Ness 101-091 Manuale di istruzioni

Innovative Electronic Solutions
INSTALLATION & USER MANUAL
101-091 / 101-091B
Ultraprox Bluetooth Keypad/Reader
Rev 1.0

1
CONTENTS
INTRODUCTION…………………..................................................................................…………………1
INSTALLATION…………………………..................................................................................……………3
STANDALONEMODE……....................................................................................………………………5
CONTROLLERMODE……….................................................................................………………………11
WIEGANDREADERMODE……....................................................................................………………13
ADVANCEDAPPLICATION…………..............................................................................……………..15

2
INTRODUCTION
The XK Series device is a single door multifunction standalone access controller or a Wiegand output reader. It uses
Atmel MCU assuring stable performance. The operation is very user-friendly, and low-power circuit makes it long
service life.
The XK Series device supports 1,000 users (998 common users + 2 panic users), all user data can be transferred from
one to another. It supports multi access modes in either card access, PIN access, Card + PIN access, or multi cards/PINs
access. It has extra features including block enrollment, interlocked, Wiegand 26~37 bits interface, etc that are
highlighter below.
Features
Bluetooth Module, to connect mobile App for opening door
Fashion design, all-metal key button
Metal Case, Anti-vandal
Waterproof, conforms to IP66
One relay, 1,000 users (998 common users + 2 panic users)
PIN length: 4~6 digits
Card type:
EM version: 125KHz EM card
Wiegand 26~37 bits input & output
Can be used as Wiegand reader with LED & Buzzer output
Card block enrolment
Tri-colour LED status display
Integrated alarm & buzzer output
Pulse mode or Toggle mode
User data can be transferred
2 devices can be interlocked for 2 doors
Built in light dependent resistor (LDR) for anti tamper
Backlit keypad
Low temperature resistance (-40℃)
Voltage: 12~28V AC/DC

3
Specifications
User Capacity
Common User
Panic User
1000
998
2
Operating Voltage
Idle Current
12~28V AC/DC
<35mA
Proximity Card Reader
Radio Technology
Read Range
EM Format
125KHz Proximity Card
2~6 cm
Wiring Connections Relay Output, Exit Button, Alarm, Door Contact,
Wiegand Input, Wiegand Output
Relay
Adjustable Relay Output Time
Lock Output Load
One (NO, NC, Common)
0~99 Seconds (5 seconds default)
2 Amp Maximum
Wiegand Interface
Wiegand Input
Wiegand Output
Pin Output
Wiegand 26-37 bits
(Factory Default: Wiegand 26bits, 4 bits)
26-37 bits
26-37 bits
4 bits, 8 bits(ASCII), 10 digits Virtual Number
(Note: Set in the factory as 26 Bit Wiegand 10 Digit
Virtual No. If a factory reset is performed onsite then
these settings need to be manually reset.)
Environment
Operating Temperature
Operating Humidity
Meets IP66
-40℃~ 60℃(-40℉~ 140℉)
0%RH~98%RH
Physical
Colour
Dimensions
Unit Weight
Shipping Weight
Zinc-Alloy
Silver
L114.5 x W75 x D22mm(XK3)
L134 x W55.5 x D21mm (XK4)
340g
420g

4
Carton Inventory
INSTALLATION
Remove the back cover from the unit
Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
Knock the supplied rubber bungs to the screw holes(A,C)
Fix the back cover firmly on the wall with 4 flat head screws
Thread the cable through the cable hole(B)
Attach the unit to the back cover
Wiring
WireColor Function Notes
Basic Standalone Wiring
Red AC/DC 12-28V AC/DC Regulated Power Input
Black AC/DC 12-28V AC/DC Regulated Power Input
Pink GND Negative Pole
Blue Relay NO Normally Open Relay Output (install diode provided)
Purple Relay Common Common Connection for Relay Output
Orange Relay NC Normally Closed Relay Output (Install diode provided)
Yellow OPEN Request to Exit(REX) Input
Pass-Through Wiring (Wiegand Reader or Controller)
Green Data 0 Wiegand Input /Output Data 0
White Data 1 Wiegand Input /Output Data 1
Advanced Input and Output Features
Grey Alarm Output Negative contact for Alarm
Brown Contact Input Door/Gate Contact Input (Normally Closed)

5
Sound and Light Indication
Operation Status LED Buzzer
Stand by Red light bright -
Enter into programming mode Green light Flashes on, then
RED Light flashes.
One beep
In the programming mode Orange light bright One beep
Operation error - Three beeps
Exit from the programming mode Red light bright One beep
Open lock Green light bright One beep
Alarm Red light Shines quickly Beeps
Basic Configure
Enter and Exit Program mode
Set Master Code
Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #
2. Update Master Code 0(New Master Code)#(Repeat New Master Code)#
(Master code is any 6 digits)
3. Exit Program Mode *
Set the Working Mode
Notes: the XK Series device has 3 working modes: Standalone Mode, Controller Mode, Wiegand Reader Mode, choose
the mode you use. (Factory default is Standalone Mode / Controller Mode)
Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #
2. Standalone/Controller Mode
OR
2. Wiegand Reader Mode
7 2 # (Factory default)
7 3 # (Pre-Set in the factory after a ‘Factory default’)
3. Exit *
Programming Step Keystroke Combination
Enter Program Mode * (Master Code) #
(Factory default is 123456)
Exit Program Mode *

