Nico Technology 3010L Manuale utente

3010L Power Controller User’s Manual
1 Rev.1.4
3010L Power Controller
Manual
Revision 1.4
Nico Technology Ltd.
24F,No.37,SanMin Rd, 2.Sec, PanChiao City, Taipei County, Taiwan
Phone +886-2-2954-5338
Fax +886-2-2954-5308
Technical Support Tom_Yeh@nico-tech.com
Web site http://www.nico-tech.com

3010L Power Controller User’s Manual
2 Rev.1.4
This Manual
This manual provides any required information for installation, configuration
and operation of the 3010L Power Controller.
It exclusively treats the handling of this device. It neither describes the
LonWorks technology by Echelon nor the LonMark profile implemented in
detail. More specific information concerning these subjects can be found in the
documentation of Echelon (www.echelon.com) and the LonMark
Interoperability Association (www.lonmark.org).
The first part of this manual provides a survey about the device and its
installation in chapters 1 to 3. The 2nd part describes the implemented
application for lighting control and its configuration possibilities. Chapter 4
contains a description of the firmware interface while chapter 5 describes the
implemented LonMark Objects in detail providing an outlook of the individual
objects, their tasks and their relevant configuration parameters.
Chapter 6 explains the basics required to connect the objects to each other.
This manual is relevant for all variants of the 3010L Power Controller where
applications for lighting and switch control are implemented.
This documentation is subject to modification at any time without prior advice. Nico does not take over any
responsibility for mistakes or inaccuracies in this documentation and eventually occurring consequences.
In any case Nico as well as its representatives and staff are not reliable for eventual defaults, damages caused
indirectly or during use, occurring due to the use or non-usability of the software or the accompanying documentation.
Nico is a registered trademark of Nico Technology Ltd.
Echelon, LON, LonMark, LonWorks and Neuron are registered trademarks of Echelon Corporation. Other name may
be registered trade marks of the respective companies.

3010L Power Controller User’s Manual
3 Rev.1.4
Contents
Contents .........................................................................................................................3
2 Product Information...............................................................................................4
2.1 Functional Elements...................................................................................4
3 Installation..............................................................................................................4
3.1 Warnings ....................................................................................................5
3.2 Mounting....................................................................................................6
3.3 Connections................................................................................................6
3.4 Software Installation..................................................................................7
4 Device Description.................................................................................................8
4.1 Hardware Survey .......................................................................................8
4.2 Operation and Display Elements ...............................................................8
4.3 Connection Pin Assignment.......................................................................8
4.4 Wiring Diagram .......................................................................................11
4.5 EMC.........................................................................................................12
4.6 Technical Specifications ..........................................................................13
4.7 Dimensions ..............................................................................................13
5 Application Software for Lighting Control..........................................................14
5.2 Interoperable Interface.............................................................................14
6 System Objects.....................................................................................................15
6.1 Node Object.............................................................................................15
6.2 Closed-Loop Actuator (CLA) Object.......................................................16
6.3 Open-Loop Sensor (OLS) Object ............................................................16
6.4 Nico Tech. Signal Input Switch Processor Object...................................17

3010L Power Controller User’s Manual
4 Rev.1.4
2 Product Information
2.1 Functional Elements
Figure 1.1 3010L Power Controller
No Description
0 Input AC power supply connection
1 Output channels for relay output
2 Connect to LonWorks network
3 Service Pin button and Service Pin LED indicator
4 Reset button and Reset LED indicator
5 Input channels of dry contact.
6 3 way by-pass switch forAuto/Manual OFF/Manual ON
2.2 Variants and Identifications
2.3 Scope of Delivery
3 Installation
This chapter first describes the installation of the device; the installation of the
configuration software is described in section 2.4.

