EN
English – 1
CONTENTS
1 GENERAL WARNINGS 1
2 PRODUCT DESCRIPTION AND INTENDED USE 2
3 ELECTRICAL CONNECTIONS 2
4 PROGRAMMING 4
4.1 “Slider” Function 5
4.2 LED 5
4.3 Transmitter recognition procedure 6
4.3.1 Using the “First Transmitter” (Empty Memory) 6
4.3.2 Using “Further Transmitters” Mode 1 7
4.3.3 Using “Further Transmitters” Mode 2 7
4.3.4 Using the “External Button” Mode 2 8
4.4 Memory deletion 9
4.4.1 Using the “Memorised Transmitter” 9
4.4.2 Using the “External Button” 9
4.5 Programming the brightness levels 10
4.5.1 Using the “Memorised Transmitter” 10
4.5.2 Using the “External Button” 11
4.6 Programming the locking and unlocking of the memory 11
4.6.1 Using the “Memorised Transmitter” 11
4.6.2 Using the “External Button” 12
5 Replacing a fuse 13
6 TECHNICAL SPECIFICATIONS 13
7 DISPOSAL OF THE PRODUCT 13
EC declaration of conformity 14
Instructions translated from Italian
ENGLISH 1 - GENERAL WARNINGS
• WARNING: Important safety instructions. Follow all instruc-
tions as improper installation may cause serious damage.
• ATTENTION: Important safety instructions. It is important for
you to comply with these instructions for your own and other
people’s safety. Keep these instructions.
• Children must not play with the appliance.
• Donotallowchildrentoplaywiththexedcontroldevicesofthe
product. Keep the remote controls away from children.
• Check the system frequently, especially check the wires for signs of
wear or damage. Do not use the device if it needs repair or adjust-
ment, because an installation failure can cause injury.
• Cleaning and maintenance that should be carried out by the user
must not be carried out by unsupervised children.
• ATTENTION: in order to avoid any danger due to inadvertent reset-
ting of the thermal cut-off device, this appliance must not be powered
through an external switching device, such as a timer, or connected
to a supply that is regularly powered or switched off by the circuit.
• Beforestartinginstallation,checkthe“Productspecications”(inthis
manual). If it is not suitable, DO NOT continue with the installation.
• The packing materials of the product must be disposed of in compli-
ance with local regulations.
• Before proceeding with the installation of the product, check that all
the materials are in good working order and suited to the intended
applications.
• The manufacturer assumes no liability for damage to property, items
or persons resulting from non-compliance with the assembly instruc-
tions. In such cases the warranty for material defects is excluded.
• Before working on the system (maintenance, cleaning), always dis-
connect the product from the mains power supply.
• Provide a disconnection device (not supplied) in the plant’s power sup-
ply grid, with a contact opening distance that permits complete discon-
nection under the conditions dictated by overvoltage category III.
• Handle the product with care during installation, taking care to avoid
crushing, denting or dropping it, or allowing contact with liquids of
any kind. Keep the product away from sources of heat and naked
ames.Failuretoobservetheabovecandamagetheproduct,and

EN
2– English
increase the risk of danger or malfunction. If this were to happen,
stop installation immediately and contact Customer Service.
2 - PRODUCT DESCRIPTION AND INTENDED USE
TTD0110 is a 1-10 Volt voltage regulator which drives the power out-
put of power supply units, with dimmer output, for lamps. Any other
use is improper and prohibited.
It is equipped with a radio receiver operating at a frequency of 433.92
MHz with “rolling code” encoding.
It can be controlled with Nice compatible products (Table 1) and with
an external push button to switch on and off and adjust the light inten-
sity of the lamp.
TABLE 1
Series Model Buttons Programming Function
Nice Era Era P Mode 1
(section 4)
Slider
(section 4)
Era W
Era MiniWay
Era One Mode 2
(section 4)
Era Inti
NiceWay NiceWay Mode 1
(section 4)
Nice Ergo Ergo
Nice Flor Flor-m Mode 2
(section 4)
Nice Very Very VR Mode 1
(section 4)
Nice
Home Touch HSTS2 display Mode 1
(section 4)
HSTX8 Mode 2
(section 4)
3 - ELECTRICAL CONNECTIONS
Special warnings:
• The product is subjected to hazardous voltage: therefore,
only open the housing and make connections with the power
switched off.
• Never cut the antenna cable, because it is subject to hazard-
ous voltage.
In order to make the electrical connections, you need to open the
TTD0110 (Fig. 1) and then proceed as shown in Fig. 2 and 3(complete
example of electrical connection):
1

