Minarik AC100 SERIES Manuale utente

Variable Speed AC Motor Drives
EPM Programmer
OOppeerraattiioonnMMaannuuaall


1
TABLE OF CONTENTS
1.0 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.1 PRODUCTS COVERED IN THIS MANUAL . . . . . . . . . . . . . . . . . . .2
1.2 PRODUCT CHANGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.3 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.4 RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.5 CUSTOMER MODIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.0 OVERVIEW OF THE EPM PROGRAMMER . . . . . . . . . . . . . . . . .4
3.0 POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.0 PHYSICAL LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.0 USING THE EPM PROGRAMMER . . . . . . . . . . . . . . . . . . . . . . . . .6
5.1 TURNING THE EPM PROGRAMMER ON AND OFF . . . . . . . . . . . .6
5.2 THE MAIN MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5.2.1 MASTER TO EPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.2.2 COMPUTER TO EPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
5.2.3 FILE TO EPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
5.2.4 EDIT DATA FILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
5.2.5 CREATE NEW FILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
5.2.6 DELETE DATA FILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
5.2.7 LOAD CNFG EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
5.2.8 LCD CONTRAST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
5.2.9 MISC INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
6.0 LCD BACKLIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
7.0 WARNING MESSAGES & TROUBLESHOOTING . . . . . . . . . . .31

1.0 GENERAL
1.1 PRODUCTS COVERED IN THIS MANUAL
This instruction manual covers the Minarik EPM Programmer which is used with the Minarik
AC100 and AC200 Series Variable Frequency Drive. The EPM Programmer can also interface
with Minarik’s TechLink serial communications software. Please refer to the instruction
manuals provided with the AC100 and AC200 drives and TechLink software for more
information.
1.2 PRODUCT CHANGES
Minarik Corporation reserves the right to discontinue or make modifications to the design of
its product without prior notice, and holds no obligation to make modifications to products sold
previously. Minarik Corporation also holds no liability for losses of any kind which may result
from this action.
1.3 WARRANTY
Minarik Corporation warrants the EPM Programmer to be free of defects in material and
workmanship for a period of twelve months from the date of sale. If an EPM Programmer,
which under normal use, becomes defective within the state warranty time period, contact
Minarik’s Service Department for instructions on obtaining a warranty replacement unit.
Minarik Corporation reserves the right to make the final determination as to the validity of a
warranty claim and sole obligation is to repair or replace only the components which have been
rendered defective due to faulty material or workmanship. No warranty claim will be accepted
for components which have been damaged due to mishandling, unauthorized repair and/or
alteration of the product, operation in excess of design specifications or other misuse, or
improper maintenance. Minarik Corporation makes no warranty that its products are
compatible with any other equipment (other than those stated herein), or any specific
application to which they may be applied, and shall not be held liable for any other
consequential damage or injury arising from the use of its products.
This warranty is in lieu of all other warranties, expressed or implied. No other person,
firm or corporation is authorized to assume, for Minarik Corporation, any other liability
in connection with the demonstration or sale of its products.
1.4 RECEIVING
Inspect all cartons for damage which may have occurred during shipping. Carefully unpack
equipment and inspect thoroughly for damage or shortage. Report any damage to carrier
and/or shortages to supplier. All major components and connections should be examined for
damage and tightness, with special attention given to PC boards, plugs, knobs and switches.
2

1.5 CUSTOMER MODIFICATION
Minarik Corporation, its sales representatives and distributors, welcome the opportunity to
assist our customers in applying our products. Many customizing options are available to aid
in this function. Minarik Corporation cannot assume responsibility for any modifications not
authorized by its engineering department.
3

