MSA Chillgard 5000 Manuale utente

MSAsafety.com
Operating Manual
Chillgard 5000 Remote Display
Order No.: 10214065/01
CR 800000043779

1000 Cranberry Woods Drive
Cranberry Township, PA 16066
USA
Phone 1-800-MSA-2222
Fax 1-800-967-0398
For your local MSA contacts please go to our website www.MSAsafety.com
© MSA 2020. All rights reserved
WARNING!
Read this manual carefully before using the device. The device will perform as designed only if it is used and
maintained in accordance with the manufacturer's instructions. Otherwise, it could fail to perform as
designed and persons who rely on this device for their safety could sustain serious personal injury or death.
The warranties made by MSA with respect to the product are voided if the product is not installed and used
in accordance with the instructions in this manual. Please protect yourself and your employees by following
the instructions.
Please read and observe the WARNINGS and CAUTIONS inside.
WARNING!
Make sure any personnel who will be installing, using, or maintaining this device have access to the user
manual. If electronic access to the user manual (through the supplied Chillgard 5000 CD or MSA website)
is not possible, print a copy of the manual and keep it in an accessible location near the device.
Failure to obey the following guidelines and/or incorrect installation, operation, servicing, or maintenance of
the device can cause incorrect operation of the device. Personnel who rely on this product for their safety
can sustain serious personal injury or death.

3
Chillgard 5000 Remote Display
US
Contents
1 MSA Permanent Instrument Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Exclusive Remedy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Exclusion of Consequential Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.4 Liability Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 Identifying Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Connection to the Chillgard 5000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.1 Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Receiving, Unpacking, and Inspecting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.3 Mounting Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.4 Wiring and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.5 Electrical Power Supply Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 Initial Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.1 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2 Attaching a Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.2.1 Wiring the Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.2.2 Testing the Functionality of the Strobe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7 Troubleshooting Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
9.1 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
9.2 Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

4
MSA Permanent Instrument Warranty
Chillgard 5000 Remote Display
US
1 MSA Permanent Instrument Warranty
1.1 Warranty
MSA, the Safety Company warrants that these products will be free from mechanical defect or faulty
workmanship for a period of two (2) years from the date of delivery, provided it is maintained and used
in accordance with MSA's instructions and/or recommendations.
This warranty does not apply to expendable or consumable parts whose normal life expectancy is less
than one (1) year, such as, but not limited to, nonrechargeable batteries, filament units, filter, lamps,
fuses, etc. MSA shall be released from all obligations under this warranty in the event that repairs or
modifications are made by persons other than its own or authorized service personnel or if the
warranty claim results from physical abuse or misuse of the product. No agent, employee, or repre-
sentative of MSA has any authority to bind MSA to any affirmation, representation, or warranty
concerning the goods sold under this contract. MSA makes no warranty concerning components or
accessories not manufactured by MSA, but will pass on to the Purchaser all warranties of manufac-
turers of such components.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STAT-
UTORY, AND IS STRICTLY LIMITED TO THE TERMS HEREOF. SELLER SPECIFICALLY
DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR
PURPOSE.
1.2 Exclusive Remedy
It is expressly agreed that the Purchaser's sole and exclusive remedy for breach of the above
warranty, for any tortious conduct of the Seller, or for any other cause of action, shall be the repair and/
or replacement at the Seller's option of any equipment or parts thereof, which after examination by the
Seller is proven to be defective. Replacement equipment and/or parts will be provided at no cost to
the Purchaser, F.O.B. Seller's Plant. Failure of the Seller to successfully repair any nonconforming
product shall not cause the remedy established hereby to fail of its essential purpose.
1.3 Exclusion of Consequential Damage
The Purchaser specifically understands and agrees that under no circumstances will the Seller be
liable to the Purchaser for economic, special, incidental, or consequential damages or losses of any
kind whatsoever, including but not limited to, loss of anticipated profits and any other loss caused by
reason of nonoperation of the goods. This exclusion is applicable to claims for breach of warranty,
tortious conduct, or any other cause of action against the Seller.
1.4 Liability Information
MSA accepts no liability in cases where the device has been used inappropriately or not as intended.
The selection and use of the device are the exclusive responsibility of the individual operator. Product
liability claims, warranties, and guarantees made by MSA with respect to the device are voided if the
device is not operated, serviced, and/or maintained in accordance with the instructions in this manual.
The warranties made by MSA with respect to the product are voided if the product is not used and
serviced in accordance with the instructions in this manual. Please protect yourself and others by
following them. We encourage our customers to write or call regarding this equipment prior to use or
for any additional information relative to use or repairs.

5
Warnings and Cautions
Chillgard 5000 Remote Display
US
2 Warnings and Cautions
The Chillgard 5000 Remote Display, hereafter also referred to as "the device", is an information
module intended for indoor use in front of mechanical equipment rooms or commercial spaces where
refrigerant equipment, such as centrifugal chillers, is used. The device is specified to support compli-
ance with federal, state, and local safety codes that govern emissions.
WARNING!
Install, operate, and maintain the device in strict accordance with its labels, cautions, warnings,
instructions, and stated limitations.
For any maintenance procedure provided in this manual, use only genuine MSA replacement parts.
Repair or alteration of the Chillgard 5000 system beyond the scope of these maintenance instructions
or by anyone other than authorized MSA service personnel can cause incorrect operation of the
device. For a list of approved parts and how to order them, refer to Section 9 "Ordering Information".
The device is intended for indoor use only. Do not use the device for outdoor applications.
Never operate the device without a connection to positive ground. Failure to connect the device to
positive ground can result in electrical shock. Electrical shock can cause damage to the device and
injury to personnel.
Make sure the device is not located in areas that contain a flammable mixture of gas and air. Other-
wise, an explosion can occur.
The device is not intrinsically safe. Do not use the device in areas classified as hazardous or locations
where explosive concentrations of combustible gases or vapors can occur.
Failure to follow these warnings can result in serious bodily injury or death.
WARNING!
Make sure the device is installed in a clean, dry area that is protected from vibration, including but not
limited to a chiller, and heat sources.
Do not paint the device. Paint deposits can prevent correct operation of the device.
Avoid any installation where condensation can collect. Condensation can enter the unit and cause
electrical disturbance.
Install a circuit breaker for the incoming power connections of the device. Put the circuit breaker in a
location that is easy to access and near the device. Clearly mark the circuit breaker as the discon-
necting unit for the device.
Failure to follow these warnings can result in serious bodily injury or death.

6
Description
Chillgard 5000 Remote Display
US
3 Description
The Chillgard 5000 Remote Display, hereafter referred to as “the device”, is an information module
which can communicate with the Chillgard 5000 Refrigerant Monitor and the Chillgard 5000 Ammonia
Monitor (hereafter referred to as the “Chillgard 5000”). The device can be installed remotely from the
main instruments, thus enabling remote visual and audio indication, alarm silence and latched alarm
reset.
The device shows the same readings and alarm messages of the Chillgard 5000 and can therefore
be used to report the gas readings of the monitored area outside of it. Best practice is to install the
device outside the machinery room next to the entry door.
In case of an alarm, it is possible to acknowledge the audible alarm of the device, the Chillgard 5000
will remain in alarm. Refer to the Chillgard 5000 user instruction (P/N 10178535) to read more detail
on alarm response.
The device will be shipped without a strobe, but offers the option to have a strobe installed afterwards.
See accessories section of this manual.
Fig. 1 Mounting location

7
Description
Chillgard 5000 Remote Display
US
3.1 Identifying Your Unit
Fig. 2 Front of device
NOTE: Strobe not within scope of delivery (can be mounted later).
Fig. 3 Back of device
Fig. 4 Right side of device
1 7″ resistive touchscreen user interface
2 Power indicator
1 Mounting locations (4″ x 6″ / 101.6 mm x 152.4 mm)
1 1/2″ conduit entry
2 Approval and serial number label
1
2
4“
(101.6 mm)
6“
(152.4 mm)
1
1
1
1
1
2

