MTU 20V4000GX2 Manuale utente

Operating Instructions
Diesel Engine
20V4000Gx2
M015565/03E

Engine model kW/cyl. Hz Application group
20V4000G22 110.0 kW/cyl. 50 Hz 3B, continuous operation, variable load, ICXN
20V4000G22 124.5 kW/cyl. 60 Hz 3B, continuous operation, variable load, ICXN
20V4000G22 110.0 kW/cyl. 50 Hz 3C, restricted operation, ICXN
20V4000G22 124.5 kW/cyl. 60 Hz 3C, restricted operation, ICXN
20V4000G22 121.0 kW/cyl. 50 Hz 3D, emergency power, fuel stop power, IFN
20V4000G22 137.0 kW/cyl. 60 Hz 3D, emergency power, fuel stop power, IFN
20V4000G42 124.5 kW/cyl. 60 Hz 3B, continuous operation, variable load, ICXN
20V4000G42 124.5 kW/cyl. 60 Hz 3C, restricted operation, ICXN
20V4000G42 137.0 kW/cyl. 60 Hz 3D, emergency power, fuel stop power, IFN
20V4000G62 100.0 kW/cyl. 50 Hz 3A, continuous operation, unrestricted
20V4000G62 103.0 kW/cyl. 60 Hz 3A, continuous operation, unrestricted
20V4000G62 121.0 kW/cyl. 50 Hz 3B, continuous operation, variable load, ICXN
20V4000G62 137.0 kW/cyl. 60 Hz 3B, continuous operation, variable load, ICXN
20V4000G62 121.0 kW/cyl. 50 Hz 3C, restricted operation, ICXN
20V4000G62 137.0 kW/cyl. 60 Hz 3C, restricted operation, ICXN
20V4000G62 133.5 kW/cyl. 50 Hz 3D, emergency power, fuel stop power, IFN
20V4000G62 150.5 kW/cyl. 60 Hz 3D, emergency power, fuel stop power, IFN
20V4000G82 103.0 kW/cyl. 60 Hz 3A, continuous operation, unrestricted
20V4000G82 137.0 kW/cyl. 60 Hz 3B, continuous operation, variable load, ICXN
20V4000G82 137.0 kW/cyl. 60 Hz 3C, restricted operation, ICXN
20V4000G82 150.5 kW/cyl. 60 Hz 3D, emergency power, fuel stop power, IFN
Table 1: Applicability
© 2016 Copyright MTU Friedrichshafen GmbH
This publication is protected by copyright and may not be used in any way, whether in whole or in part, without the prior writ-
ten consent of MTU Friedrichshafen GmbH. This particularly applies to its reproduction, distribution, editing, translation, micro-
filming and storage or processing in electronic systems including databases and online services.
All information in this publication was the latest information available at the time of going to print. MTU Friedrichshafen GmbH
reserves the right to change, delete or supplement the information provided as and when required.

