Merlin M2000PE Manuale utente

05/04
1
Toll free helpline
Please have your serial number and
model name available before calling.
Australia 1800 638 234
New Zealand 0800 653 667
United Kingdom 0800 073 0112
www.merlingo.com
Installation instructions
remote control openers
security at your fingertips
M2000PE
access controller for two doors

05/04
2
Important safety instructions
These warnings are an integral and essential part of the product, and must be delivered to
the user. Read them carefully; they provide important installation, operating, and mainte-
nance instructions. Keep this form and give it to any persons who may use the system in the
future. Incorrect installation or improper use of the product may cause serious danger.
Installation instructions
Installation must be performed by a qualified professional and must observe all local, state,
national and European regulations.
Before starting installation, make sure that the product is in perfect condition.
Laying, electrical connections, and adjustments must be done to “Industry Standards”.
Packing materials (cardboard, plastic, polystyrene, etc.) are potentially dangerous. They must
be disposed of properly and kept out of the reach of children
Do not install the product in an explosive environment or in an area disturbed by electro-
magnetic fields.
The presence of gas or inflammable fumes is a serious safety hazard.
Provide an over-voltage protection, mains/knife switch and/or differential on the power
network that is suitable for the product and conforming to current standards.
The manufacturer declines any and all liability if any incompatible devices and/or compo-
nents are installed that compromise the integrity, safety, and operation of the product.
Only original spares must be used for repair or replacement of parts.
The installer must supply all information regarding the operation, maintenance, and use of
individual components and of the system as a whole.
Maintenance
To guarantee the efficiency of the product, it is essential that qualified professionals per-
form maintenance at the times and intervals required by the installer, by the manufacturer,
and by current law.
All installation, maintenance, repair and cleaning operations must be documented. The user
must store all such documentation and make it available to competent personnel.
Warning for users
Carefully read the enclosed instructions and documentation.
This product must be used for its intended purpose only. Any other use is improper and
therefore dangerous. The information contained herein and in the enclosed documentation
may be changed without notice, and are in fact provided in an approximate manner for
application of the product. Merlin declines any and all liability in this regard.

05/04
3
Introduction
The M2000PE is an access controller for the operation of two doors.
It has an integrated Merlin high security code hopping radio receiver. It also has two Wiegand
inputs for external readers, and two 9 V dc outputs to power them.
Two output relays, each with a 5-amp capacity, allow direct connection to electric locks.
An enabling link on the relays further allows either output to be controlled by one or two
simultaneous inputs, for selected management of either person plus vehicle or personnel
only.
An anti-pass back option allows for exit control management,
A 4-digit LCD display is used for programming and assigning readers or transmitters to a
total memory capacity of 2000 users. The LCD momentarily displays the assigned code
on each valid access.
Connection to the serial port of a PC running WIN-GT/SYSTEM software is possible
using the INT485C adapter. This allows the remote entering or deletion of either individual
or blocks of serial numbers. Alternatively, the handheld GT/SYSTEM terminal can be used.
Four buttons, with colour ID and the aid of the LCD display, offer easy to use setup, pro-
gramming, and parameter setting.
All settings can be password protected.
The M2000PE is housed in a plastic enclosure suitable for indoor installations and for
DIN rail mounting.
Radio interference
Radio interference can reduce the performance of radio frequency (RF) remote controls.
RF remote controls are required to operate in shared radio frequency bands. Regulations
permit other users to continuously operate higher powered devices such as baby monitors
or wireless headphones in these shared bands. These devices may cause radio interfer-
ence that reduces the performance of your remote control. Switch off interfering devices
if possible.

05/04
4
M2000PE
Port 1
Rolling code
+ serial #
+ button #
Validate rol ling code (RF only)
Validate seri al no (2000 ma x)
Detect passback (if req)
Detect enabling loop
Determine user group (if req)
Activate relay (1-180 sec)
Any prox reader
generatin g
26 or 30-bit
Wiegand data
Or any ISO2 or
37-bit Wiegan d
card reader
MW30
converter
ISO2 or 37-bit Wiegand
30-bit Wiegand
Port 2
Door 2Door 1
NO Enable
loop 2
Manual
control 2
Manual
control 1
NC
Enable
loop 1 NONC
Or any keypad
generatin g
26 or 30-bit
Wiegand data
1 2 3
4 5 6
7 8 9
* 0 #
Any Merlin wireless remote control:
handheld, keyring, wall switch or keypad

