SYMBOL DEFINITIONS
The following table lists the symbols used in this document to denote certain conditions:
Symbol Definition
ATTENTION: Identifies information that requires special consideration
TIP: Identifies advice or hints for the user, often in terms of performing a task
REFERENCE _ INTERNAL: Identifies an additional source of information within the bookset.
CAUTION Indicates a situation which, if not avoided, may result in equipment or work (data) on the system being
damaged or lost, or may result in the inability to properly operate the process.
Indicates a situation where users must observe precautions for handling electrostatic sensitive devices.
!
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury. It may also be used to alert against unsafe practices.
!
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury or
death.


5 OPAL-RT Technologies OP5600/OP5650 User Manual
CONTENTS
RECEIVING AND VERIFICATION ........................................................................................................ 7
standard hardware ..............................................................................................................................................7
OP5600 SERIES/OP5650 SIMULATOR .................................................................................................. 8
INTRODUCTION .................................................................................................................................. 8
SIMULATOR ARCHITECTURE ............................................................................................................ 9
configuration options ..........................................................................................................................................9
Simulator Architecture Example...................................................................................................................................... 9
INSTALLATION AND CONFIGURATION ............................................................................................ 10
HARDWARE CONFIGURATION ......................................................................................................... 11
back connectors ............................................................................................................................................... 13
Connecting the Ground Screw...................................................................................................................................... 14
DB37F CONNECTIONS ..................................................................................................................... 15
OP5650 DB37 PIN ASSIGNMENTS .................................................................................................. 17
RJ45 CONNECTIONS ........................................................................................................................ 18
RJ45 CHANNEL ASSIGNMENTS ..................................................................................................... 19
connecting monitoring devices...........................................................................................................................20
SPECIFICATIONS ............................................................................................................................ 21
FLAT CARRIER SPECIFICATIONS .................................................................................................... 21
LIMITED WARRANTY............................................................................................................................ 23
Limited warranty .............................................................................................................................................. 23
return poLicy ...................................................................................................................................................23
excLusions ........................................................................................................................................................23
warranty Limitation and excLusion ....................................................................................................................24
discLaimer of unstated warranties ..................................................................................................................24
Limitation of LiabiLity ........................................................................................................................................24

OP5600/OP5650 User Manual OPAL-RT Technologies 6

7 OPAL-RT Technologies OP5600/OP5650 User Manual
Receiving and Verification
RECEIVING AND VERIFICATION
After opening the package, remove the equipment and components. Make sure that all the items
described in “standard hardware” are actually in the box and are undamaged.
standard hardware
The OP5650 real-time simulator includes the following basic hardware:
Item Description Part Number
OP5650 Simulator with Linux -based real-time O/S with PC
or OP5650-IO without CPU
System Integration binder CD (documentation, models, licenses)software CD
Integration documents
N/A
Mini-BNC cables (4) 2 m (6 ft 6”) adapter cables for mini-BNC to BNC. 75 Ohms
simplex
T00-0719
RJ45 cables (5) 61cm (24”) RJ45 cables BLACK
61cm (24”) RJ45 cables WHITE
61cm (24”) RJ45 cables RED
61cm (24”) RJ45 cables GREEN
305cm (120”) RJ45 cable BLUE
T00-0723
T00-0724
T00-0725
T00-0726
T00-0817
Synchronization cable Plastic optical fiber patch cord 3M T00-0811
DB37M breakout board Provides extended space for connections T00-4069
Loopback Kit DB37 TestBoard
Loopback Flat cable
Power cable
For Quick testing and Troubleshooting
126-0361
113-0737
113-0799
Power cable 1.83 m (6’) power cord, black (10A 125V)
Power Cord 6ft European (Schuko CEE7/7 to C13) - For Type E
and Type F
Power Cord 6ft Australia (AS3112 to C13) - Type I
Power Cord 6ft Brazil (NBR14136 to C13) - Type N
Power Cord 6ft China (GB2099 to C13) - Type I
Power Cord 6ft India (IS16A3 to C13) - Type D
Power Cord 6ft Switzerland (SEV1011 to C13) - Type J
Power Cord 6ft UK (BS1363 to C13) - Type G
T00-0833
T00-0783
T00-0784
T00-0795
T00-0775
T00-0794
T00-1836
T00-0848
Screws and rubber feet kit Extra if needed N/A
optional hardware
Item Description Part Number
MUSE transceiver Avago AFBR-57R5APZ T00-0315
MUSE cable LC-LC multimode 850nm optical fiber T00-0782
OPAL-RT strongly recommends the use of anti-static wrist straps whenever handling any electronic
device provided by OPAL-RT. Damage resulting from electrostatic charges will not be covered by the
manufacturer’s warranty.
Disconnect power before servicing
!
The OP5650 may be subjected to EMI when installed in proximity to other devices. Make sure to connect
the OP5650 ground to the rack to prevent any EMI related damage to the simulator.