Table of Contents
1 Safety
1.1 Important provisions for all products 5
1.2 Correct use for all products 6
1.3 Personnel and organizational requirements 7
1.4 Safety regulations for startup and operation 8
1.5 Safety precautions when working on the
engine 10
1.6 Fire prevention and environmental
protection, fluids and lubricants, auxiliary
materials 13
1.7 Standards for safety notices in the text 15
2 Transport
2.1 Transportation 16
2.2 Lifting requirements 17
2.3 Crankshaft transport locking device 18
3 General Information
3.1 Engine side and cylinder designations 21
3.2 Engine overview 22
4 Technical Data
4.1 20V4000 continuous operation, unrestricted
3A, optimized fuel consumption G62,
emissions-optimized (EPA) G82 23
4.2 20V4000 continuous operation, variable 3B,
optimized fuel consumption G22/G62,
emissions-optimized (“TA-Luft”) G22/G62,
emissions-optimized (EPA) G42/G82 27
4.3 20V4000 continuous operation, restricted
3C, optimized fuel consumption G22/G62,
emissions-optimized (“TA-Luft”) G22/G62 32
4.4 20V4000 standby power 3D, optimized fuel
consumption G22/G62, emissions-optimized
(EPA) G42/G82 36
4.5 Final compression pressure 40
4.6 Firing order 41
4.7 Main engine dimensions 42
5 Operation
5.1 Putting the engine into operation after
extended out-of-service periods (>3 months) 43
5.2 Putting the engine into operation after
scheduled out-of-service-period 44
5.3 Engine – Starting in manual mode (test run) 45
5.4 Starting the engine in emergency situations
(override mode) 46
5.5 Operational monitoring 47
5.6 Engine – Stopping in manual mode (test
run) 48
5.7 Engine – Emergency stop 49
5.8 After stopping the engine – Putting the
engine out of operation 50
5.9 Plant – Cleaning 51
6 Maintenance
6.1 Maintenance task reference table [QL1] 52
7 Troubleshooting
7.1 Troubleshooting 53
7.2 Fault messages on engine governor 56
8 Task Description
8.1 Engine 67
8.1.1 Engine – Barring manually 67
8.1.2 Engine – Cranking on starting system 69
8.1.3 Engine – Test run 70
8.2 Cylinder Liner 71
8.2.1 Cylinder liner – Endoscopic examination 71
8.2.2 Instructions and comments on endoscopic and
visual examination of cylinder liners 73
8.3 Crankcase Breather 75
8.3.1 Crankcase breather – Oil separator element
replacement 75
8.4 Valve Drive 77
8.4.1 Cylinder head cover – Removal and
installation 77
8.4.2 Valve gear – Lubrication 78
8.4.3 Valve clearance – Check and adjustment 79
8.5 Injection Pump / HP Pump 84
8.5.1 HP fuel pump – Relief bore check 84
8.6 Injector 85
8.6.1 Injector – Replacement 85
8.6.2 Injector – Removal and installation 86
8.7 Fuel System 91
8.7.1 Fuel system – Venting 91
8.8 Fuel Filter 92
8.8.1 Fuel filter – Replacement 92
8.8.2 Fuel prefilter – Cleaning 93
8.8.3 Fuel prefilter – Differential pressure gage
check and adjustment of gage 94
M015565/03E 2016-02 | Table of Contents | 3
DCL-ID: 0000034750 - 001

8.8.4 Fuel prefilter – Draining 95
8.8.5 Fuel prefilter – Flushing 96
8.8.6 Fuel prefilter – Filter element replacement 98
8.9 Charge-Air Cooling 100
8.9.1 Intercooler – Check water drain for coolant
leakage and absence of restrictions 100
8.10 Air Filter 101
8.10.1 Air filter ‒ Replacement 101
8.10.2 Air filter – Removal and installation 102
8.11 Air Intake 103
8.11.1 Service indicator – Signal ring position check 103
8.12 Starting Equipment 104
8.12.1 Air starter – Manual operation 104
8.13 Lube Oil System 105
8.13.1 Engine oil – Level check 105
8.13.2 Engine oil – Change 106
8.14 Oil Filtration / Cooling 108
8.14.1 Engine oil filter – Replacement 108
8.14.2 Centrifugal oil filter – Cleaning and filter-
sleeve replacement 109
8.15 Coolant Circuit, General, High-Temperature
Circuit 111
8.15.1 Engine coolant – Level check 111
8.15.2 Engine coolant – Change 112
8.15.3 Engine coolant – Draining 113
8.15.4 Engine coolant – Filling 114
8.15.5 Engine coolant pump – Relief bore check 116
8.16 Low-Temperature Circuit 117
8.16.1 Charge-air coolant – Level check 117
8.16.2 Charge-air coolant – Change 118
8.16.3 Charge-air coolant draining 119
8.16.4 Charge-air coolant – Filling 120
8.16.5 Charge-air coolant pump – Relief bore check 122
8.17 Belt Drive 123
8.17.1 Drive belt – Condition check 123
8.18 Battery-Charging Generator 124
8.18.1 Battery-charging generator drive – Drive belt
tension adjustment 124
8.18.2 Battery-charging generator drive – Drive belt
condition check 125
8.18.3 Battery-charging generator drive – Drive belt
replacement 126
8.19 Engine Mounting / Support 127
8.19.1 Engine mounting – Resilient mount check 127
8.20 Cabling 128
8.20.1 Engine cabling – Check 128
8.21 Accessories for (Electronic) Engine
Governor / Control System 129
8.21.1 Engine Control Unit and connectors – Cleaning 129
8.21.2 Engine Control Unit – Plug connection check 130
9 Appendix A
9.1 Abbreviations 131
9.2 MTU Contact/Service Partners 134
10 Appendix B
10.1 Special Tools 135
10.2 Index 141
4 | Table of Contents | M015565/03E 2016-02
DCL-ID: 0000034750 - 001