EN
English – 3
2
112
ACNLAMP
V
V
+
-
+
-
DIM
DIM
ACL
L
P
N
2
3
4
5
6
7
3
supply voltage terminals
TTD0110 Input/Power
supply
220 - 240 Vac 7 - neutral N
6 - phase L
2 - earth T
External driver output/
power supply
5 - neutral N
4 - phase L
1 - earth T
Output/External button 3 - button P
7 - neutral N
low voltage terminals
Output/External driver:
adjustment 1-10 V or
0-10 V or 2-10 V or
PWM
dimmer connected to
power supply/driver 1 (-)
2 (+)
The product has two dip-switches (Fig. 4) that allow you to select the
type of load that will be connected to the output:

EN
4– English
112
2
3
4
5
6
7
1
ON
2
4
Dip 1 Dip 2 Description
Off Off Output 2-10 V
On Off Output 1-10 V
Off On Output 0-10 V
On On PWM (1k Hz)
Note:checkthetypeofloadinthetechnicalspecicationsofthede-
vice that is to be connected
4 - PROGRAMMING
The TTD0110 must be programmed with a transmitter memorised in
“Mode 1” or with the external button.
Up to 30 transmitters can be memorised in “Mode 1” or in “Mode 2”
in order to get different behaviours:
TABLE 2
Mode 1: automatically assign the three commands to the first three
buttons on the transmitter
Buttons Function
/ 1
2
3
4
Dimmer up
/
1
2
3
4
Toggle
/
1
2
3
4
Dimmer down
1
2
3
4... -
Mode 2: freely associate one command from among those available
Function Procedure Description
Dimmer up
1 short press
on the button
( < 1 second )
the brightness of the lamp increas-
es by a small percentage if it is not
already set to the maximum value
1 long press
on the button
( > 1 second )
the brightness of the lamp in-
creases until it reaches the maxi-
mum value set or until the button
is released
Toggle every time you
press the button
the dimmer turns the lamp On or
Off.
Brightness associated with “On”:
the last brightness value set on
the dimmer.
This value is memorised automati-
cally by the dimmer when the lamp
is switched off (i.e. the memorised
value will be the brightness of the
lamp before being switched off)
or, in any case, about 60 seconds
since the brightness was last ad-
justed (i.e. the last brightness value).
Dimmer down
1 short press
on the button
( < 1 second )
the brightness of the lamp decreas-
es by a small percentage if it is not
already set to the minimum value
1 long press
on the button
( > 1 second )
the brightness of the lamp de-
creases until it reaches the mini-
mum value set or until the button
is released
Dimmer up
Toggle
Dimmer down
...
every time you
press the button
the various functions are performed
alternately

EN
English – 5
4.1 - “Slider” Function
This allows you to turn the lamps On and Off and to adjust the bright-
ness dynamically. The capacitive strip acts like a slider:
Procedure Description
short touch on the slider absolute positioning command
sliding your nger on the
slider
progression of commands to adjust the
brightness dynamically: sending com-
mands regardless of where you place
your finger
4.2 - LED (Fig. 5)
The LED on the lower part of the TTD0110 sends various signals in the
programming procedures and some general signals:
Flashes Colour Execution Description
6green at the end of a
transmitter memori-
sation procedure
the memory is full:
the transmitter
cannot be memorised
2green when the dimmer is
powered
its memory is empty
(= no transmitter
memorised)
2red during any program-
ming procedure an error was
committed
on
fixed blue
it comes on when
the power supply
unit /driver is acti-
vated
voltage to terminals
5 and 4
5
In this manual the programming procedures are explained with the use
of icons and their meanings are shown in the table below:
KEY
LED: behaviour during the programming procedures
Symbol Description
ON
OFF
LONG ashing
SHORT ashing
FAST ashing
other symbols
Symbol Description
OFF
DISCONNECT POWER
LED red / green
LED blue

