Nera Saturn B Manuale utente

Standard
• Charge Tone
• Traffic Log
• Access Code
Optional
• Precharge
• Restricted LES
• Restricted Dialing
• Cryptophone STUIII/STUIIB
• Credit Card Phone
Saturn B/M Enhanced Functions
Operator’s Manual


Saturn B/M Enhanced Functions – Operator’s Manual
Chapter 1. Introduction
About Enhanced Functions ...................... 1.1
Protection ................................................. 1.2
Renter/Owner Level ................................. 1.3
Password ................................................. 1.5
Chapter 2. Standard
Charge Tone ............................................ 2.1
Traffic Logging ......................................... 2.3
Access Code .......................................... 2.13
Chapter 3. Optional
Precharge ................................................. 3.1
Restricted LES ......................................... 3.3
Restricted Dialing ..................................... 3.4
Cryptophone STU III and STU IIB ............ 3.5
Credit Card Phone ................................... 3.6
APPENDIX –
Overview of Functions
1. Introduction
2. Standard
3. Optional
Appendix
5. Appendices
Doc. No. QLZB911016 Rev. B Copytema 5156 02/98
Nera SatCom AS reserves the right to change the design
and specifications of the equipment without notice.


Saturn B/M Enhanced Functions – Chapter 1. Introduction
Contents
About Enhanced Functions ........................................................ 1.1
Protection ................................................................................... 1.2
Renter/Owner Level .................................................................... 1.3
Password .................................................................................... 1.5
Chapter 1. Introduction
Nera SatCom AS reserves the right to change the design
and specifications of the equipment without notice.


Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.1
About Enhanced Functions
About Enhanced Functions
Standard Enhanced Functions
The following Enhanced Functions are available as standard for
Saturn B and Saturn M terminals:
•Charge tone, which sends a tone on selected telephone ports
when charging starts.
•Traffic log, which logs traffic data from selected telephone ports
and provides detailed printout.
•Access code, which allocates a personal 1-8 digit code to up to
100 authorized users. The code opens the system for one call.
Optional Enhanced Functions
The Enhanced Functions below are available as options:
•Precharge, which allows preprogramming the Saturn M or B
terminal with a maximum total call duration. The maximum call
duration can be extended by the owner.
•Restricted LES, which allows the owner to lock the terminal to
one specific LES per Ocean Region.
•
Restricted Dialing, which allows calls to preset short numbers only.
•STU III and STU IIB, which prepares selected port(s) for use with
encrypted telephone.
•Credit Card Phone, which prepares selected port(s) for use with
credit card telephone.
Activation of these functions requires individual opening keys pro-
vided when purchasing the functions.
Optional Data and Telex Functions
Data link and telex functions are also available as options:
•
High Speed Data, HSD, which offers 56/64 kbps full duplex or sim-
plex link with terrestrial ISDN networks (Saturn B only).
•
Asynchronous Data, ASD, which offers data transmission at
2.4 kbps (Saturn M) or 9.6 kbps (Saturn B) via its built-in modem.
•
Telex, simplex and duplex (Saturn B only).
See separate manuals.
Installation
Enhanced Functions are activated using the "Enhanced Setup"
function no. 89.
Only Enhanced Functions that have been activated are listed when
searching through the main menu "Enhanced Functions" no.8.
Functions that are not yet activated appear as "PASSIVE" when
opening the "Enhanced Setup" function no.89.
See appendix for an overview of Saturn B/M functions.

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.2
Protection
ON
OWN.
RENT. OPER.
SETUP OPEration
UPDATE OPEration VIEW OPEration
Protection
General
Two password protected user levels are provided in addition to USER
and OPERATOR level:
•RENTER, and
•OWNER
A common default password (1 2 3 4 5 6) facilitates the activation of
Enhanced Functions for new users (see "Password").
Warning! An individual OWNER password must be entered to protect
the equipment against unauthorized use. The password must be
stored in a safe place.
For safety purposes, protect all telephone ports, see "Access Code".
Up to three different operation rights can be assigned with selecta-
ble access level to each Enhanced Function:
• SETUP OPERATION – allows such as selection of ports.
Default access level: OWNER.
• UPDATE OPERATION – such as entering/deletion of data.
Default access level: OWNER.
• VIEW OPERATION – such as display readout and printout.
Default access level: OPERATOR
When activating a function, the access level required to operate each
right can be seen in the display when pressing MORE/HELP.
See example below.
Setup operations can be accessed from RENTER or OWNER level
only.

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.3
General
The Saturn M/B terminals provide the following access levels in
addition to USER (1) level and OPERATOR (2) level:
•RENTER (3), and
•OWNER (4)
The RENTER and OWNER levels are protected by passwords.
The default password for both levels is 1 2 3 4 5 6.
Password protection can be used to restrict operative functions to
different parameter levels, e.g.:
• level 4 (OWNER) allowed to change setup.
• level 3 (RENTER) allowed to read data.
• level 2 (OPERATOR) given no access to reading or setup.
• level 1 (USER) has standard minimum operational functions.
These restrictions can be applied according to function, e.g.:
The RENTER level can be allowed to configure the traffic log, but
restricted to reading only in the access code function.
An individual password may be assigned to each level using the "SET
PASSWORD" function no.13, see "Password".
To Set Access Level:
1Select SET USER
LEVEL function (12):
2Display the current level:
3Key in operator level ref. number,
e.g. 3 (RENTER):
3=RENTER, 4=OWNER
4Key in the current password for this
level (the default password
is 1 2 3 4 5 6):
5
The terminal is now set to RENTER LEVEL:
This level is active until a new level is set or the
terminal is switched off. Therefore, set the level
back to USER when finished with your operations.
and revert to IDLE:
Renter/Owner Level
ON
SET USER
LEVEL
12
ENTER
FUNC
ON
LEVEL:
USER
1
ABC
ENTER
2
DEF
PLAY
ON
LEVEL:
?
3
GHI
ENTER
ON
LEVEL:
RENTER
ON
PASSWORD
?
ENTER
ESC
3x
2
DEF
PLAY
1
ABC
6
PQR
4
JKL
5
MNO
3
GHI
Renter/Owner Level

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.4
Renter/Owner Level Cont’d
Optional Functions
When purchasing one or a set of Optional Enhanced Functions, an
"Opening Key" will be provided that cause the function(s) to be in-
stalled. Proceed as under "To Set Access Level":
1Select SET USER LEVEL function (12)
2Display current level
3At the "LEVEL" prompt, key in 5 9 6.
4At the "PASSWORD" prompt, key in the "Opening Key" provided
by the agent.
The function(s) are now installed.
5Activate the function using the ENHANCED SETUP function (89)
described later in this manual.
Renter/Owner Level Cont’d
Altri manuali per Saturn B
2
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Nera Terminale touch