WARNING: Carefully read this manual before operating
NOTICE: The manufacturer takes no responsibility for the
consequences of actions not complying with the instructions
given in this manual.
Index

3
© MFC International 2017
• Ensure that this equipment is used only by trained personnel.
• PowermatsshouldonlybeinflatedusingMFCInternationalcontrolequipment.
• Neverexceedtheworkingpressureof12bar.
• EnsurethatPowermatsareprotectedfromhotexhausts.
• Keepclearofloadswhichareunsupportedbychocksduringliftoperations.
• Operatorshouldbepositionedawayfromthedirectionofanticipatedthrust
particularlywhenmakingspacewithpartially-insertedPowermats.
• Neverworkunderaloadwithoutsafetysupports.
• DonotusedeliveryhoseforretrievingorrepositioningPowermats.
• Do not stack Powermats.
• Ensureallgaugesarereadingzerobeforedisconnectinghose.
Standard components
2xPowermats(A).
2x10mDeliveryHosec/wsafetylockcouplings(B).1xDualController/Regulatortype
530/855(C).
1xHighPressureConnectingHosec/wbleedvalve(D).
Optional accessories
CarryingValisefor2xPowermats(notshown).CarryingValiseforDeliveryHose(notshown
C
A
B
D
Warnings
Components
12.0 bar

4
© MFC International 2017
Note: alldimensionsareaccurateto±3%andallweightsareaccurateto±5%.
Delivery Hose (controller to powermat)
10mmI/D,ReinforcedPVCHose.
Max.Workingpressure:16bar@23degrees.11Bar@60degrees
Standardlengthsupplied:10metres
Quickreleasesafetylockcouplingseachend.
High Pressure Hose (cylinder to controller)
6mmI/D,doublewirereinforcedsyntheticrubberhose.
Max.Workingpressure:400Bar
Standardlengthsupplied:450mm
Colour:Black
Technical Data
KS2 KS5 KS8 KS16 KS18 KS23 KS30 KS43 KS49 KS68 KS81 KS97
Product Code
KS02/12 KS05/12 KS08/12 KS16/12 KS18/12 KS23/12 KS30/12 KS43/12 KS49/12 KS68/12 KS81/12 KS97/12
Length (cm) 15 22.5 27 38 40.8 46 52 62 65.8 77.5 84 92
Width (cm) 15 22.5 27 38 40.8 46 52 62 65.8 77.5 84 92
Inated height
(cm)
8 13 16 23 25 28 32 38 41 48 52 57
Deated height
(cm)
2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Maximum lift
(tonne)
257.5 15.6 18.1 23.2 30 43.2 48.8 68.4 80.7 97.2
Air capacity at
12 bar (litres)
4 18 34 100 128 180 268 449 565 906 1151 1518
Weight (kg) 0.5 1.3 1.8 3.6 4.1 5.1 8 12 13.5 14.5 20 23
Max Pressure
(bar)
12 12 12 12 12 12 12 12 12 12 12 12

5
© MFC International 2017
MFC COMBINED CONTROLLER/ REGULATOR TYPE 530/855
TheType530/855CombinedControllerregulatespressureoutputandgivesindependent
control to each cushion.
Theleveractuatedcontrolvalvesarethreepositionalprovidingforinflationordeflation.
Theyaresuppliedwithspringloaded“deadman”automaticreturntoocontrol.TheRelief
Valveisspringloadedwithnitrilerubberseals,re-seatingwithin-10%ofpre-setpressure.
1
5
2
1
4
3
3
1. 12.0BarpanelMountGuage.Lum.Ctd.Dial(airbagpressure).
2. 0-400BarpanelMountedGuage(cylinderpressure).
3. Leveractuatedspoolvalve.
4. Nylonwebadjustablecarrying/handlingshoulderstrap.
5. MFCprod/serialNo.label.
Materials List
W22.3XD20XH15.5cm
Weight:5.54Kgs
12.0

6
© MFC International 2017
• Assesstheweightloadtobelifted,selectsizeofPowermattobeused–Two
Powermatsusedintandemdoublestheliftpotential.Stabilityoftheliftingoperation
shouldbemonitoredthroughout.
• Do not stack powermats.
• InsertthePowermatwellundertheloadtoachievestabilityandmaximum
surfacecontact.
CAUTIONS:
• Avoidcontactwithsharporjaggedsurfacesastheymay
puncturethesurfacecausingthePowermattofail.
• Hotexhaustsshouldbecoveredwithafoldedfireand
heatresistantblanket.Failuretodosomaydamagethesurfaceofthe
Powermat.
• Takeallthenormalprecautionsagainstthedangerof
outbreakoffire,suchaslayingoutchargedlineofhoseorfoambranch
as appropriate.
WARNING: Withanyliftingoperation,safetysupportstructuresareessential.Carrying
outworkunderaloadsupportedonlybyaninflatedairbagisextremely
dangerousandiscontrarytoallsafetyguidelinesandinstructions.
1. ConnectthedeliveryhosesbetweenthePowermatsandcontroller.
Ensuredeliveryhosesarewelllaidoutandnot‘kinked’,maintaininga
clear line to respective Powermats.
2. Connecthigh-pressurehosefromcylindertocentreportonrearof
controller(Max.controllerinletpressureis300bar).
CAUTION:Ensurecontrollerleversarein‘o’positionbeforeopeningairsupply.
3. Commenceinflationbymovingcontrollever(s)toinflateposition.When
therequiredheightormaximumoperatingpressureof12barisreached,
releasetheinflationlever.WhenusingtwoormorePowermats,
balanceairinputbyattentiontocontrollergauges.
4. Onceinflated,donotattempttodisconnectthehosecouplingsfromthe
Powermats.DoingthiswillcausethePowermatstodeflateuncontrollably.
5. Packandblockasliftproceeds,takingcaretoseeblocksareplacedso
that,ifnecessary,theycansupporttheload.
Operational Instructions