EN
6– English
ON
CONNECT POWER
LAMP ON
LAMP OFF
DESIRED VALUE
FOR THE BRIGHTNESS OF THE LAMP
PRESS BRIEFLY
PRESS AND HOLD THE BUTTON
ON THE TRANSMITTER
PRESS AND HOLD THE BUTTONS ON THE
TRANSMITTER AT THE SAME TIME
RELEASE THE BUTTON (OR THE BUT-
TONS) ON THE TRANSMITTER
---TRANSMITTER BUTTONS
1
2
3
4
-1
2
3
4
-
1
2
3
4
... TRANSMITTER BUTTONS
BRIEFLY PRESS THE DESIRED BUTTON
ON THE TRANSMITTER
PRESS AND HOLD THE DESIRED BUT-
TON ON THE TRANSMITTER
VIEW / SELECT
WAIT FOR...
2 seconds WAIT FOR A PRECISE TIME
BRIEFLY PRESS THE EXTERNAL BUTTON
PRESS AND HOLD THE EXTERNAL BUT-
TON
RELEASE THE EXTERNAL BUTTON
4.3 - Transmitter recognition procedure
4.3.1 - Using the “First Transmitter” (Empty Memory)
This procedure allows you to associate a transmitter to the dimmer in
“Mode 1”.
01.
OFF
2 seconds
ON
2
Green LED
02. within 5
seconds
for 8 seconds
03. 2green LED: memorising OK
2red LED: memorising NOT CONCLUDED
in this case, repeat the procedure from the beginning

EN
English – 7
4.3.2 - Using “Further Transmitters”: Mode 1
This procedure allows you to associate a transmitter to the dimmer in
“Mode 1”.
01. NEW
transmitter
for 8
seconds
1
red LED
02. OLD transmitter
already memorised x 3
03. NEW
transmitter
for 5 seconds
04. 2green LED: memorising OK
2red LED: memorising NOT CONCLUDED
in this case, repeat the procedure from the beginning
4.3.3 - Using “Further Transmitters”: Mode 2
This procedure allows you to associate a transmitter to the dimmer in
“Mode 2”.
01.
OLD
transmitter
already
memorised
for 8
seconds
1
green LED
02.
OLD
transmitter
already
memorised
for 8
seconds
2
green LED
03. OLD
transmitter
already memorised
select the desired function:
Dimmer Up > Toggle > Dimmer Down x 1
Dimmer Up x 2
Dimmer Down x 3
Toggle x 4
Level 1 x 5
Level 2 x 6
Level 3 x 7
Level 4 x 8
OFF x 9

EN
8– English
ON x 10
04.
5 seconds = ... green LED
no. of ... flashes according
to the chosen function
05. desire button on the
transmitter
green LED
3 sec. =
06. 2green LED: memorising OK
4.3.4 - Using “External Button”: Mode 2
This procedure allows you to associate a transmitter to the dimmer in
“Mode 2”.
01.
OFF
ON
green
LED
3 sec. =
02. green
LED 3 sec. =
at the the
03. select the desired function
Dimmer Up > Toggle > Dimmer Down x 1
Dimmer Up x 2
Dimmer Down x 3
Toggle x 4
Level 1 x 5
Level 2 x 6
Level 3 x 7
Level 4 x 8
OFF x 9
ON x 10
04.
5 seconds
green LED
no. of ... flashes according to
the chosen function
05. desire button on
the transmitter
green LED
3 sec. =
06. 2green LED: memorising OK
Indice
Lingue:
Altri manuali Nice Ricevitore

Nice
Nice FLO Series Manuale utente

Nice
Nice TT2Z Istruzioni operative

Nice
Nice NICEONE OXI SERIES Manuale del prodotto

Nice
Nice Apollo FLOR FLOXR Series Specifiche tecniche

Nice
Nice tt2d Manuale utente

Nice
Nice OXILR Manuale utente

Nice
Nice RB02 Manuale utente

Nice
Nice HSRE12 Manuale utente

Nice
Nice NiceOne OX4T Istruzioni operative

Nice
Nice FLOX1 Manuale utente

Nice
Nice OXIBD Manuale utente

Nice
Nice SMX2 Manuale del prodotto

Nice
Nice BIO Series Manuale utente

Nice
Nice OXILR Specifiche tecniche

Nice
Nice elero Revio-868 SW Manuale utente

Nice
Nice TT2N Specifiche tecniche

Nice
Nice FLOR Specifiche tecniche

Nice
Nice OXIBD Manuale utente

Nice
Nice RMF3004 Manuale utente

Nice
Nice TT2Z K Istruzioni operative