8
Description
Chillgard 5000 Remote Display
US
Fig. 5 Left side of device
Fig. 6 Open device
1 1/2″ conduit entry
1 Input power
2 Optional strobe
3 CAN-IN
4 CAN-OUT
1
1
23
4

9
Description
Chillgard 5000 Remote Display
US
3.2 Connection to the Chillgard 5000
The Chillgard 5000 Remote Display acts as the slave device in the network. The Chillgard 5000
monitor initiates and controls all communications on the network.
There are two remote display outputs from the main unit. These will support two or more remote
displays via daisy chaining.
NOTE: Refer to the Chillgard 5000 Operating Manual, PN 10178535, for more information on wiring
and the connections to the Chillgard 5000 monitor.
Fig. 7 Single remote display connection
Fig. 8 Two remote displays using separate CAN bus runs
NOTE 1: If two Chillgard 5000 Remote Displays are configured using two CAN Bus connections as
shown, jumper J5 must be removed from MIO board from Chillgard 5000 Monitor. Refer to the
Chillgard 5000 Operating Manual, PN 10178535, for more information.
MSA
Chillgard 5000
Monitor
CAN Bus
Remote Display
Local 24VAC /
VDC Power
Supply
CAN IN
Earth
MSA
Chillgard 5000
Monitor
Remote Display
Local 24VAC /
VDC Power
Supply
CAN Bus
CAN IN
Earth
Remote Display
Local 24VAC /
VDC Power
Supply
CAN IN
Earth
NOTE 1

10
Description
Chillgard 5000 Remote Display
US
Fig. 9 Two remote displays using “Daisy Chain” configuration. CAN IN of the first remote display must be
connected to the Chillgard 5000
Fig. 10 Connecting four remote displays to a single Chillgard 5000 Monitor
NOTE 1: If two Chillgard 5000 remote displays are configured using two CAN Bus connections as
shown, jumper J5 must be removed from MIO board from Chillgard 5000 Monitor. Refer to the
Chillgard 5000 Operating Manual, PN 10178535, for more information.
NOTE: Before you connect the device to the Chillgard 5000, check the software revision in the About
screen of the Chillgard 5000. For all Chillgard 5000 units with software revisions older than 1.18.xxx
(1.17.xx, 1.16.xxx), call MSA Field Service for a software upgrade. The device does not operate with
older versions.
MSA
Chillgard 5000
Monitor
CAN Bus
Remote DisplayRemote Display
Local 24VAC /
VDC Power
Supply
Local 24VAC /
VDC Power
Supply
CAN IN CAN OUT CAN IN
Earth Earth
MSA
Chillgard 5000
Monitor
Remote DisplayRemote Display
Local 24VAC /
VDC Power
Supply
CAN Bus
Local 24VAC /
VDC Power
Supply
CAN IN CAN OUT CAN IN
Earth Earth
Remote DisplayRemote Display
Local 24VAC /
VDC Power
Supply
Local 24VAC /
VDC Power
Supply
CAN IN CAN OUT CAN IN
Earth Earth
Up to 1000 ft (305m)
NOTE 1
Altri manuali per Chillgard 5000
2
Indice
Altri manuali MSA Monitor

MSA
MSA Ultima X Series Manuale utente

MSA
MSA ULTIMA X-Series Manuale utente

MSA
MSA Ultima Manuale utente

MSA
MSA ULTIMA X5000 Manuale utente

MSA
MSA Ultima Manuale utente

MSA
MSA S5000 Manuale utente

MSA
MSA General Monitors IR4000S Manuale utente

MSA
MSA MV-1901F Manuale utente

MSA
MSA GASGARD 8 Manuale utente

MSA
MSA PrimaX IR Manuale utente