OP5600/OP5650 User Manual OPAL-RT Technologies 8
OP5600 Series/OP5650 Simulator
Introduction
OP5600 SERIES/OP5650 SIMULATOR
INTRODUCTION
The OP5650 is a complete simulation system, that contains a powerful target computer, a
reconfigurable FPGA and signal conditioning for up to 256 I/Os. The design makes it easy to use with
standard connectors (DB37, RJ45, SFP and mini-BNC) without the need for input/output adaptors and
allows quick connections for monitoring I/O signals. It is designed to be used either as a desktop, shelf
top, or mounted in a standard 19’’ rack.
The front of the chassis provides access to the target computer’s standard connectors, and monitoring
interfaces and connectors, while the back of the chassis provides access to the I/O connectors, power
cable and main power switch.
Inside, the main housing is divided into two sections, each with a specific purpose:
In its standard configuration, the lower part of the chassis contains a powerful target computer that
can be added to a network of simulators or can act as a standalone. The target computer used to run
simulations built with OPAL-RT’s RT-LAB or HYPERSIM software simulation platform includes the
following features:
• ATX motherboard
• Linux-based real-time operating system
• Xeon E5 Intel CPU with 4, 8, 16 and 32 processor cores, up to 3.2GHz
• 10MB Cache Memory per 4 cores
• up to 32GB of DRAM,
• 512GB SSD disk,
• Space to install 2 PCI with risers, or 3 PCIe boards.
• Power consumption: 600W Max.
The upper section contains the high-speed FPGA and the conditioning modules for up to 256 I/Os. The
main features include:
• Xilinx Artix 7 FPGA 200T, programmable from the target computer via PCIe or MUlti-System
Expansion (MUSE). The FPGA is used to execute models designed with the OPAL-RT RT-XSG
tool, and manage the I/O lines. It exchanges data with the real-time simulations running on the
target computer CPUs via the PCIe link.
• Flat carrier capable of connecting any combination of up to 8 type B mezzanine boards.

9 OPAL-RT Technologies OP5600/OP5650 User Manual
OP5600 Series/OP5650 Simulator
Simulator Architecture
SIMULATOR ARCHITECTURE
configuration options
The OP5650 is available in a number of different configurations that make it easier to integrate into your
environment:
Product Configuration Description
OP5650-4 OP5650 RCP/HIL Artix 7 FPGA-based Real-Time Simulator - 4 cores (4U, Xeon E5, 4 Cores, 3.0 GHz,
10M, 16GB, 512GB SSD)
OP5650-8 OP5650 RCP/HIL Artix 7 FPGA-based Real-Time Simulator - 8 cores (4U, Xeon E5, 8 Cores, 3.2 GHz,
20M, 16GB, 512GB SSD)
OP5650-16 OP5650 RCP/HIL Artix 7 FPGA-based Real-Time Simulator - 16 cores (4U, Xeon E5, 2x8 Cores, 3.2 GHz,
2x20M, 2x16GB, 512GB SSD)
OP5650-32 OP5650 RCP/HIL Artix 7 FPGA-based Real-Time Simulator - 32 cores (4U, