Netgenium AUG3201-IP Manuale utente

Net genium
AUG3201-IP
Conguration Guide ver 5.x

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 2
THE SPECIFICATIONS AND INFORMATION FOR THE HARDWARE
AND SOFTWARE PRODUCTS IN THIS MANUAL ARE SUBJECT TO
CHANGE WITHOUT NOTICE. ALL INFORMATION AND
RECOMMENDATIONS IN THIS MANUAL WERE ACCURATE AT THE
TIME OF WRITING BUT ARE PRESENTED WITHOUT WARRANTY OF
ANY KIND. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR
APPLICATION OF ANY PRODUCTS.
IN NO EVENT SHALL NETGENIUM SYSTEMS BE LIABLE FOR ANY
INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES,
INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR
DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO
USE THIS MANUAL.
Copyright © 2017, Netgenium Systems
All rights reserved.

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 3
This chapter describes how to set up the AUG3201-IP for connectivity to the
LAN and congure the unit in its environment.
Initial Network Setup
Connect the AUG3201-IP to a PoE capable network switch or via a mid-span
device.
To logon for the rst time, open a web browser and type the IP address of the
gateway in the address bar. Each unit is pre-congured with a default IP
address of 10.100.1.173 when it leaves the factory.
The default username and password are as follows:
Username: netgenium
Password: netgenium
The home page provides basic information on the unit such as software
version serial number etc. Navigation around the menu structure is via the tabs
shown at the top of the home page. Each tab redirects the browser to the
master page for the conguration section selected. In each section a sub menu
is accessible via the links on the left of the page.
1 Conguration

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 4
To set the gateways IP address:
Navigate to: Setup
Congure the options as described below then click the Apply button.
General
Device Name: The name for the device (usually a description of the location)
Network
]P Address: IP address of the device
Network Mask: Subnet Mask of the device
Default Gateway: Default Gateway for the device
Netgenium Primary PolicyServer: The IP Address of the primary
PolicyServer
Netgenium Secondary PolicyServer: The IP Address of the secondary
PolicyServer Registration Mode: Autonomous or registered with
PolicyServer
Registration Status: Current registration status.

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 5
DNS Settings
Domain Name. Not used.
Primary DNS. Not used.
Secondary DNS. Not used.
Time & Date
Navigate to: Setup>Time & Date
This page enables you to set the system time and date.
The options are:
Set to Computer Time: This option sets the time and date to that of your
computer when the Apply button is clicked.
Set Manually: Enter the time and date in the textboxes
provided and click the Apply button.
Use NTP: With this option enabled the controller will
synchronize its time and date with an NTP
server every 5 minutes.
Enter the IP Address of the NTP server and click
the Apply button.
If the controller is congured to register with PolicyServer the unit will
automatically be synchronised with PolicyServer’s date and time.
The system time has no signicance at all to the operation of the unit.
its only function is to provide a time stamp to any log entries.

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 6
Users
Navigate to: Setup>Users
Use this page to manage the accounts used to administer the unit.
The default settings are:
Username: netgenium
Password: netgenium
To add a new user account, enter the username and password and click the
Update button.
To remove an account, highlight the name to delete and click the Delete
button.
System
Navigate to: Setup>System
The system password is used to authenticate requests between
PolicyServer and the end devices.
The default setting is netgenium.

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 7
Gateway
Audio Out
Navigate to: Gateway
The Gateway tab gives access to General gateway settings and audio volume
settings

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 8
General
Mute Audio Mutes the audio output.
Announce IP on Boot The gateway will announce its IP Address
when it boots up.
PoE Plus Selects PoE+ mode. This will extend the
audio volume capability of the output.
Only select this setting if you have a
PoE+ power source.
TCP Audio Port Not used in Ver 5.
Audio Priority
The gateway supports 9 audio priorities (1-9). 1 is the lowest and 9 is the
highest. The default priority is 5.
Each priority level can be assigned its own volume setting.
If a gateway is making an announcement and it receives an announcement at
the same or lower priority it will be ignored. An announcement with a higher
priority will take precedence.
Audio Volume
Set the volume level for the desired priority with the slider and click the
Apply button.

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 9
Audio In
Navigate to: Gateway>Audio In
To congure an analogue audio input into the unit:-
1. Tick the Enable Audio Input and select the type of input used
(Line In or Microphone)
2. Use the Input Gain options to set the optimal gain setting for the input you
are using.
3. Connect the input device to the gateway and adjust the input gain.

geniumNet AUG3201-IP Cong Guide
© Copyright Netgenium Systems 2017 Page 10
Line In
Line In provides a low level analogue audio input to the gateway.
A signal input voltage of approximately 1 V is required. This input is not suitable
for a microphone.
Signal +, Signal - and Chassis GND terminals are provided for balanced and un-
balanced signals
Microphone In
Microphone In provides a low level analogue audio input to the gateway.
An input voltage of approximately 1 mV is required.
Signal +, Signal - and Chassis GND terminals are provided for balanced and un-
balanced signals
Line Out
Line Out provides a low level analogue audio output from the gateway.
A signal output voltage of approximately 1 V is supplied. This output is suitable
for an input to an analogue audio amplier
Signal +, Signal - and Chassis GND terminals are provided for balanced and
un-balanced signals
Line IN Mic IN Line OUT
-+-+-+
Indice