National Instruments PXIe-5785 Manuale utente

GETTING STARTED GUIDE
PXIe-5785
12-Bit, 6.4 GS/s, 2-Channel PXI FlexRIO IF Transceiver
This document explains how to install, configure, test, and use the PXIe-5785. You can
program the PXIe-5785 with the following software options.
• FlexRIO driver software
• NI LabVIEW Instrument Design Libraries for FlexRIO (instrument design libraries)
Note Before you begin, install and configure your chassis and controller.
Note Adapter modules are not installable or interchangeable on PXIe-5785
devices.
Contents
FlexRIO Documentation and Resources...................................................................................2
Verifying the System Requirements..........................................................................................2
Unpacking the Kit..................................................................................................................... 3
PXIe-5785 Kit Contents............................................................................................................3
Preparing the Environment....................................................................................................... 4
Installing the Software and Driver............................................................................................ 4
Installing the PXIe-5785........................................................................................................... 5
PXIe-5785 Front Panel..............................................................................................................6
Configuring the PXIe-5785 in MAX........................................................................................ 8
FlexRIO Examples....................................................................................................................9
Accessing FlexRIO Examples.......................................................................................... 9
Block Diagram.......................................................................................................................... 9
Component-Level Intellectual Property (CLIP)......................................................................11
Making a Measurement...........................................................................................................12
Making a Measurement with LabVIEW.........................................................................12
Troubleshooting...................................................................................................................... 12
What Should I Do if the PXIe-5785 Doesn't Appear in MAX?......................................12
What Should I Do if the PXIe-5785 Fails the Self-Test?................................................12
Where to Go Next................................................................................................................... 13
Worldwide Support and Services............................................................................................ 13

FlexRIO Documentation and Resources
Table 1. FlexRIO Documentation and Resources
Document/Resource Location Description
PXIe-5785 Getting
Started Guide (this
document)
Available at ni.com/
manuals.
Contains installation instructions and
basic programming instructions for
your PXIe-5785.
PXIe-5785
Specifications
Available at ni.com/
manuals.
Contains specifications for your
PXIe-5785.
PXIe-5785 Safety,
Environmental, and
Regulatory Information
Available at ni.com/
manuals.
Contains important safety,
environmental, and regulatory
information for your PXIe-5785.
LabVIEW FPGA Module
Help
Embedded in LabVIEW
Help and at ni.com/
manuals.
Contains information about the basic
functionality of the LabVIEW FPGA
Module.
FlexRIO Help Available at ni.com/
manuals.
Contains information about the FPGA
module front panel connectors and
I/O, programming instructions, and
I/O component-level IP (CLIP).
LabVIEW Examples Available in NI Example
Finder. In LabVIEW,
click Help»Find
Examples»Hardware
Input and Output»
FlexRIO.
Contains examples of how to run
FPGA VIs and Host VIs on your
device.
IPNet Located at ni.com/ipnet. Contains LabVIEW FPGA functions
and intellectual property to share.
FlexRIO product page Located at ni.com/flexrio. Contains product information and
data sheets for FlexRIO devices.
Verifying the System Requirements
To use the PXIe-5785, your system must meet certain requirements. For more information
about minimum system requirements, recommended system, and supported application
development environments (ADEs), refer to the readme, which is available on the software
media or online at ni.com/updates.
2| ni.com | PXIe-5785 Getting Started Guide

Unpacking the Kit
Notice To prevent electrostatic discharge (ESD) from damaging the device, ground
yourself using a grounding strap or by holding a grounded object, such as your
computer chassis.
1. Touch the antistatic package to a metal part of the computer chassis.
2. Remove the device from the package and inspect the device for loose components or any
other sign of damage.
Notice Never touch the exposed pins of connectors.
Note Do not install a device if it appears damaged in any way.
3. Unpack any other items and documentation from the kit.
Store the device in the antistatic package when the device is not in use.
PXIe-5785 Kit Contents
The following items are included in the device kit:
• PXIe-5785
• FlexRIO driver software media
• Documentation:
–Maintain Forced-Air Cooling Note to Users
–PXIe-5785 Getting Started Guide (this document)
–PXIe-5785 Safety, Environmental, and Regulatory Information
PXIe-5785 Getting Started Guide | © National Instruments | 3