7
© MFC International 2017
6. Shouldachangeofcylinderberequired,closethecylindervalve.
Disconnectbymeansofcylinderadaptorhandwheelandreconnectto
chargedcylinder.
7. Afteruse,deflatebyselectingrelevantpositionofcontrollever.Deflationis
thereverseoftheinflateprocedure.
ThefollowingMaintenanceandTestProceduresshouldbeobserved,andcarriedoutby
properlyqualifiedpersonnel.
Periodic Testing / After Operational Use
1. WashdownPowermatsurfacethoroughlywithwarmsoapywater.
2. ExaminesurfaceareathoroughlybeforeInitiallyinflatingthePowermatto
0.5bar.Carryoutafurtherthoroughexaminationandmarkoanycuts
orabrasionswithchalk.Increasethepressureto2.4bar(35psi)andrepeat
thevisualcheck.Allowtostandfor3minutes.
3. Examinemarkedareasandlookforanyfurthercuts,abrasions,andany
obviousdeformityoftheinflatedcushion.Ifthereisevidenceofany
damageordeformity,thepowermatshouldbewithdrawnfromservice.
Itcanthenbereturnedtothesupplierforexpertexaminationifrequired.
4. Shallowsurfacecutsorabrasionsshouldnotaecttheefficiencyofthe
Powermat.Inthecaseofholesorcuts,throughwhichtheinnerfabric
isvisible,theairbagsshouldbewithdrawnfromoperation.IfaPowermat
leaks,itisNOTrepairable.Iftheuserisuncertainabouttheconditionofa
damagedPowermat,itshouldbereturnedtothesupplierforexpert
examination.
5. InflatethePowermatto4bar(58psi)maximumandchecktheinlet
couplingwithsoapywater.Thoroughlywipedrybeforereturningto
storage.
Delivery Hoses
Periodicallyorafteroperationaluse,checkforabrasionmarks.Chargehosetoworking
pressurewithhosedisconnectedfromPowermat,usesoapywatertocheckairholding
integrityofconnections.Tightenloosefittingswherenecessary.
Maintenance & Test Procedures

8
© MFC International 2017
Annually
Annualtesttobecarriedoutbythemanufacturer,orafullyqualifiedcompetentbody.
UK:MFCInternationalLtdhasafacilityfortesting,whichcustomersandbrigade
personnelmayobserve.Alsoavailableisanon-siteservicevehicle,pleasecontactour
servicingdivisionforfurtherinformation.
Overseas:Contactagentforadviceoffacilitiesavailable.
Dual Controller Type 530/855 - Quarterly and after Operational Use
1. Visuallyinspectcontrollerforsignsofdamage.
2. Checkmechanicaloperationofflowcontrollevers.
3. Connectcontrolunittoairsourcebymeansofreduced-pressurehose
fromcylinderordirectlyfromcompressor(maximuminletpressure300
bar).
4. Withcontrolleversinthe“OFF”positionturnonairsupply.Check
integrityofinletsupplyconnections.Connectdeliveryhosesto
controllerbutnottothePowermats.Movecontrolleverstoinflate
position.Checkfunctioningofreliefvalvesbyreferencetodischarge
pressurelineonfaceofgauge.Thereliefvalvesshouldventat12.0bar
+/-10%.
5. Withcontrollerpressurisedcheckforleaks.Aleakisindicatedbya
pressuredecreaseontheAirbagPressureGauge(NOTE:allowthe
pressurereliefvalvestore-seatbeforecheckingforleaks).Ifaleakis
detected,pleasecontacttheservicingauthorityimmediately.
6. Thoroughlywipedownanddrycontrollerbeforestoring.

9
© MFC International 2017
Storage
Powermatsshouldbestoredinaclean,dustfreeenvironmentandinaccordancewithBS
3574whichstates:
• StorageTemperaturebetween10ºCand25ºC.Humiditybelow75%.
• Protectionagainstlight,particularlydirectsunlightorintenseartificiallight
withhighultra-violetcontent.
• Avoidequipmentcapableofgeneratingozonee.g.highvoltageelectrical
equipment.
Storage

10
© MFC International 2017
Questo manuale è adatto per i seguenti modelli
12
Indice
Manuali Sistema di sollevamento popolari di altre marche

Genie
Genie Z-60/34 Manuale utente

Screen Technics
Screen Technics INTERFIT Vertical Up Lift Manuale utente

Mortuary Lift
Mortuary Lift ULTIMATE 1000 Manuale utente

Custom Equipment
Custom Equipment Hy-Brid 3 Series Manuale di programmazione

Custom Equipment
Custom Equipment Hy-Brid Lifts 2 Series Manuale di programmazione

Hy-Brid Lifts
Hy-Brid Lifts HB-P3.6 Manuale di programmazione