Warranty
Maury Microwave hardware products are warranted against defects in materials and workmanship for a
period of one year from date of shipment. During the warranty period, Maury Microwave will, at its option,
either repair or replace products which prove to be defective.
Maury Microwave software products are warranted against defects in material and workmanship of the
media on which the product is supplied for a period of ninety (90) days from date of shipment. Maury also
warrants that the product shall operate substantially in accordance with published specifications during
the same warranty period. During the warranty period, Maury Microwave will, at its option, either repair or
replace products which prove to be defective. Maury does not warrant that the operation of the product
shall be uninterrupted or error-free.
For warranty service or repair, all products must be returned to Maury Microwave and must be issued a
return authorization number by Maury prior to shipment. Buyer shall prepay shipping charges to Maury.
Obligation is limited to the original Buyer.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by
the Buyer, unauthorized modification or misuse, operation outside of the environmental specifications for
the product, or wear resulting from normal use. No other warranty is expressed or implied. Maury
Microwave specifically disclaims the implied warranties of merchantability and fitness for a particular
purpose.
The remedies provided herein are the Buyer’s sole and exclusive remedies. Maury Microwave shall not
be liable for any direct, indirect, special, incidental, or consequential damages whatsoever (including,
without limitation, damages for loss of business profits, business interruption, loss of business
information, or any other financial loss) arising out of the Buyer’s use of or inability to use the product,
even if Maury or an authorized Maury dealer has been advised of the possibility of such damages.


MT1020-340 (Rev B) 12/11 i
Contents
General Information........................................................................................................1
MT1020B Automated Tuner System Power Distribution Hub.............................................1
Specifications......................................................................................................................1
Accessories Supplied..........................................................................................................1
Installation.......................................................................................................................3
Power Requirements...........................................................................................................3
Ground Requirements.........................................................................................................3
Operational Temperature and Humidity..............................................................................3
Connecting the Devices......................................................................................................3
Operation.........................................................................................................................4
Connectors, Controls and Indicators...................................................................................4
Appendix..........................................................................................................................5
Shipping Package...............................................................................................................5
Data Sheet Resources........................................................................................................6
Attachment (located behind Appendix)
Form No. 278A-12, Declaration of Conformity

ii MT1020-340 (Rev B) 12/11
Tables
Table 1. Safety Symbol Definitions...................................................................................................2
Figures
Figure 1. Power Entry Module with Fuse Holder..............................................................................3
Figure 2. Front Panel........................................................................................................................4
Figure 3. Rear Panel ........................................................................................................................4
Figure A 1. Packaging Kit.................................................................................................................5

MT1020-340 (Rev B) 12/11 1
General Information
MT1020B Automated Tuner System Power Distribution Hub
The MT1020B Automated Tuner System Power Distribution Hub is designed to provide power and interface
control for the Maury USB series of automated mechanical tuners. As many as four units may be controlled
through this device. Connection to the host computer is made via a standard USB interface.
Specifications
USB Interface...................................USB 1.1 and USB 2.0 compatible
Power Requirements........................ 100 to 264 VAC @ 47 to 63 Hz, 3 Amps
Mains supply voltage fluctuations not exceeding ±10% of the nominal
voltage. Transient over voltages according to over voltage category II
Output Power ................................... +5 VDC @ 5 Amps
+24 VDC @ 3.4 Amps
USB Power....................................... +5 VDC @ 500 mA per port
Environmental .................................. Indoor use only
Relative humidity, 90% non-condensing
Altitude up to 2000 meters
Pollution degree 2
Accessories Supplied
Qty Part No. Description
1 499-F-173-21 Spare fuse (5x20 mm, 3.1 A, slow-blow)
1 499-C-722 USB cable assembly
1 499-C-082 Power cord for 115 VAC (USA)
or 499-C-469 Power cord for 230 VAC (Europe, CE certified)
or 499-C-718 Power cord (China, CCC certified)

2MT1020-340 (Rev B) 12/11