4
2.0 OVERVIEW OF THE EPM PROGRAMMER
The EPM Programmer is used to configure the Electronic Programming Modules (EPMs)
included with the AC100 and AC200 Series drives. The EPM stores the settings that determine
how the drive will operate.
The EPM has two separate “storage areas” for parameter settings. One is the User Settings
area, and the other is the OEM Defaults area. The parameters in the User Settings area can be
accessed and changed using the drive’s buttons or Minarik’s TechLink software, but the OEM
Defaults area cannot be accessed without the EPM Programmer. The settings in the OEM
Defaults area can only be changed by copying new parameter settings into the EPM using the
EPM Programmer.
The AC100 and AC200 drives can be programmed to operate according to either the User
Settings or the OEM Defaults (refer to Parameter 48 in the AC100 or AC200 Series Installation
and Operation Manual).
If the drive is programmed to operate according to the User Settings (also called User mode;
done by setting Parameter 48 to “01”), the parameters can be changed by the user (using the
buttons on the front of the drive or TechLink software). The new parameter values are then
stored in the User Settings area of the EPM. In User mode, the user can program and
reprogram the drive to suit any application.
If the drive is programmed to operate according to the OEM Defaults (also called OEM mode;
done by setting Parameter 48 to “02”), however, the user cannot change the parameter settings
stored in the OEM Defaults area of the EPM. In this mode, the parameter values have already
been set to suit a particular application, and the end-user is prevented from changing them.
The EPM Programmer allows the User Settings and the OEM Defaults within the EPM to be
programmed to the desired values. The EPM Programmer can create and store multiple
parameter data files, and can also be interfaced with Minarik’s TechLink serial
communications software in order to load data files stored in a computer or on diskette. Once
a data file is selected, it can be copied to an EPM in about two seconds.
The OEM Defaults area of the EPM can also store a filename to identify the OEM data. This
makes it easy to keep track of “master” EPMs and to verify that the EPM contains the correct
data file to match the application.
NOTE: Please refer to the AC100 or AC200 Series Installation and Operation Manual
(Section 13.2 and Parameter 48 in Section 15.0) for more information on the Electronic
Programming Module (EPM).

5
4.0 PHYSICAL LAYOUT
Below is a diagram of the EPM Programmer which identifies the different parts and features
of the product.
3.0 POWER REQUIREMENTS
The EPM Programmer will operate on four (4) D-size batteries, which are included and already
installed in the unit. The unit also has a jack for use with an AC power adapter (Radio Shack
model 273-1454D or equivalent.

6
5.0 USING THE EPM PROGRAMMER
5.1 TURNING THE EPM PROGRAMMER ON AND OFF
This display indicates what parameter
version the EPM Programmer is
configured for. The example version
is “309”.
This display indicates the parameter
version of the MASTER EPM (if
installed). The example version is
“309”.
This display indicates the filename of
the MASTER EPM (if installed). The
example name is “MINARK1_”.
This display shows the last Main
Menu item that was selected. The
example display is MASTER TO
EPM.

7
If a MASTER EPM is not installed in the MASTER AND CONFIGURATION PORT when
the unit is turned on, the display cannot show the parameter version and file name of the
MASTER EPM, so MASTER MISSING! is displayed.
This display indicates that an EPM is
not installed in the MASTER AND
CONFIGURATION PORT.
This display shows the last Main
Menu item that was selected. The
example display is EDIT DATA FILE.
Press the OFF key to turn off the EPM Programmer. The LCD display will read SHUTDOWN
IN 5SEC and the seconds will countdown to 0, at which time the display will go black,
indicating that the unit is off.
NOTE: If any keys (except the OFF key) is pressed during SHUTDOWN, the countdown will
stop and the EPM Programmer will be activated again.

5.2 THE MAIN MENU
Use the MENU key to scroll through the Main Menu items described in the table below.
Following the table is a description and step-by-step procedure for performing each function.
MAIN MENU
FUNCTION DESCRIPTION
MASTER TO EPM Copies the data from a MASTER EPM to a target EPM.
COMPUTER TO EPM Copies a data file downloaded from a computer to a target EPM.
FILE TO EPM Copies a data file stored in the EPM Programmer to a target EPM.
EDIT DATA FILE Edit a data file that is stored in the EPM Programmer. In order to
edit a stored data file, the configuration version of the EPM
Programmer must match the parameter version of the data file.
CREATE NEW FILE Create a new data file to be stored in the EPM Programmer.
DELETE DATA FILE Erase a data file that is stored in the EPM Programmer.
LOAD CNFG EEPROM Load Configuration Version: Configures the EPM Programmer to
allow editing of data files with different parameter versions.
Requires special Configuration EPMs. Consult the factory.
LCD CONTRAST Changes the contrast of the LCD display to optimize viewing angle.
MISC INFORMATION Displays the Software Version, Configuration Version, Number of
stored Data Files, Battery Voltage, and Password.
Altri manuali per AC100 SERIES
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Minarik Controllori

Minarik
Minarik MM23001C Manuale utente

Minarik
Minarik AC100 SERIES Manuale utente

Minarik
Minarik PCM3 Manuale utente

Minarik
Minarik MAC Series Manuale utente

Minarik
Minarik PCM23001A Manuale utente

Minarik
Minarik MAC Series Manuale utente

Minarik
Minarik AC200 SERIES Manuale utente

Minarik
Minarik MM311U Manuale utente