MILUX MCF- E120 Manuale utente

Operating And Installation Instructions
Indoor Fan Specification
(Fan picture is for installing reference only)
Model:
MILUX SALES & SERVICE SDN. BHD.
Head Office: No. 31, Lorong Jala 14/KS10 Off Jalan Telok Gong 42000 Port Klang Selangor Malaysia.
Tel:603-31341254 Fax:603-31341193
Toll Free:1800-88-Milux(64589)
http://www.milux.com.my
MCF- E120 / MCF-E122L
MCF- E220 / MCF-E221L

1
1.Installation must be carried out by a qualified wiring installer.
2. Before Installing the fan turn off the power supply.
3.Use power supply 220-240V/50Hz.
4.When mounting the fan,ensure that the safety cable is loop across the ceiling
mounting hook.
5.The ceiling mounting hook must be able to withhold a min of 35 pounds.
7.Do not place any objects in the path of the blades.
8.When all electrical connection are done,store all wire neatly.
9.Make sure that all screws and connection are tightly screwed and secured.
10.An all‐pole disconnection must be incorporated in the fixed wiring in accordance
with the wiring rules, a all‐pole disconnection incorporated in the fixed wiring is to
be provided.
11.This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
Safety Precaution

2
Supplied Parts
Fig.1 Fig.2
1)Remove the parts from the both side of downrod.(Fig.2)
2)Insert downrod through canopy&yoke cover, Insert the down rod into the motor shaft,
Thread wires and safety cable through downrod,Aligning the down rod holes to the holes of shaft.
Tighten the down rod to motor with the previous bolt、washer、nut and contter pin (Fig.3)
2.Downrod Installation
a
b
c
d
e
1
2
3
4
5
6
7
1
2
3
4
5
6
7
#Qty
Parts
11
Downrod
21
Ceiling canopy
31
Yoke cover
41
Fan motor assembly
53
Fan blade
61
Bottom cover
7
1 set
Balance kit
a. 2
Live wire / Neutral wire
b. 3
Light kit
GX53 globe
a
b
c
d
e
8
Wire nut
c. 7
Flat washer
d. 7
Blade screw
e.
#Qty
Parts
11
Downrod
21
Ceiling canopy
31
Yoke cover
41
Fan motor assembly
53
Fan blade
61
1
7
1 set
Balance kit
a. 2
Live wire / Neutral wire
b. 3
Wire nut
c. 7
Flat washer
d. 7
Blade screw
e.
For without light For with light

3
Fig.3
Fig.4
Fig.5
Fig.2
Downrod Installation
Fig.6
Safety Cable
“J” Hook
Screw
Ceiling
Safety Cable
Bolt
Nut
Cotter pin
Spring Washer
Ceiling
Hook
Pulley
a
3)“U” Hook mounted,Remove the bolt, stop pin,
nut, washer and rubber pulley from the downrod.
(Fig.4)
4)
Place the pulley onto the Hook.(Fig.a)
5)Lift the motor until the bracket hole of the
downrod aligning the pulley hole.Tighten the
downrod to the pulley with the previous bolt、
washer、nut and contter pin.
Pulley
Bolt
Downrod
Nut
Cotter pin
Spring Washer
Bolt
Nut
Cotter pin
Spring Washer
Flat Washer
Bolt
Lead wire
Safety cable
Grounding wire
6)“U” Hook mounted, Lift the fan onto the
mounted hook,until the hanging wheel seat on
the mounted J hook
.(Fig.6)

4
Fig.7
Fig.8
WARNING
!
1) Remove the safety Cable Screw from the downrod bracket.
2) Arrange and tie the Safety Cable as step 2.
3) Firmly screw the Safety Cable onto the downrod.
Safety Cable must be fixed correctly.
May cause injury if ceiling fan drops.
Screw Screw
Safety
Cable
1 2 3
Install Safety Cable
Blades Installation
Blade
Blade screws
Flat washer
1. Insert the blade screws through the flat washer and blade then secure the blade to the motor by
tightening the 3 screws .(Fig.8)
2. Repeat this process to install the other blades to the motor.

5
Fig.9
Fig.10
Light Kit Installation
For without light:
For with light:
1. Install the bottom cover to the shaft by rotating it clockwise Fig.9
1. Remove the 4 light kit screws from switch housing.
2. Connect the quick connector,and then put them into the switch housing.
3. Attached the light kit to switch housing and align the screw holes,
then secure light kit with 4 light kit screws.
4. Install the globe.
Connector
Switch housing
Light kit
Light kit screws
Globe

6
Fig.11
Fig.12
Fig.13
Electrical Wiring Connection
1. Before Installing the fan turn off the power supply.
2. All electrical connections must be in accordance with local and national electrical code standards.
If you are unfamiliar with proper electrical wiring connections, obtain the services from a qualified
electrician.
3. Take out the two pieces of lead wires from the screws bag and connect the wire to the fan.(Fig.11)
4. Connect the fan wire to the house’s supply wire. Diagram shows a complete assembly of the ceiling fan.
(Fig.12 & Fig.13)
5. Finally,When the connection is completed,Raise the Canopy and tighten it with the Set Screw.
(Supply leads accommodated in the canopy)
Live wire
Neutral wire
Grounding wire Red(L)
Black(N)
Canopy
Ceiling
N
L
Live wire
Neutral wire
Earth wire
RED----------LIVE WIRE
BLACK------NEUTRAL WIRE
YELLOW GREEN -----GROUND WIRE
240VAC/50Hz
Power Supply
Earth wire
Ceiling Fan

7
Maintenance
Due to fan’s natural movement, connections may get loose after a period of usage.
To ensure a proper and safety usage,We highly recommend to inspect and tighten all connections
every 6 months.
CLEANING
Clean your fan periodically to prolong its new appearance. Basic cleaning procedures are as follows:
1.Use only lukewarm water. Do not use detergent, corrosive or acidic solution.
2.Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will
scratch the surface.
3.Apply a thin coat of furniture polish to the wooden blades to protect and enhance the appearance.
4.To cover small scratches, apply a light coat of shoe polish over it.
5.There is no need to lubricate the fan.
Troubleshooting
Check on the following before lodging a service report
SYMPTOM PROBLEM SOLUTION
Fan not moving 1.Main cables not connected 1.Check main and branch circuit
Breakers or fuse
2.Wire connection loose 2.Check the line wires connections
to the fan and switch housing
Fan noisy 1.Housing screws are loose 1.Tighten all screws
2.Wire and nut connections 2.Neatly separate and store the wire
rattles against each other connections from the nut
3.Canopy touches the ceiling 3.Check to ensure the canopy is not
touching or too close to the
Ceiling
Remote control 1.Remote and receiver code 1.Check that the codes are exactly
Not working different the same
2.Battery not installed 2.Install the remote control battery
3.Weak battery 3.Change a new battery

8
Customer Service Center
If you need any technical assistance or to report a fault, please contact
our customer service center at:
MILUX SALES & SERVICE SDN. BHD.(302263-X)
No. 31, Lorong Jala 14/KS10 Off
Jalan Telok Gong 42000 Port Klang Selangor Malaysia.
Tel:603-31341254
Toll Free:1800-88-Milux(64589)
Service Fax: 603-31341193
Website:
www.milux.com.my
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali MILUX Fan