1 Safety
1.1 Important provisions for all products
Nameplate
The product is identified by nameplate, model designation or serial number and must match with the infor-
mation on the title page of this manual.
Nameplate, model designation or serial number can be found on the product.
All EU-certified engines delivered by MTU come with a second nameplate. When operating the machine in the
EU: The second nameplate must be affixed in a prominent position as described in the accompanying specifi-
cations.
General information
This product may pose a risk of injury or damage in the following cases:
• Incorrect use
• Operation, maintenance and repair by unqualified personnel
• Modifications or conversions
• Noncompliance with the safety instructions and warning notices
Emission regulations and emission labels
Responsibility for compliance with emission regulations
Modification or removal of any mechanical/electronic components or the installation of additional compo-
nents including the execution of calibration processes that might affect the emission characteristics of the
product are prohibited by emission regulations. Emission control units/systems may only be maintained, ex-
changed or repaired if the components used for this purpose are approved by the manufacturer.
Noncompliance with these regulations will invalidate the design type approval issued by the emissions regu-
lation authorities. The manufacturer does not accept any liability for violations of the emission regulations.
The maintenance schedules of the manufacturer must be observed over the entire life cycle of the product.
Replacing components with emission labels
On all MTU engines fitted with emission labels, these labels must remain on the engine throughout its opera-
tional life.
Engines used exclusively in land-based, military applications other than by US government agencies are ex-
cepted from this proviso.
Please note the following when replacing components with emission labels:
• The relevant emission labels must be affixed to the spare part.
• Do not transfer the emission labels from the replaced part to the spare part.
• Remove the emission labels from the replaced part and destroy them.
M015565/03E 2016-02 | Safety | 5
TIM-ID: 0000040530 - 008

1.2 Correct use for all products
Correct use
The product is intended for use in accordance with its contractually-defined purpose as described in the rele-
vant technical documents only.
Intended use entails operation:
• Within the permissible operating parameters in accordance with the (→ Technical data)
• With fluids and lubricants approved by the manufacturer in accordance with the (→ Fluids and Lubricants
Specifications of the manufacturer)
• With preservation approved by the manufacturer in accordance with the (→ Preservation and Represerva-
tion Specifications of the manufacturer)
• With spare parts approved by the manufacturer in accordance with the (→ Spare Parts Catalog/MTU con-
tact/Service partner)
• In the original as-delivered configuration or in a configuration approved by the manufacturer in writing (in-
cluding engine control/parameters)
• In compliance with all safety regulations and in adherence with all warning notices in this manual
• In compliance with the maintenance work and intervals specified in the (→ Maintenance Schedule)
throughout the useful life of the product
• In compliance with the maintenance and repair instructions contained in this manual, in particular with
regard to the specified tightening torques
• With the exclusive use of technical personnel trained in commissioning, operation, maintenance and re-
pair
• By contracting only workshops authorized by the manufacturer to carry out repair and overhaul
The product shall not be operated in explosive atmospheres unless the necessary approval has been grant-
ed.
Any other use, particularly misuse, is considered as being contrary to the intended purpose. Such improper
use increases the risk of injury and damage when working with the product. The manufacturer shall not be
held liable for any damage resulting from improper, non-intended use.
The specifications of the manufacturer will be amended or supplemented as necessary. Prior to operation,
make sure that the latest version is used. The latest version can be found on the websites:
• For drive systems: http://www.mtu-online.com
• For power generation: http://www.mtuonsiteenergy.com
Modifications or conversions
Unauthorized changes to the product represent a contravention of its intended use and compromise safety.
Changes or modifications shall only be considered to comply with the intended use when expressly author-
ized by the manufacturer. The manufacturer shall not be held liable for any damage resulting from unauthor-
ized changes or modifications.
6 | Safety | M015565/03E 2016-02
TIM-ID: 0000065671 - 001