Preparing the Environment
Ensure the environment in which you are using the PXIe-5785 meets the following
specifications.
Operating environment
Ambient temperature range 0 °C to 55 °C1 (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 low temperature
limit and MIL-PRF-28800F Class 2 high
temperature limit.)
Relative humidity range 10% to 90%, noncondensing (Tested in
accordance with IEC 60068-2-56.)
Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient
temperature)
Pollution Degree 2
Indoor use only.
Note For complete specifications, refer to the specifications document for your
device at ni.com/manuals.
Installing the Software and Driver
Before installing your hardware, you must install the application software and instrument
driver. Visit NI FlexRIO Driver Supported Versions for FlexRIO Adapters and Modules to
determine which minimum software versions you need for your device. Install the software in
the following order:
1. Install LabVIEW.
Refer to the LabVIEW Installation Guide for installation instructions for LabVIEW and
system requirements for the LabVIEW software. Refer to the LabVIEW Upgrade Notes
for additional information about upgrading to the most recent version of LabVIEW for
Windows. Documentation for LabVIEW is available at ni.com/manuals.
2. Install the LabVIEW FPGA Module.
Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installation
instructions and information about getting started with the LabVIEW FPGA Module.
Documentation for the LabVIEW FPGA Module is available at ni.com/manuals.
3. (Optional) Install the LabVIEW Real-Time Module.
1The PXIe-5785 requires a chassis with slot cooling capacity ≥58 W. Not all chassis with slot
cooling capacity ≥58 W can achieve this ambient temperature range. Refer to the PXI Chassis
Manual for specifications to determine the ambient temperature ranges your chassis can achieve.
4| ni.com | PXIe-5785 Getting Started Guide

Refer to the LabVIEW Real-Time Module Release and Upgrade Notes for system
requirements, installation instructions, and additional information about using the
LabVIEW Real-Time Module.
4. Install FlexRIO.
Refer to the FlexRIO Readme for system requirements and installation instructions for
FlexRIO. Documentation for FlexRIO is available at ni.com/manuals.
Installing the PXIe-5785
Notice To prevent damage to the PXIe-5785 caused by ESD or contamination,
handle the module using the edges or the metal bracket.
1. Ensure the AC power source is connected to the chassis before installing the module.
The AC power cord grounds the chassis and protects it from electrical damage while you
install the module.
2. Power off the chassis.
3. Inspect the slot pins on the chassis backplane for any bends or damage prior to
installation. Do not install a module if the backplane is damaged.
4. Remove the black plastic covers from all the captive screws on the module front panel.
5. Identify a supported slot in the chassis. The following figure shows the symbols that
indicate the slot types.
Figure 1. Chassis Compatibility Symbols
NI PXIe-1062Q
12 3 45
1. PXI Express System Controller Slot
2. PXI Peripheral Slot
3. PXI Express Hybrid Peripheral Slot
4. PXI Express System Timing Slot
5. PXI Express Peripheral Slot
PXIe-5785 modules can be placed in PXI Express peripheral slots, PXI Express hybrid
peripheral slots, or PXI Express system timing slots.
6. Touch any metal part of the chassis to discharge static electricity.
7. Ensure that the ejector handle is in the downward (unlatched) position.
8. Place the module edges into the module guides at the top and bottom of the chassis. Slide
the module into the slot until it is fully inserted.
PXIe-5785 Getting Started Guide | © National Instruments | 5

Figure 2. Module Installation
2
3
NI PXIe-1075
1
1. Chassis
2. Hardware Module
3. Ejector Handle in Downward (Unlatched) Position
9. Latch the module in place by pulling up on the ejector handle.
10. Secure the module front panel to the chassis using the front-panel mounting screws.
Note Tightening the top and bottom mounting screws increases mechanical
stability and also electrically connects the front panel to the chassis, which can
improve the signal quality and electromagnetic performance.
11. Cover all empty slots using EMC filler panels or fill using slot blockers to maximize
cooling air flow, depending on your application.
12. Power on the chassis.
PXIe-5785 Front Panel
The following figure shows the PXIe-5785 front panel.
6| ni.com | PXIe-5785 Getting Started Guide

Figure 3. PXIe-5785 Front Panel
12-Bit, 6.4 GS/s
DIO
REF/
CLK IN
AI 0
AI 1
AO 0
AO 1
PXIe-5785
FlexRIO IF Transceiver
4 Vpp
MAX
4 Vpp
MAX
The following table describes the signal connections for the PXIe-5785.
Connector Description Function
DIO Molex Nano-Pitch DIO
connector
Multi-signal DIO connector that provides
access to FPGA multi-gigabit transceivers
(MGTs) and general-purpose LVCMOS
signals.
AI 0:1 Standard SMA female
connector
Analog input connection.
PXIe-5785 Getting Started Guide | © National Instruments | 7