6
STANDALONE MODE
The XK Series device can be worked as Standalone Reader for single door. (Factory default mode)---7 2 #
Connection Diagram
Attention:
Install a 1N4004 or equivalent diode is needed when using a common power supply, or the keypad might be damaged.
(1N4004 is included in the packing)

7
Programming
Programming will vary depending on access configuration. Follow the instructions according to your access
configuration.
Notes:
User ID number: Assign a user ID to the access card / PIN in order to track it. The common user ID number can
be any number from 0~997, the panic user ID is from 998~999. IMPORTANT: User IDs do not have to be
proceeded with any leading zeros. Recording of User ID is critical. Modifications to the user require the User ID
be available.
Proximity Card:
EM version: 125KHz industry standard 26bits EM card
PIN: Can be any 4~6 digits except 8888 which is reserved.
Add Common Users
Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #
Add Card User
2. Add Card: Using Auto ID
(Allows XK Series device to assign Card to
next available User ID number)
OR
2. Add Card: Select Specific ID
(Allows Master to define a specific User ID to
associate the card to)
OR
2. Add Card: by Card Number
OR
2. Add Card: Block Enrolment
(Allows Master to add up to 998 cards to the
Reader in a single step)
Takes 2 minutes to program.
1 (Read Card) #
The cards can be added continuously.
1 (User ID) # (Read Card) #
(User ID is any number from 0-997)
1 (Input 8/10 digits Card number) #
1 ( User ID) # (Card quantity) # (The first
card number) #
Cards’ number must be consecutive;
Card quantity = number of cards to be enrolled.
Add PIN User
2. Add PIN: Using Auto ID
(Allows XK Series device to assign PIN to next
available User ID number)
1 (PIN ) #
The PINs can be added continuously.
(PIN: 4~6 digits)
2. Add PIN: Select Specific ID
(Allows manager to define a specific User ID
to associate the PIN to)
1 (User ID) # (PIN ) #
The user ID is any number from 0-997.
3. Exit *

8
Add Panic Users
Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #
2. Add Card:
OR
2. Add PIN:
1 (User ID) # (Read Card / Input 8/10 digits
Card number) #
1 (User ID) # (PIN ) #
(User ID is any number from 998-999)
3. Exit *
Change PIN Users
Programming Step Keystroke Combination
Note: Below is done outside programming mode, users can undertake this themselves
2. Change PIN: By Card
(There will auto allocate PIN(8888) to cards when
adding)
* (Read Card) (Old PIN) # (New PIN) #
(Repeat New PIN) #
2. Change PIN: By PIN * (User ID) # (Old PIN) # (New PIN) # (Repeat
New PIN) #
3. Exit ﹡
Delete Users
Programming Step Keystroke Combination
1. Enter Program Mode ﹡(Master Code) #
Delete Card User - Common
2. Delete Card - By Card
OR
2. Delete Card - By ID number
OR
2. Delete User - By Card number
2 (Read Card) #
The cards can be deleted continuously.
2 (User ID ) #
2 (Input 8/10 digits Card number) #
Delete PIN User - Common
2. Delete PIN – by PIN
OR
2. Delete PIN – By ID number
2 (Input PIN) #
2 (User ID ) #
Delete Panic User
2. Delete Panic Card User
OR
2. Delete Panic PIN User
2 (User ID ) #
2 (User ID ) #
Delete All Users
Delete All User 2 (Master Code) #
3. Exit ﹡

9
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #
2. Pulse Mode
OR
2. Toggle Mode
3 (1-99) # (factory default)
The relay time is 1-99 seconds. (1 is 50mS.)
(Default is 5 seconds)
3 0 #
Sets the relay to ON/OFF Toggle mode
3. Exit *
Set Access Mode
For Multi cards/ PINs access mode, the interval time of reading cards/inputting PINs cannot exceed 5 seconds, or else,
the XK Series device will exit to standby automatically.
Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #
2. Card access
OR
2. Card + PIN access
OR
2. Card or PIN access
OR
2. Multi cards /PINs access
4 0 #
4 1 #
4 2 #
4 3 (2~9) #
(Only after reading 2~9 cards or inputting 2~9
PINs, the door can be opened)
3. Exit *
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed card attempts (Factory is OFF). It can be set to deny access for 10
minutes after engaging or disengage only after entering a valid card/PIN or Master code.
Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #
2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set alarm time
6 0 # (factory default)
6 1 # Access will be denied for 10 minutes
6 2 #
5 (0 ~ 3) # (factory default is 1 minute)
Enter Master code # or valid user card /PIN to
silence
3. Exit *
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Ness Controllori di accesso IP
























