Nikon P-THSS Manuale utente

P-THSS Teaching Head
P-THS Teaching Head Stand
P-THSS ティーチングヘッド
P-THS ティーチングヘッド用スタンド
Instructions
使用説明書


E-1
Thank you for purchasing the Nikon products.
This instruction manual is written for the users of the Nikon’s
“P-THSS teaching head and P-THS teaching head stand” and
describes their basic operations.
To ensure correct usage, read this manual carefully before
operating the instrument.
•It is prohibited to reproduce or transmit this manual in part or
whole without Nikon’s expressed permission.
•The contents of this manual are subject to change without notice.
•Although every effort has been made to ensure the accuracy of
this manual, if you note any points that are unclear or incorrect,
contact your nearest Nikon representative.
•Some of the products described in this manual may not be
included in the set you have purchased.
•Be sure to read the instruction manual for any other products
used in combination with the stand (such as the stereoscopic
microscope).
•P-THS teaching head stand can only be used with the
stereoscopic microscopes SMZ1500, SMZ1000 and SMZ800.

E-2
INames of Parts
Base
P-THS teaching
head stand
P-THSS
teaching head
Eyepiece tube mount for
the secondary observer
Eyepiece tube clamp
Eyepiece tube mount
for the main observer
Eyepiece tube clamp
Pointer mount
Screw hole for
attaching the epi-arm
Base leveling screw
Vinyl sheet
Vertical movement
clamp screw
Vertical movement
handle
Pillar
Pillar fixing screws
Focusing mount
clamp screws
Focusing mount
Focus knob
Teaching head
clamp screws

E-3
II Assembly
Required tools:
•Hexagonal wrenches (large / small)(supplied with the teaching head
stand)
•Hexagonal screwdriver (supplied with the teaching head stand)
•Hexagonal screwdriver (for mounting the pointer unit: M3)
•Minus screwdriver
1Attach the pillar to the base.
Use the large hexagonal wrench to securely
tighten the three screws.
2Attach the focusing mount to the pillar.
Slide on the focusing mount along the
dovetail mount on the pillar until it stops at
the limit pin. Tighten two clamp screws with
a minus screwdriver.
3Level the base.
Use the small hexagonal wrench to turn the
base leveling screw to stabilize the base.
Large hexagonal
wrench
Limit pin
Clamp
screws
Small hexagonal
wrench
Base
Base leveling screw
The pillar should
be attached here.

E-4
4Attach the teaching head.
Slide on the teaching head along the dovetail
mount on the focusing mount until it stops at
the limit pin. Tighten two clamp screws with
a minus screwdriver.
5Attach the stereoscopic microscope.
Attach the zooming body to the circular
dovetail mount at the bottom surface of the
main observer side of the teaching head, and
while pushing the zooming body toward the
front, tighten the clamp screw with a
hexagonal screwdriver. Be sure to hold the
zooming body with your hand until it is
securely clamped on to the teaching head.
6Attach the eyepiece tubes for the main
and secondary observers.
Matching the groove on the bottom surface of
the eyepiece tube with the pin on the mount,
attach the eyepiece tube on the teaching head.
Tighten the clamp screw with the hexagonal
screwdriver.
Limit pin
Clamp screws
(x2)
Push the
zooming
body
toward the
front and
clamp.
Pin
Groove

E-5
Assembly II
7Attach the eyepieces.
Insert the eyepieces into the eyepiece sleeves until they stop at the end
surfaces of the sleeves.
Note) The 10X eyepieces come with rubber covers. When attaching 10X
eyepieces to the eyepiece sleeves, do not hold the diopter
adjustment rings but hold their rubber covers to avoid damage to
the eyepiece. Also note that because of these covers, you cannot
check with your eyes that the eyepieces are securely inserted in
place. Feel through your fingers that they are securely inserted in
place.
8Screw on an objective to the zooming body.

