METREL MD 9880 Introduction
2
Distributor:
METREL d.d.
Ljubljanska cesta 77
1354 Horjul
Slovenia
web site: http://www.metrel.si/
Metrel GmbH
Mess und Prüftechnik
Orchideenstrasse 24
90542 Eckental -Brand
Germany
Internet: http://www.metrel.de/
Metrel UK Ltd.
Test & Measurement
Unit 16, 1st Qtr Business Park
Blenheim Road
Epsom
Surrey
KT19 9QN,
Great Britain
Internet: http://www.metrel.co.uk
© 2019 METREL
Mark on your equipment certifies that this equipment meets the requirements of the EC
(European Community) regulations concerning safety and electromagnetic compatibility.
No part of this publication may be reproduced or utilized in any form or by any means
without permission in writing from METREL.

METREL MD 9880 Contents/ Inhalt
3
Contents/ Inhalt
English
1. Introduction....................................................................................................... 4
2. Safety ............................................................................................................... 5
3. Product description........................................................................................... 7
4. DMM Setup and Measurements..................................................................... 10
5. Thermal camera and DMM operation ............................................................. 14
6. Settings Menu................................................................................................. 17
7. Technical specifications.................................................................................. 21
Deutsch
8. Einführung ...................................................................................................... 25
9. Sicherheit........................................................................................................ 26
10. Produktbeschreibung...................................................................................... 28
11. DMM-Aufbau und -Messungen....................................................................... 31
12. Wärmekamera- und DMM-Betrieb.................................................................. 36
13. Einstellungsmenü ........................................................................................... 39
14. Technische Spezifikationen............................................................................ 43

METREL MD 9880 Introduction
4
1. Introduction
Professional True RMS Industrial Digital Multimeter with built-in thermal camera, with
colour TFT LCD display, providing fast A/D conversion and high accuracy.
Let it be easy to find and solve the problems in equipment, mechanical devices,
installation, buildings and more. Measurements can be done in nearly any
environment due to double moulded plastic housing design.
4000 count 2.4" TFT Color LCD display,
Built-in Thermal camera with Max, Min and Centre crosshair targeting,
50Hz frame rate for thermal images,
DC, AC, AC+DC TRMS Voltage,
DC, AC,AC+DC TRMS current,
Resistance and continuity test,
Diode test,
Capacitance,
Frequency,
Duty Cycle

METREL MD 9880 Safety
5
2. Safety
This symbol adjacent to another symbol, terminal or operating device
indicates that the operator must refer to an explanation in the User
manual to avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation that
could result in death or serious injury if not avoided.
This CAUTION symbol indicates a potentially hazardous situation that
may result in damage to the product if not avoided.
Terminals with this marking must not be connected to voltage
exceeding 600 V in DC or AC in respect to earth.
Terminals with this marking can be subjected to particularly high
voltages during normal use. For maximum safety, the meter and the
leads should not be handled while these terminals are energized.
Indicates electrical protections with double insulation.
1.
Overvoltage category I
Equipment with CAT I protection is only to be connected to circuits where protection
measures for limiting the transient over-voltages to acceptably low values are
observed.
NOTE:
Examples include protected electronic circuits.
2.
Overvoltage category II
Equipment with CAT II is can be connected to fixed installations with overvoltage
protection in place.
NOTE:
Examples include household, office, and laboratory appliances.

METREL MD 9880 Safety
6
3.
Overvoltage category III
Equipment with CAT Ill can be used as part of fixed installations. It must contain its
own overvoltage protection.
NOTE:
Examples include switches in the fixed installation and some equipment for industrial
use with permanent connection to the fixed installation.
4.
Overvoltage category IV
Equipment with CAT IV is used at installation connection to the network.
NOTE:
Examples include electricity meters and primary over-current protection equipment.
The meter has been designed to be used safely, but must always be operated with
caution. Rules for safe operation are the following.
DO NOT use with voltage or current exceeding the specified maximum.
Input Protection Limits
Function
Maximum Input
Voltage DC or AC
600 VDCRMS / VACRMS
Frequency, Resistance, Capacitance
Duty Cycle, Diode test, Continuity
Current AC or DC
10 A
Surge Protection:6kV peak per IEC 61010
USE EXTREME CAUTION when working with high voltages.
DO NOT measure voltage if voltage on the "COM" input jack exceeds 600V
above earth.
NEVER connect the meter leads across a voltage source while the function switch
is in the current, resistance, or diode mode. Doing so can damage the meter.
ALWAYS discharge filter capacitors in power supplies and disconnect the power
when making resistance or diode tests.
ALWAYS turn off the power and disconnect the test leads before opening the
covers to replace the fuse or batteries.
NEVER operate the meter unless the back cover, the battery, and fuse covers are
in place and fastened securely.
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.