Connector Description Function
AO 0:1 Standard SMA female
connector
Analog output connection.
REF/CLK IN Standard SMA female
connector
Input for an external Reference Clock or
Sample Clock.
The following table lists the available pins on the DIO connector.
Signal Type Direction
MGT Tx± <3..0> 2Xilinx UltraScale GTH Output
MGT Rx± <3..0>2Xilinx UltraScale GTH Input
DIO <7..0> Single-ended Bidirectional
5.0 V DC Output
GND Ground —
Notice The maximum input signal levels are valid only when the module is
powered on. To avoid permanent damage to the PXIe-5785, do not apply a signal to
the device when the module is powered down.
Notice Connections that exceed any of the maximum ratings of any connector on
the PXIe-5785 can damage the device and the chassis. NI is not liable for any
damage resulting from such connections.
Configuring the PXIe-5785 in MAX
Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX
informs other programs about which NI hardware products are in the system and how they are
configured. MAX is automatically installed with FlexRIO.
1. Launch MAX.
2. In the configuration tree, expand Devices and Interfaces to see the list of installed NI
hardware.
Installed modules appear under the name of their associated chassis.
3. Expand your Chassis tree item.
2MGTs are available only on devices with KU040 and KU060 FPGAs.
8| ni.com | PXIe-5785 Getting Started Guide

MAX lists all modules installed in the chassis. Your default names may vary.
Note If you do not see your module listed, press <F5> to refresh the list of
installed modules. If the module is still not listed, power off the system, ensure
the module is correctly installed, and restart.
4. Record the identifier MAX assigns to the hardware. Use this identifier when
programming the PXIe-5785.
5. Self-test the hardware by selecting the item in the configuration tree and clicking Self-
Test in the MAX toolbar.
The MAX self-test performs a basic verification of hardware resources.
FlexRIO Examples
FlexRIO includes several example applications for LabVIEW. These examples serve as
interactive tools, programming models, and as building blocks in your own applications.
Accessing FlexRIO Examples
FlexRIO examples are available in LabVIEW's NI Example Finder. Complete the following
steps to access the examples by task.
1. In LabVIEW, click Help»Find Examples.
2. In the NI Example Finder window that appears, click Hardware Input and Output»
FlexRIO.
The examples are sorted by task. Click on an example and refer to the Information
window for a description of the example. Refer the Requirements window for a list of
hardware devices that can run the example.
You can also click the Search tab to search all installed examples by keyword. For
example, search for FlexRIO to locate all FlexRIO examples.
Examples also are available online that demonstrate FlexRIO basics, such as using DRAM,
acquiring data from adapter modules, and performing high throughput streaming. Refer to
ni.com/examples for these examples and for more information.
Block Diagram
The following figure shows a block diagram of the carrier portion of the PXIe-5785 (KU035
FPGA option).
PXIe-5785 Getting Started Guide | © National Instruments | 9

Figure 4. Carrier Block Diagram (KU035)
DIO Connector
(Front Panel)
Adapter Module
Connector
+5 V
+1.8 V
+12 V
GPIO
Configuration, GPIO
MGTs
Reference Clock
Power Supplies
Flash
FPGA
PXIe Connectors
PXI Triggers
Clk 100
DStarB, DStarC
Gen3 x8 PCIe
+12 V, +3.3 V
+12 V
Clk 10
Module Clocking
Synchronization
The following figure shows a block diagram of the carrier portion of the PXIe-5785 (KU040
and KU060 FPGA options).
Figure 5. Carrier Block Diagram (KU040 and KU060)
DIO Connector
(Front Panel)
Adapter Module
Connector
+5 V
+1.8 V
+12 V
GPIO
Configuration, GPIO
MGTs
Reference Clock
Power Supplies
Flash
FPGA
PXIe Connectors
PXI Triggers
Clk 100
DStarB, DStarC
Gen3 x8 PCIe
+12 V, +3.3 V
+12 V
Clk 10
Module Clocking
Synchronization
MGTs
DRAM Bank 0
(2 GB)
DRAM Bank 1
(2 GB)
The following figure shows a block diagram of the I/O portion of the PXIe-5785.
10 | ni.com | PXIe-5785 Getting Started Guide
Indice
Altri manuali National Instruments Ricetrasmettitore

National Instruments
National Instruments NI PXIe-5644R Manuale utente

National Instruments
National Instruments PXIe-5842 Manuale utente

National Instruments
National Instruments NI PXIe-5645R Manuale utente

National Instruments
National Instruments PCIe-5785 Manuale utente

National Instruments
National Instruments USRP-2950 Manuale utente

National Instruments
National Instruments USRP-2900 Manuale utente

National Instruments
National Instruments USRP-2920 Manuale utente

National Instruments
National Instruments PXIe-3610 Manuale utente

National Instruments
National Instruments PXIe-5646R Manuale utente

National Instruments
National Instruments PXIe-5830 Manuale utente