Matrix DPS Series Manuale utente

1
INTRODUCTION
DPS series programmable power supply provides continuous adjustable output voltage and current as well as
automatic shift between constant voltage and current. It features with high stability & reliability, high accuracy, 4
groups memories by using digital technology, panel lock, output ON/OFF function, voltage & current limit setting
with password, and intelligent temperature control and alert function.
DPS series power supply has three outputs: two with adjustable output voltage and one fixed output voltage
(2.5V, 3.3V, 5V selectable, for DPS-3033GL-3 only).The two adjustable outputs provide both manual and
programmable control modes. When it is turned on, the unit is default) and in manual model. Pressing TIMER
button to set parameters. Pressing RUN or STOP button to turn on or off programmable control output.
As a constant voltage (CV) and constant current (CC) source, DPS series is able to, even at the maximum
output current, provides a fully rated and continuously adjustable output voltage. For a big load, DPS series can be
used as a CV source, the output current can be adjusted via a current regulator on the front panel; when used as a
CV source, the maximum output voltage can be controlled via voltage regulator on the front panel. That is to say,
the power supply will automatically shift from CV source to CC source when the output current reaches the target
value.
CAUTION:
1. The power supply must be operated under the rated line voltage. If the power supply is meant
to work for a long time, it is suggested to use 60%~70% load to as to avoid rapid aging.
2. Avoid frequent short-circuit operations.
3. Do not turn on the power supply when the output terminal is with heavy load. Turn the output
voltage adjustment knob to the lowest value, next connect the load, and then turn on the power
supply. Adjust the voltage/current adjustment knob to set the wanted values.
!

2
2. GENERAL AND PRODUT MODELS
2.1 General
Power source: 110V/220V±10%, 50/60Hz
Operation environment: Indoor use Altitude: <2000m
Relative humidity: <80% Temperature: 1 ℃~40℃
Category: II Pollution degree: II
Storage temperature: -10℃~70℃
Weight: 7.0kgs DPS-3033GL-3, 8.0kgs for DPS-3055GL-3&DPS-6022GL-3
Dimension: 300L*220W*148H (mm)
2.2 Accessories
Power cord: 1pcs
Users manual: 1 pcs
2.3 Product Models
Model Max.Output Voltage/Current Fixed Output Fuse
Voltage Current Input Voltage
110VAC 220VAC
DPS-3033GL-3 30VX2 3AX2 2.5V, 3.3V,5V T6.3A
250V T4A
250V
DPS-3055GL-3 30Vx2 5AX2 NO T6.3A
250V T6.3A
250V
DPS-6022GL-3 60Vx2 2AX2 NO T6.3A
250V T4A
250V

3
DPS-3055GL-3 & DPS-6022GL-3: CH1&CH2 output power limit within 100W.
3. SPECIFICATION
Technical specifications of DPS series should be tested in 30 minutes after unit warm up.
Testing environment: +20 ℃~+30℃
Specifications are subject to changes without notice.

4
Model DPS-3033GL-3 DPS-3055GL-3 DPS-6022GL-3
Output 0~30V/3Ax2 0~30V/5Ax2 0~60V/2Ax2
Constant Voltage Operation
Line regulation CV≤0.01%+3mV CV≤0.02%+3mV CV≤0.02+5mV
Load regulation CV≤0.01%+3mV CV≤0.02+5mV CV≤0.02+5mV
Recovery time ≤100µS (50% load change, minimum load 0.5A)
Ripple&Noise ≤2mV rms (5Hz~1MHz) ≤3mV (5Hz~1MHz)
Temperature ≤300ppm/℃
Programmable Control Features
Programmable point 4 4 4
Programmable time 1 sec.~60min.60sec. 1 sec.~60min.60sec. 1 sec.~60min.60sec.
Time accuracy ±1 sec. ±1 sec. ±1 sec.
Cycling Cyclable Cyclable Cyclable
Model DPS-3033GL-3 DPS-3055GL-3 DPS-6022GL-3
Output 0~30V/3Ax2 0~30V/5Ax2 0~60V/2Ax2
Rising time Empty load 10mS~250mS 10mS~250mS 10mS~250mS
0.5A load 10mS~250mS 10mS~250mS 10mS~250mS
Falling time Empty load 1.0S 1.0S 1.0S
0.5A load 10mS~250mS 10mS~250mS 10mS~250mS
CH3 Output (DPS-3033GL-3 only)
Regulation Line regulation≤5mV, load regulation≤15mV
Ripple&Noise ≤2mV rms

5
4. SAFETY INSTRUCTION
Voltage range 2.5V, 3.3V, 5V selectable
Output current 3A
Insulation degree Between base and output terminal ≥20MΩ/500V DC
Between base and power cord ≥30MΩ/500V DC
Display accuracy 3 & 1/2 digits LED display ≤±0.5%+2d

6
This section contains important safety instructions. Read the following before any operation to ensure your
safety and to keep the best condition for the power supplies.
4.1 Safety Symbols
The following symbols may appear in the manual or on the products:
DANGER High Voltage
ATTENTION refer to Manual
Protective Conductor Terminal
(ground) Earth Terminal

7
4.2 Safety Guidelines
Operation to power outlet and power cord: please use polarized power cord and polarized power outlet
for the instrument to ensure the case, output terminal are properly grounded.
To avoid damage, don’t remove the upper case, front or rear panel during operation to the power supply.
Do not touch the upper case or rear panel (heat sink). They are heating bodies and may cause scald.
Operation environment: The power supply should be operated in an environment with good ventilation
and with temperature at 23℃±5℃. Do not operate the power supply in environment with temperature
over 40℃.
Storage: Do not place any other instruments or inflammables on the power supply.
Abnormal operation: Do not apply high voltage or current which is over the rated voltage to the power
supply. Do not connect the positive and negative output terminals on the front panel continuously in the
way of instant short-circuit.
Grounding: Make sure to connect the input and output terminals to earth during the operation to ensure
your safety and the safety of nearby instruments.

8
Fault shooting: In case of any abnormal phenomenon, please forward the power supply to qualified
technical personnel.
4.3 About AC Input Voltage
The AC input voltage for DPS series is 110V/220V selectable±10%, 50/60Hz. When the power source is
higher than the rated voltage by +10%, please set the output current to 70%~80% of the rating output current to
avoid damage to the power supply.

9
5. PANEL INSTRUCTION
5.1 Front Panel

10
1) POWER : Power switch.
2) Meter V : Displays CH1 output voltage.
3) Meter V : Displays CH2 output voltage.
4) Meter A : Displays CH1 output current.
5) Meter A : Displays CH2 output current.
6) CV indicator: It turns on when CH1 is under constant voltage.
7) CV indicator: It turns on when CH2 is under constant voltage.
8) CC indicator: It turns on when CH1 is under constant current.
9) CC indicator: It turns on when CH2 is under constant current.
10) Sec indicator: It turns on when the unit works under programmable mode.
11) Min indicator: It turns on when the unit works under programmable mode.
12) SAVE1234: Store the settings of voltage, current and time value of programmable point. Short press of the
button recalls the saved settings. Long press of the button stores the settings. The button
background light turns on when recalling or storing. Any changes to recalling or storing settings, the
background light will turn off. All settings (except OUTPUT mode) will be stored. Time value of