05/04
5
Connections
Note Make sure that terminals 4 & 6 and 13 & 15 are bridged if no enabling loop is used.
Whatever bridges these terminals must be Normally Closed in order for each relay to oper-
ate.
When connecting a Merlin aerial to the antenna terminal, cut off the MCX connector and
expose 20 mm of braid. Twist this and connect to the ‘antenna shield’ terminal. Connect the
centre core to the ‘antenna’ terminal. Take care to avoid short circuits from stray strands of
shield wire.
Over-riding pushbuttons or keyswitches connected to terminals 5 & 6 and 14 & 15 must be
Normally Open.
The maximum cable distance to readers is 100 metres.
Relay 2
Relay 2 output NC
Relay 2 output C
Relay 2 output NO
Relay 2 enabling link
Relay 2 activation input
ground
Wiegand input - DATA1
Wiegand input - DATA0
Power to reader: 9V dc
Relay 1
Relay 1 output NC
Relay 1 output C
Relay 1 output NO
Relay 1 enabling link
Relay 1 activation input
ground
Wiegand input - DATA1
Wiegand input - DATA0
Power to reader: 9V dc
green – VAL (validate)
red – INC (increment)
blue – DEC (decrement)
yellow – FUN (function)
RJ-11 connector
to GT/SYSTEM
ground
+12-24 V dc/ac 10%
RS485:A to PC
RS485:B to PC
Antenna shield
Antenna

05/04
6
Programming connections
It is possible to perform all the necessary programming from the front panel of the M2000PE.
However, in some instances, it may be useful to programme it in other ways.
A PC running WIN-GT-SYSTEM software can be connected through an INT485C adapter.
The PC requires a serial port.
The handheld GT/SYSTEM programmer can be connected into the RJ11 port.
INT485C
GT/SYSTEM
PC running WIN-GT-SYSTEM
M2000PE
RS232
10m max RS485
1000m max
RJ11
1000m max

05/04
7
Setup
Note: VAL, DEC, INC, and FUN refer to the green, red, blue and yellow buttons on the
M2000PE.
Channels 1 to 4 correspond to the buttons of the Merlin wireless devices as follows:
Assigning codes to memory
Memory locations range from 0001 – 2000. Any combination of wireless devices, proxim-
ity tags, card readers, or Wiegand keypads can be assigned to these locations. This can be
done by accessing programming mode, selecting which memory space is to be used, and
then assigning the device.
a) Simultaneously press INC & DEC to enter programming mode.
b) Select a free location by scrolling with INC & DEC from 0001 to 2000. A free
location is indicated by decimal points being off.
c) Press wireless device button once (any button), or have the badge read by
reader. The decimal points will switch on e.g. 0.0.0.1.
d) Press VAL to confirm. The decimal points will briefly flash when the assignment
is complete.
e) Repeat steps b) to d) to assign more devices, or simultaneously press INC &
DEC to exit programming mode.
Note that codes can alternatively be assigned in blocks using the F6 function described
later.
Deleting codes from memory
Deleting an assignment from an individual location is described below. Bulk and block
erase options are described later.
a) Simultaneously press INC & DEC to enter programming mode.
b) Scroll using INC & DEC to display the location whose code is to be deleted.
Decimal points will be on, e.g. 1.0.2.3.
c) Press VAL to confirm. The letter C will appear on the left of the display.
d) Press VAL again to confirm deletion. The assigned code will be deleted and the
decimal points will go off, e.g. 1 0 2 3
e) Repeat steps b) to d) to delete more devices, or simultaneously press INC &
DEC to exit programming mode.
ch 2
ch 1
ch 3
H128C
ch 3
ch 2
ch 1
ch 4
M840
ch 2
ch 1
H128C
ch 2
H128C
ch 1
ch 2
M842
ch 1
ch 2
ch 4ch 3
M844

05/04
8
F1, F2: relay 1 setup, relay 2 setup
Relays can be individually programmed to either toggle or operate for a period of 1 –180
seconds
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.
c) Scroll using INC & DEC to display F1 or F2 (relay 1 or relay 2).
d) Press VAL to confirm. The current parameter value will be displayed, e.g. 0002
e) Select the value to be assigned with the scroll keys. If 0000 is set then the relay
states will toggle (bistable operation). If a value of between 0001 & 0180 is set,
then the relay will be energised for that many seconds (monostable operation)
f) Press VAL to confirm. Display will return to function selection.
g) Repeat steps c) to f) for the other relay, or simultaneously press INC & DEC to
exit programming mode.
F3, F4: Radio channel > Relay 1, 2
Functions F3 & F4 assign relays 1 and/or 2 to wireless device button 1, 2, 3, or 4. For
example if you assign F3 & F4 to button 1, both outputs will operate simultaneously from
that button.
The default setting assigns button 1 to operate relay 1 (F3) and button 2 to operate relay 2
(F4).
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.
c) Scroll using INC & DEC to display either F3 or F4 (relay 1 or relay 2).
d) Press VAL to confirm. The current parameter value will be displayed e.g. _CH1
e) Scroll to select the desired radio transmitter channel, i.e. _CH1, _CH2, _CH3,
_CH4
f) Press VAL to confirm. Display will return to function selection.
g) Repeat steps c) to f) for the other relay, or simultaneously press INC & DEC to
exit programming mode.
F5: Password
Password protection can be set if required. If used, the password will be requested on every
access to the programming mode. The password is set by pressing any 6-key combination
of the 4 coloured keys. This results in 4096 possible passwords.
It is strongly recommended to write down the combination prior to setting. If a password is
forgotten or lost then the M2000PE must be returned to the supplier. Note that all memory
will be cleared and so all card and wireless device assignments will require re-entering.
To enter a password:
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.

