard.
When using the probes, keep your fingers behind the finger
guards on the probes.
Connect the common test lead before you connect the live test
lead. When you disconnect test leads, disconnect the live test
lead first.
Remove the test leads from the meter before you open the
battery cover or the case.
Do not operate the meter with the battery cover or portions of
the case removed or loosened.
To avoid false readings, which could lead to possible electric
shock or personal injury, replace the battery as soon as the low
battery indicator ( ) appears.
Do not use the meter in a manner not specified by this manual
or the safety features provided by the meter may be impaired.
Adhere to local and national safety codes. Individual protective
equipment must be used to prevent shock and arc blast injury
where hazardous live conductors are exposed.
To avoid electric shock and personal injury, do not touch any
naked conductor with hand or skin; and do not ground yourself
while using this meter.
Do not use the meter if the meter, a test lead or your hand is wet.
Remaining endangerment:
When an input terminal is connected to dangerous live potential,
it is to be noted that this potential can occur at all other terminals!
model no. 052-0055-6 | contact us 1-800-689-9928
3
WARNING

●
CAT III - Measurement Category III is for measurements performed
in building installation. Examples are measurements on
distribution boards, circuit breakers, wiring, including cables,
bus-bars, junction boxes, switches, socket-outlets in the fixed
installation, and equipment for industrial use and some other
equipment, for example, stationary motors with permanent
connection to the fixed installation. Do not use the meter for
measurements within Measurement Categories IV.
4
WARNING

To avoid possible damage to the meter or to the equipment under
test, follow these guidelines:
●
●
●
●
Disconnect circuit power and discharge all capacitors thorough-
ly before testing resistance, diode, continuity or temperature.
Use the proper terminals, function and range for your measurements.
Before measuring current, check the meter's fuses and turn off
power to the circuit before connecting the meter to the circuit.
Before turning the rotary switch to change functions, disconnect
the test leads from the circuit under test.
Alternating current
Direct current
Both direct and alternating current
Caution, risk of danger. Refer to the operating manual before
use.
Caution, risk of electric shock.
Earth (ground) terminal
Fuse
Conforms to European Union directives
The equipment is protected throughout by double insulation or
reinforced insulation.
CAUTION
ELECTRICAL SYMBOLS
model no. 052-0055-6 | contact us 1-800-689-9928
5
CAUTION

This meter is a compact 3 1/2-digit digital multimeter designed to
measure DC and AC voltage, DC and AC current, resistance, continuity,
diode, battery and temperature. In addition, non-contact AC voltage
detection, live AC wire detection and illumination functions are also
provided. It features polarity indication, data hold, full-range overload
protection, and more. It is easy to operate and is a very useful test
tool.
FRONT PANEL
INTRODUCTION
2
3
4
5
678
9
10
11
12
13
1
6
INTRODUCTION

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Display
3 1/2-digit LCD, with a max. reading of 1999.
"AC/DC" Button
Used to switch between DC and AC functions.
AC Voltage Detection Button
Backlight Button
Press this button to turn on or off the backlight. The backlight
will turn off automatically about 30 secs after it is turned on.
Function/Range Switch
Used to select desired function or range as well as to turn on or
off the meter. To preserve battery life, set the function/range
switch in the "OFF" position when the meter is not in use.
"10A" Terminal
Plug-in connector for the red test lead for current (200 mA
–
10 A)
measurements.
"COM" Terminal
This terminal is a plug-in connector for the black test lead. It is
also a plug-in connector for the negative (-) plug of a K type
thermocouple for temperature measurements.
"VmAºF" Terminal
This terminal is a plug-in connector for the red test lead for all
measurements except temperature measurements and the
current measurements ≥ 200 mA.
It is also a plug-in connector for the positive (+) plug of a K type
thermocouple for temperature measurements.
Illumination Button
Press and hold down this button to turn on the illumination
lamp. To turn off the illumination lamp, just release this button.
AC Voltage Detection Indicator
model no. 052-0055-6 | contact us 1-800-689-9928
7
INTRODUCTION

GENERAL SPECIFICATIONS
SPECIFICATIONS
11.
12.
13.
"H" Button
Used to enter/exit Data Hold mode.
Holster
Illumination Lamp
Display: 3 1/2-digit LCD, with a max. reading of 1999
Negative Polarity Indication:
Negative sign " - " shown on the display automatically
Sampling Rate: About 2
–
3 times/sec
IP Degree: IP20
Battery: 9 V battery, 6F22 or equivalent, 1 pieces
Low Battery Indication: " " shown on the display
Operating Environment: Temperature: 32 to 104ºF (0 to 40°C)
Relative Humidity: < 75%
Storage Environment: Temperature: 14 to 122ºF (-10 to 50ºC)
Relative Humidity: < 85%
Size: 6 11/16 x 3 3/8 x 1 9/16" (170 x 86 x 40 mm)
Weight: About 10 1/4 oz (291 g) (including battery)
Readings are accurate for a period of one year after calibration at 64
to 82ºF (18 to 28ºC), with relative humidity < 75%.
Accuracy specifications take the form of:
±([% of Reading] + [number of Least Significant Digits])
8
TECHNICAL SPECIFICATIONS

DC VOLTAGE
Input Impedance: 10 MΩ
Max. Allowable Input Voltage: 300 V DC
RANGE
200 mV 100 V ±(0.5% + 5)
±(1.0% + 5)
±(0.8% + 5) "OL" shown
on the display
1 mV
10 mV
100 mV
1 V
2 V
20 V
200 V
300 V
RESOLUTION ACCURACY OVERRANGE
INDICATION
AC VOLTAGE
Frequency Range: 40 – 400 Hz
Response: Average, calibrated in RMS of sine wave
Max. Allowable Input voltage: 300 V AC RMS
RANGE
200 mV 100 V ±(1.0% + 5)
±(1.2% + 5)
"OL" shown
on the display
1 mV
10 mV
100 mV
1 V
2 V
20 V
200 V
300 V
RESOLUTION ACCURACY OVERRANGE
INDICATION
model no. 052-0055-6 | contact us 1-800-689-9928
9
TECHNICAL SPECIFICATIONS
Indice
Altri manuali MasterCraft Multimetro
Manuali Multimetro popolari di altre marche

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuale utente

PeakTech
PeakTech 4000 Manuale per l'uso e la cura

YOKOGAWA
YOKOGAWA 90050B Manuale utente

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuale utente

Fluke
Fluke 8846A Manuale operativo e di manutenzione

Tempo Communications
Tempo Communications MM200 Manuale utente