1.3 Personnel and organizational requirements
Organizational measures of the user/manufacturer
This manual must be issued to all personnel involved in operation, maintenance, repair, assembly, installa-
tion, or transportation.
Keep this manual handy in the vicinity of the product such that it is accessible to operating, maintenance,
repair, assembly, installation, and transport personnel at all times.
Personnel must receive instruction on product handling and maintenance based on this manual with a spe-
cial emphasis on safety requirements and warnings.
This is important in the case of personnel who only occasionally perform work on or around the product.
These personnel must be instructed repeatedly.
Personnel requirements
All work on the product shall be carried out by trained and qualified personnel only:
• Training at the Training Center of the manufacturer
• Technical personnel from the areas mechanical engineering, plant construction, and electrical engineering
The operator must define the responsibilities of the personnel involved in operation, maintenance, repair, as-
sembly, installation, and transport in writing.
Personnel shall not report for duty under the influence of alcohol, drugs or strong medication.
Clothing and personal protective equipment
Always wear appropriate personal protective equipment, e.g. safety shoes, ear protectors, protective gloves,
goggles, breathing mask. Follow the instructions concerning personal protective equipment in the descrip-
tions of the individual activities.
M015565/03E 2016-02 | Safety | 7
TIM-ID: 0000040531 - 008

1.4 Safety regulations for startup and operation
Safety regulations for startup
Install the product correctly and carry out acceptance in accordance with the manufacturer's specifications
before putting the product into service. All necessary approvals must be granted by the relevant authorities
and all requirements for initial startup must be fulfilled.
Whenever the product is subsequently taken into operation ensure that:
• All personnel is clear of the danger zone surrounding moving parts of the machine.
Electrically-actuated linkages may be set in motion when the Engine Control Unit (governor) is switched
on.
• All maintenance and repair work has been completed.
• All loose parts have been removed from rotating machine components.
• All safety equipment is in place.
• No persons wearing pacemakers or any other technical body aids are present.
• The service room is adequately ventilated.
• In the first few hours of operation, the product emits gases as a result of smoldering e.g. lacquers or oil.
These gases may be hazardous to health. Always wear respiratory protection in the operating room during
this period.
• The exhaust system is leak-tight and that the gases are vented to atmosphere.
• Protect battery terminals, generator terminals or cables against accidental contact.
• Check that all connections have been correctly allocated (e.g. +/- polarity, direction).
Immediately after putting the product into operation, make sure that all control and display instruments as
well as the signaling and alarm systems work properly.
Smoking is prohibited in the area of the product.
Safety regulations during operation
The operator must be familiar with the control and display elements.
The operator must be familiar with the consequences of any operations performed.
During operation, the display instruments and monitoring units must be permanently observed with regard to
present operating status, violation of limit values and warning or alarm messages.
Malfunctions and emergency stop
Practice emergency procedures, especially emergency stopping, at regular intervals.
The following steps must be taken if a malfunction of the system is detected or reported by the system:
• Inform supervisor(s) in charge.
• Analyze the message.
• Respond by taking any necessary emergency action, e.g. emergency stop.
Operation
Do not remain in the operating room when the product is running for any longer than absolutely necessary.
Keep a safe distance away from the product if possible. Do not touch the product unless expressly instructed
to do so following a written procedure.
Do not inhale the exhaust gases of the product.
The following requirements must be fulfilled before the product is started:
• Wear ear protection.
• Mop up any leaked or spilled fluids and lubricants immediately or soak up with a suitable binder agent.
Operation of electrical equipment
Parts of the electrical equipment are live, i.e. under voltage/high tension, during operation.
8 | Safety | M015565/03E 2016-02
TIM-ID: 0000040533 - 012