05/04
9
c) Scroll using INC & DEC to display F5.
d) Press VAL to confirm. The letter P will appear on the left of the display.
e) Using the 4 coloured keys, enter a total of 6 presses of any combination. E.g.
Enter: yellow, blue, red, green, yellow, and blue. (Be sure you write down the
sequence first.) The letter P will flash each time a digit is entered.
f) A correctly coded sequence will return the display to F5. Note that the se-
quence must be completed within 10 seconds.
g) Simultaneously press INC & DEC to exit programming mode.
A password can only be deleted if it is known.
To delete a password
a) Simultaneously press INC & DEC to enter programming mode. The password
will be requested.
b) Key in password.
c) Press FUN to access the function selection menu.
d) Scroll using INC & DEC to display F5.
e) Press VAL to confirm. The letter P will appear on the left of the display.
f) Wait approximately 10 seconds. Once the display returns to F5 the password
has been deleted.
g) Simultaneously press INC & DEC to exit programming mode.
F6: Block program
Block entry of codes can be performed with sequential prox tags or cards.
Note that Merlin high security code hopping wireless devices can not be entered in this
manner, due to the additional security of the code hopping validation that each device
requires.
The required lower and upper free locations are selected. The lowest serial number card or
tag is assigned to the lower free location and the remaining locations are automatically
filled with the remaining serial numbers.
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.
c) Scroll using INC & DEC to display F6.
d) Press VAL to confirm. The lowest unassigned location will appear on the dis-
play. (Default is 0.001) Note the left decimal point is on, indicating that this
location is the lower bound of the range.
e) If required, scroll using INC & DEC to alter the lowest location to be used, e.g.
0.020
f) Press VAL to confirm. The highest unassigned location will appear on the dis-
play. (Default is 0001.) Note the right decimal point is on, indicating that this
location is the upper bound of the range.
g) Scroll using INC & DEC to display the highest unassigned location, e.g. 0029.

05/04
10
h) Press VAL to confirm. The lower bound will now be displayed again, e.g. 0.020
i) Pass the lowest serial number card or tag through the reader once, e.g. serial
no. 12350. All decimal points will display if the first code is successfully as-
signed, e.g. 0.0.2.0.
j) Press VAL to confirm. Display will return to the function selection menu.
k) Simultaneously press INC & DEC to exit programming mode.
All remaining cards or tags should now be automatically sequentially assigned to locations.
F7: Block erase
To erase a block of codes from memory.
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.
c) Scroll using INC & DEC to display F7.
d) Press VAL to confirm. The lowest required location for deletion will appear on
the display. (Default is 0.001) Note the left decimal point is on, indicating that
this location is the lower bound of the range.
e) If required, scroll using INC & DEC to alter the lowest location to be deleted, e.g.
0.020
f) Press VAL to confirm. The highest location for deletion will appear on the dis-
play. (Default is 0001.) Note the right decimal point is on, indicating that this
location is the upper bound of the range.
g) Scroll using INC & DEC to display the highest location for deletion, e.g. 0029.
h) Press VAL to confirm. The letter C will be displayed.
i) Press VAL again to confirm the block erase. Codes in all locations from the
lower to the upper selection will be deleted. Display will return to the function
selection menu.
j) Simultaneously press INC & DEC to exit programming mode.
F8: Erase all
Codes can be erased from all locations. However this will not affect other stored param-
eters such as relay times or channel assignments.
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.
c) Scroll using INC & DEC to display F8.
d) Press VAL to confirm. The letter C will be displayed.
e) Press VAL again to confirm the bulk erase. Codes in all locations will be deleted.
Display will return to the function selection menu.
f) Simultaneously press INC & DEC to exit programming mode.
F9: Data copy
Codes may be transferred serially in blocks from locations in one M2000PE to the same
Indice
Altri manuali Merlin Telecomando