E-6
III Usage
1How to Focus on the Sample
Loosen the vertical movement clamp screw and turn the vertical
movement handle to move up or down the teaching head.
Adjust the height of the teaching head so that the distance between the
objective end and the upper surface of the sample becomes almost the
same with the working distance of the objective in use. Tighten the
vertical movement clamp screw to fix the teaching head at that position.
Look into the eyepieces and turn the focus knob to precisely focus on the
sample.
●See the instruction manual supplied with the stereoscopic microscope
for the working distances of the objectives.
●Adjust the diopter before observation. See the instruction manual
supplied with the microscope for the details on the diopter adjustment.
●Avoid the following operations since they will damage the instrument.
•Turning the vertical movement handle without loosening the vertical
movement clamp screw.
•Turning the left and right focus knobs in opposite directions at the
same time.
•Turning the focus knob even after it reaches its limit of rotation.
Vertical movement clamp screw
Focus knob
Vertical movement
handle
Moves up
Working distance
of the objective

E-7
III
2Y-THP TH Pointer Unit
A guiding arrow can be shown in the right-side viewfield with the Y-THP
TH pointer unit mounted at the front of the main observer. Be sure to use
Y-THAC THAC adapter for the power supply of the Y-THP TH pointer
unit.
•When observing the sample of high reflectance, you may find several
arrow shadows in the left-side viewfield when you make the arrow very
bright. Though this is not a malfunction, you may need to darken the
arrow to make the shadows disappear.
1Mounting the pointer unit
Fix the pointer unit on the main observer side
of the teaching head with four screws using a
hexagonal screwdriver. Connect the Y-THAC
THAC adapter to the side of the pointer unit.
Connect the AC adapter to the wall outlet.
Lamphouse cover
Before replacing the lamp, turn off
the lamp with the arrow brightness
control (turn counterclockwise until
it clicks), unplug the AC adapter
from the wall outlet and wait till the
lamp cools down.
Arrow rotation dial
Turn to change the
arrow direction.
Arrow brightness control
(also functions as
the ON/OFF switch)
Turn clockwise to increase the
arrow brightness.
Turn counterclockwise until it
clicks to turn OFF the power
and to make the arrow
disappear.
Arrow control stick
Move to change the arrow position.
Arrow color selection dial
Turn to switch the arrow color between
G (green) and R (orange). This dial
should always be turned to the limit.
AC adapter plug

E-8
Groove
Lamphouse
cover
Protrusion
Luminous
part
Lamp
2Mounting (replacing) the lamp
To avoid electrical shock and burns, turn off the lamp with the arrow
brightness control (turn counterclockwise until it clicks), unplug the AC
adapter from the wall outlet and wait till the lamp cools down before lamp
replacement.
1Remove the lamphouse cover. (Push in
the cover and twist 45° to remove.)
2Insert the lamp into the socket with its
luminous part heading inside.
3Reattach the lamphouse cover.
(Matching the grooves with the
protrusions, push in and twist clockwise
till the limit.)
3Specifications
●Y-THP TH pointer unit
Type name: THP
Input voltage: DC 9V, 0.5A max.
Lamp for arrow illumination: 6V-0.2A tungsten lamp (average lifetime:
1000 hrs.)
Arrow color: Green or orange (can be selected)
Arrow illumination voltage: 0 to 6V (can be controlled by brightness
control which also functions as ON/OFF
switch)
Conforming standards: EU Low Voltage Directive satisfied.
EU EMC Directive satisfied.
●Y-THAC THAC adapter
Type name: SA-091A0F-10
Input voltage: AC 100-250 ~, 0.3A max.
Output voltage: DC 9V, 1A max.
Conforming standards: UL listed product
CSA satisfied.
EU Low Voltage Directive satisfied.
EU EMC Directive satisfied.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Nikon Attrezzature da laboratorio
Manuali Attrezzature da laboratorio popolari di altre marche

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manuale utente

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manuale utente

NI
NI PXI-5422 Manuale

Collomix
Collomix Aqix Manuale utente

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manuale utente

Ocean Insight
Ocean Insight FLAME-NIR+ Manuale utente