●The average power requirement of the RedEdge-MX integrated with a DLS 2 is
4.0W. However, the camera can require instantaneous power of up to 8.0W
during operation for brief periods of time. Ensure the power supply can
reliably source 8.0W during operation while remaining within the operating
voltage range. Operation outside of the specified input voltage range may
result in unreliable operation or damage to the camera.
●The RedEdge-MX contains under-voltage and over-voltage protection circuitry
which nominally applies at 3.8V and 16.0V. However, over the operating
temperature range these cutoff voltages can vary by up to 0.2V. For reliable
operation, ensure the supply voltage remains within the operating input
voltage range at all times over the full range of operating conditions.
●Trigger input: The camera can be triggered either with a rising-edge pulse,
falling edge pulse or a PWM signal (such as is typically used with standard
servos). When using a PWM signal as the trigger, the camera detects a
transition from a “long” PWM to a “short” PWM (or vice-versa depending on
the configuration setup of the camera)
© 2018 MicaSense, Inc. Page 7 of 19