METREL MD 9880 Product description
7
3. Product description
1.
LCD Display
2.
MODE / RANGE button
3.
Thermal mode / flashlight button
4.
Navigation / menu buttons
5.
Rotary switch
6.
Positive (+) probe input jack for
current.
7.
Positive (+) probe input jack for all
inputs except A and mA
8.
COM(-) Probe input jack
9.
Thermal camera lens
10.
Lens cover
11.
Probe slot
12.
Support plate
13.
Work light
14.
USB interface cover lock
The push buttons on the front of the meter activate features that augment the
function selected using the rotary switch, navigate menus or control power to Meter
circuits.

METREL MD 9880 Product description
8
1.
Cursor soft buttons
Use navigational stick to select item in a menu, adjust display contrast, scroll through
information, perform data entry, or enter one of the data modes:
Up navigational button enters Relative zero function; compare new result
to the previous.
Left navigational button enters Maximum function; only save when new
result is higher than previous.
Right navigational button enters Peak mode; fast capture of the highest
value.
2.
Physical buttons
Short press MODE key to change functions within the chosen on the rotary
switch. Long press to switch range.
Short press the IT key to switch between IR+DMM or DMM modes. Long press
to turn the LED flashlight on or off.
Navigational stick. Short press centre for OK/Hold to freeze the present
reading on display. Long press to enter main menu.
DMM display:
1.
Indication of Automatic / Manual mode
2.
Indication of the system's time
3.
Indication of battery charge level
4.
Indication of measuring unit
5.
Indication of measuring result
6.
Analogue bar-graph
7.
Indications associated with function keys
8.
Measured temperatures
9.
Emissivity
10.
Temperature unit
11.
IR image

METREL MD 9880 Product description
9
Voltage over 30 V
Warning
Flexible coil
Iron clamps
Relative mode
Rising edge time
AC voltage or current
DC voltage or current
AC+DC voltage or
current
Continuity beeper
Diode function
Resistance
Select a primary measurement function by positioning the rotary switch to one of the
icons around its edge. For each function, the Meter presents a standard display for
that function (range, measurement units and modifiers). Button choices made in one
function do not carry over into another function.
V~
AC voltage measurements
V
DC and AC+DC voltage measurements
HZ %
Frequency and Duty measurements
Ω, CAP,
Resistance, diode test, capacitance and continuity measurements
A
AC, DC and AC+DC amperes measurements
mA
AC, DC and AC+DC milliamperes measurements
µA
AC, DC and AC+DC microamperes measurements up
to 4,000 µA

METREL MD 9880 DMM Setup and Measurements
10
4. DMM Setup and Measurements
CAUTION:
Do not measure DC voltages on a motor while the circuit is being
switched ON or OFF. Large voltage surges may occur that can
damage the meter.
Set the rotary function switch to the VDC position.
Insert the black test lead banana plug into the negative COM
jack.
Insert the red test lead banana plug into the positive V jack.
Read the voltage in the display.
CAUTION:
Do not measure DC voltages on a motor while the circuit is being
switched ON or OFF. Large voltage surges may occur that can
damage the meter.
Set the function switch to the VDC position.
Insert the black test lead banana plug into the negative COM jack. Insert the red
test lead banana plug into the positive V jack.
Press the MODE key to switch the V AC+DC Voltage
function
Read the AC+DC voltage in the display.
WARNING: Risk of electrocution. The probe tips may not
be long enough to contact the live parts inside some
240V outlets for appliances if the contacts are recessed
deep. Therefore, the meter may read 0 on a live outlet.
Make sure the contact is made before assuming no
voltage is present.
CAUTION:
Do not measure DC voltages on a motor while the circuit
is being switched ON or OFF. Large voltage surges may
occur that can damage the meter.
Set the rotary function switch to the VAC position.
Insert the black test lead banana plug into the negative COM jack. Insert red test
lead banana plug into the positive V jack.
Read the voltage in the main display
Set the rotary function switch to the Hz% position.
Insert the black test lead banana plug into the negative COM jack. Insert the red
Figure 1: Measuring
voltage, resistance,
capacitance, frequency
and diode
Figure 2: Screen when
measuring AC and DC voltage
Indice
Lingue:
Altri manuali METREL Multimetro

METREL
METREL MD 9035 Manuale utente

METREL
METREL MD 9220 Manuale utente

METREL
METREL MD 9020 Manuale utente

METREL
METREL MD 9040 Manuale utente

METREL
METREL MD 9070 Manuale utente

METREL
METREL EurotestCOMBO MI 3125 Manuale utente

METREL
METREL MD 9030 Manuale utente

METREL
METREL MI 3122 Manuale utente

METREL
METREL MD 9016 Manuale utente

METREL
METREL MD 9010 Manuale utente
Manuali Multimetro popolari di altre marche

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuale utente

PeakTech
PeakTech 4000 Manuale per l'uso e la cura

YOKOGAWA
YOKOGAWA 90050B Manuale utente

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuale utente

Fluke
Fluke 8846A Manuale operativo e di manutenzione

Tempo Communications
Tempo Communications MM200 Manuale utente