Follow the applicable warning instructions pertaining to such devices.
M015565/03E 2016-02 | Safety | 9
TIM-ID: 0000040533 - 012

1.5 Safety precautions when working on the engine
Safety regulations prior to maintenance and repair work
Have maintenance or repair work carried out by qualified and authorized personnel only.
Allow the product to cool down to less than 50 °C (risk of explosion for oil vapors, fluids and lubricants, risk
of burning).
Relieve pressure in fluid and lubricant systems and compressed-air lines which are to be opened. Use suita-
ble collecting vessels of adequate capacity to catch fluids and lubricants.
When changing the oil or working on the fuel system, ensure that the service room is adequately ventilated.
Never carry out maintenance and repair work with the product in operation, unless:
• It is expressly permitted to do so following a written procedure.
• The product is running in the low load range and only for as long as absolutely necessary.
Lock-out the product to preclude undesired starting, e.g.
• Start interlock
• Key switch
• With hydraulic starting system: shut off supply line.
Attach “Do not operate” sign in the operating area or to control equipment.
Disconnect the battery cables or actuate the battery isolating switch, if fitted. Lock out circuit breakers.
Close the main valve on the compressed-air system and vent the compressed-air line when pneumatic start-
ers are fitted.
Disconnect the control equipment from the product.
Use the recommended special tools or suitable equivalents when instructed to do so.
Elastomer components (e.g. engine mounts, damping elements, couplings and V-belts) must not be painted.
They may only be installed after painting the engine or must be covered before painting work is carried out.
The following applies to starters with copper-beryllium alloy pinions:
• Wear a respirator mask (filter class P3). Do not blow out the interior of the flywheel housing or the starter
with compressed air. Clean the flywheel housing inside with a class H dust extraction device.
• Observe the safety data sheet.
Safety regulations during maintenance and repair work
Take special care when removing ventilation or plug screws from the product.
Release residual pressure before removing or replacing a component in the supply line. To depressurize pres-
surized lines, shut off the lines first, then release the residual pressure.
Use only proper and calibrated tools. Observe the specified tightening torques during assembly or disassem-
bly.
Carry out work only on assemblies or plants which are properly secured.
Make sure components or assemblies are placed on stable surfaces. Adopt suitable measures to avoid that
components/tools fall down. Use the specified lifting equipment for all components.
Never use the product as a climbing aid.
When working high on the equipment, always use suitable ladders and work platforms. Never work on en-
gines or components that are held in place by lifting equipment.
Keep fuel injection lines and connections clean.
Carry out appropriate cleaning procedures to clean and inspect components requiring special cleanness (e.g.
components carrying oil, fuel, or air).
Always seal connections with caps or covers if a line is removed or opened.
Fit new seals when re-installing lines.
10 | Safety | M015565/03E 2016-02
TIM-ID: 0000040535 - 012
Indice
Altri manuali MTU Motore

MTU
MTU 8 V 2000 M51A Manuale utente

MTU
MTU 20V4000L63 Manuale utente

MTU
MTU 12V4000L62FB Manuale utente

MTU
MTU 12V4000Gx5S Series Manuale utente

MTU
MTU 12 V 4000 S83L Manuale utente

MTU
MTU 8V1600 G10F Manuale utente

MTU
MTU 12 V 2000 G25 Manuale utente

MTU
MTU 12 V 2000 M94 Manuale utente

MTU
MTU 12V2000M94 Manuale utente

MTU
MTU 12 V 4000 G23 Guida

MTU
MTU 12 V 4000 M63 Manuale utente

MTU
MTU 12 V 4000 L63 Manuale utente

MTU
MTU 12V4000G34F Manuale utente

MTU
MTU 20V4000M73 series Manuale utente

MTU
MTU 6R1600M20x Manuale utente

MTU
MTU 8V4000M*3 series Manuale utente

MTU
MTU 12 V 4000 C20 Manuale utente

MTU
MTU 8V4000Mx4 Manuale utente

MTU
MTU 8 V 4000 M40A Manuale utente

MTU
MTU 12V4000L32FB Manuale utente