Minarik MAC Series Manuale utente

USER’S MANUAL
Models:
MAC05–D240AC
MAC08–D240AC
MAC05–D240AC-PCM
MAC08–D240AC-PCM
Variable-frequency drives for 3-phase AC motors
MAC Series
250-0275 rev2.qxd 3/9/01 10:36 AM Page a

Copyright 2001 by
Minarik Corporation
All rights reserved. No part of this manual may be reproduced or transmitted in any
form without written permission from Minarik Corporation. The information and
technical data in this manual are subject to change without notice. Minarik
Corporation and its Divisions make no warranty of any kind with respect to this
material, including, but not limited to, the implied warranties of its merchantability
and fitness for a given purpose. Minarik Corporation and its Divisions assume no
responsibility for any errors that may appear in this manual and make no
commitment to update or to keep current the information in this manual.
Printed in the United States of America.
250-0275 rev2.qxd 3/9/01 10:36 AM Page b

Safety Warnings
•This symbol denotes an important safety tip or warning.
Please read these instructions carefully before performing
any of the procedures contained in this manual.
•DO NOT INSTALL, REMOVE, OR REWIRE THIS
EQUIPMENT WITH POWER APPLIED. Have a qualified
electrical technician install, adjust and service this equipment.
Follow the National Electrical Code and all other applicable
electrical and safety codes, including the provisions of the
Occupational Safety and Health Act (OSHA), when installing
equipment.
•Reduce the chance of an electrical fire, shock, or explosion by
proper grounding, over-current protection, thermal protection,
and enclosure. Follow sound maintenance procedures.
i
It is possible for a drive to run at full speed as a result of
a component failure. Minarik strongly recommends the
installation of a master switch in the main power input to
stop the drive in an emergency.
Circuit potentials are at 115 VAC or 230 VAC above earth
ground. Avoid direct contact with the printed circuit board or
with circuit elements to prevent the risk of serious injury or
fatality. Use a non-metallic screwdriver for adjusting the
calibration trimpots. Use approved personal protective
equipment and insulated tools if working on this drive with
power applied.
250-0275 rev2.qxd 3/9/01 10:36 AM Page i

Specifications 1
Dimensions 2
Installation 3
Mounting ...................................................3
Wiring .....................................................4
Shielding guidelines . . . ......................................5
Isolation (-PCM drives only) . ...................................6
Fusing ....................................................6
Heat sinking ................................................6
Speed adjust potentiometer .....................................7
Cage-clamp terminals . . . ......................................8
Connections . ................................................9
Power and fuse connections .................................10
Motor connections . . . . . . ..................................13
Three-phase motors . . . . . . .................................15
Operation 17
Voltage doubler .............................................18
To enable voltage doubling: .................................19
Before applying power . . . . . . .................................20
Startup ....................................................21
To reverse motor direction: ..................................22
Starting and stopping methods .................................23
Braking . . . ..............................................23
To coast the motor to a stop without disconnecting power: ..........23
I²T trip operation (class 10 characteristics) ......................24
Line starting and line stopping ...............................24
Decelerate to minimum speed ...............................25
Decelerate to minimum with DC injection braking .................26
Drive thermal protection ......................................28
ii
Contents
250-0275 rev2.qxd 3/9/01 10:36 AM Page ii

Thermal protection of the motor ..............................28
Calibration 30
Calibration Procedure Setup for 60 Hz Motors (See Figure 12): .........34
MINIMUM SPEED (MIN SPD) ...............................36
MAXIMUM SPEED (MAX SPD) ...............................36
CURRENT LIMIT (I LIMIT) ..................................36
SLIP COMPENSATION (SLIP COMP) .........................37
ACCELERATION/DECELERATION (ACCEL/DECEL) ..............37
Torque Boost Adjustment ...................................38
Application Notes 40
Thermal Protection Switch Installation ............................40
Independent adjustable speeds with .............................41
FWD-REV switch ...........................................41
RUN/JOG switch ............................................42
Single speed potentiometer control of multiple motors ................43
Reversing . . . ..............................................44
Voltage follower ............................................45
Troubleshooting 46
Before troubleshooting . . . . . . .................................46
Diagnostic LEDs ............................................47
POWER ON (green) . . . . . . .................................47
FAULT (red) ...............................................
TRIP I²T (red) . . ............................................
REV (amber) ...............................................
FWD (amber) . . ............................................
TQ LIM (red) ............................................48
Clearing LED fault indications ..................................52
Replacement Parts ..........................................58
Unconditional Warranty inside back cover
iiiTable of Contents
250-0275 rev2.qxd 3/9/01 10:36 AM Page iii