3010L Power Controller User’s Manual
5 Rev.1.4
3.1 Warnings
Attention
The device must be installed in compliance with the relevant DIN/VDE
regulations or the relevant national standards. The connection to the
supply voltage must be performed in accordance with VDE 0100 and VDE
0160 or the relevant national standards. Installation should perform by
qualified and technical experienced personnel only.
CAUTION
At the connections of the output channels 1 – 4 (Fig. 1.1, terminals 7, 8, 9,
A) and the power supply (terminals 1, 2) 100-240V main voltage with load
guard band is accessible. The installation of the unit therefore has to be
effected in a switch cabinet or behind a respective cover.

3010L Power Controller User’s Manual
6 Rev.1.4
3.2 Mounting
3.3 Connections
The 3010L has to be connected to a 100-240VAC power supply and to the
LonWorks network.According to the respective application peripheral
equipment has to be connected to outputs.

3010L Power Controller User’s Manual
7 Rev.1.4
Attention
Before connecting peripheral equipment the power supply device has to be
switched off and by-pass switch has to be switch to manual off.
The connection is effected by means of the included plug-screw terminals.
Clamping range of the plug-screw terminals:
- High load connections (5.08mm grid, terminals 0 , 1): 0.2 – 2.5mm
- Low voltage connections (3.5mm grid, terminals 2 , 5 ): 0.14 – 1.5mm
The pin assignment of the connections is described in chapter 3.1, also
containing wiring details.
Voltage
The 100-240 Volt connections are through connected in order to achieve easy
wiring.
LonWorks Network
The connection to the LonWorks network is made by means of twisted-pair
cables. The connection “shield” has to be connected to ground in order to
achieve a reliable dissipation of over-voltage on the LON circuits.
Relay Outputs
The actors to be controlled are connected to the relay outputs. In each case
the connection is effected between terminals 1).
Attention
The 3010L input power supply must be same AC power phase.
3.4 Software Installation
The configuration software of the 3010L Power Controller has to be
installed by starting the program Setup.exe on the data carrier provided. It
suns under Windows 9x/2000 and NT.
Download url: http://www.nico-tech.com/download

3010L Power Controller User’s Manual
8 Rev.1.4
4 Device Description
The 3010L is a Power Controller for LonWorks network in building automation.
Its peripheral scope has been specially designed for the use as switch
controller for device spreading control of applications such as lighting control.
For the use in lighting the 3010L realizes 10 independent output channels with
ten relay output to control conventional switch.
For the use in sensor the 3010L realizes 10 independent input channels with
ten dry contacts for sensor input.
The LonMark object available per channel flexible use of the 3010L;
Furthermore there are several timer functions for the operation by switch
function. The configuration of the lighting control application is effected via a
plug-In.
Of course, the 3010L is also freeing programmable in Neuron C. As a flash
module is used the application can be load via the LonWorks network, making
the 3010L an I/O controller, e.g.
4.1 Hardware Survey
The 3010L disposes of ten output circuit for each. The output circuit can be
controlled individually relay output 8A.
4.2 Operation and Display Elements
The 3010L is fitted with a service button accessible via a small gap on the
front panel (see Figure. 1.1, 3).Activation of the buttons generates a
service-pin message transmitted via the LonWorks network. The
processor status as well as the service-pin status are displayed by the
service LED (figure. 1.1.3), which is on while the service button is activated.
By use the network management function Wink the service LED flashes.
Furthermore the 3010L is fitted with a reset LED (figure. 1.1, 4), displaying
the availability of device occur reset. The LED is connection to an I/O pin
of the Neuron chip processor.
4.3 Connection Pin Assignment
The following tables show the connector pin assignment of the individual
connectors. Connection the 1marking cf. Figure. 1.1 On previously page.

3010L Power Controller User’s Manual
9 Rev.1.4
In each clamp block pin 1 is situated on the left. For further wiring
information see chapter 3.4.
LonWorks Network Connection
The double-core bus line can be connection either to LON A or to LON B.
No polarity has to be considered by connecting the LonWorks network.
Figure 3.1 Connector pin assignment LonWorks network