Figure 1. Dimensions . . . . . . ....................................2
Figure 2. Speed Adjust Potentiometer ..............................7
Figure 3. Cage-Clamp Terminal ...................................8
Figure 4. Power and Fuse Connections ............................10
Figure 5. Signal and Optional Switch Connections ....................12
Figure 6. Motor Connections for Single-Phase Operation ..............14
Figure 7. Motor Connections for Three-Phase Motors .................16
Figure 8. Voltage Doubler Terminals ..............................19
Figure 9. Run/Decelerate to Minimum Speed Switch ..................25
Figure 10. RUN-BRAKE switch with optional ENABLE-DISABLE Switch ....27
Figure 11. Thermal Overload Switch with Optional Enable/Disable Switch . . .29
Figure 12. Calibration Trimpot Layout ..............................31
Figure 13. DIP Switch Layout and Initial Settings ......................32
Figure 14. Carrier Frequency Mode DIP Switch Layout .................35
Figure 15. Accel Torque Boost DIP Switch Setting .....................39
Figure 16. Thermal Overload Protection Switch Installation ..............40
Figure 17. Thermal Overload Protection Switch Installation
With Optional Enable/Disable Switch .......................40
Figure 18. Independent Adjustable Speeds ..........................41
Figure 19. RUN/JOG Switch . . . ..................................42
Figure 20. Single Speed Potentiometer Control of Multiple Motors .........43
Figure 21. Reversing Circuit Connection ............................44
Figure 22. Voltage Follower Connections ............................45
Figure 23. Diagnostic LED Layout .................................49
iv
Illustrations
250-0275 rev2.qxd 3/9/01 10:36 AM Page iv

Table 1. Motor Phase DIP Switch Settings .........................15
Table 2. Voltage Doubler Configuration ...........................19
Table 3. Max Frequency DIPSwitch Settings .......................33
Table 4. Carrier Frequency DIPSwitch Settings .....................35
Table 5. Accel Torque Boost DIP Switch Settings ....................39
Table 6. Replacement Parts ...................................58
v
Tables
250-0275 rev2.qxd 3/9/01 10:36 AM Page v

vi
*Actual minimum frequency will depend on motor type and the load to which it is
connected.
General Information
Minarik MAC Series drives are voltage-vector-controlled,
microprocessor-based, variable-frequency AC motor drives. With
a 115 or 230 VAC, 50/60 Hz, single-phase input, MAC drives are
factory calibrated for an output of 0* to 60 Hz. They will operate
any 1 HP or smaller, 115- or 208/230-volt, three-phase AC
induction motor through a speed range of zero* through
nameplate speed. They can be user calibrated for 0* through 400
Hz output.
Using proprietary power-control circuitry, the MAC can also
double the input line voltage. This allows users to plug the MAC
into a 115 VAC line, but control a 208/230 VAC motor.
Although MAC inverters can operate over a 100:1 speed range,
most motors will operate over a 10:1 speed range with constant
torque at 0* to 60 Hz and constant horsepower above 60 Hz.
(Inverter-duty motors may operate satisfactorily over a 20:1 speed
range.) Some motors can be satisfactorily operated at speeds as
low as 100 rpm (speed range 25:1). Below 100 rpm, some
motors may show signs of “stepping” or “cogging”, or they may
run warmer.
250-0275 rev2.qxd 3/9/01 10:36 AM Page vi

†
In silent mode.
viiGeneral Information
The MAC carrier frequency is true 16.5 kHz.†Many AC drive
manufacturers count the leading and trailing edge of the
modulated signal, thereby doubling the published carrier
frequency; however, their fundamental frequency is only half
(8 kHz in this case). By this method, the MAC’s carrier
frequency would be 33 kHz. The MAC is one of the only drives
on the market with truly silent operation.
MAC Series drives feature solid-state reversing with adjustable
acceleration and deceleration. They also feature adjustable
current limit and I²T class 10 current trip to protect the motor, the
control and the driven machine from damage caused by motor
overload or machine jamming. The MAC may also interface with
motor thermal protection through the enable circuit.
Many 3-phase inverter manufacturers claim that they can run
single-phase motors effectively. This is normally accomplished
by wiring only 2 phases; however, this primitive method may
cause instabilities due to the lack of feedback from one of the
motor connections. Furthermore, motor torque will be reduced
considerably because the phases are still 120º apart. The MAC
can efficiently operate a single-phase motor because the ASIC
changes the phase shift to 90º in order to develop maximum
torque.
250-0275 rev2.qxd 3/9/01 10:36 AM Page vii

Caution should be taken when operating fan-cooled motors
at low speeds because their fans may not move sufficient air
to properly cool the motor. Minarik recommends “inverter-
duty” motors when the speed range is beyond 10:1.
viii General Information
The following motor types MAY NOT be used:
• Split phase
• Capacitor start
• Repulsion induction
• Series Universal AC/DC
• Any motor with starting switch (centrifugal or relay) and/or
separate starting winding.
The MAC is very efficient when the two (2) torque boost settings
are properly adjusted; the accel torque boost is applied only
during acceleration. Other drives, with only one torque boost
setting, can cause motor overheating by applying too much during
steady-state operating conditions.
IMPORTANT INFORMATION
In addition to standard 3-phase induction motors, the following
motor types may be used with the MAC:
• Permanent split capacitor (PSC)
• Shaded pole
• AC synchronous
• AC stepping: 28.8, 72 and 200-RPM type.
250-0275 rev2.qxd 3/9/01 10:36 AM Page viii
Altri manuali per MAC Series
1
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Minarik Controllori

Minarik
Minarik PCM23001A Manuale utente

Minarik
Minarik MM311U Manuale utente

Minarik
Minarik AC100 SERIES Manuale utente

Minarik
Minarik AC100 SERIES Manuale utente

Minarik
Minarik PCM3 Manuale utente

Minarik
Minarik MAC Series Manuale utente

Minarik
Minarik AC200 SERIES Manuale utente

Minarik
Minarik MM23001C Manuale utente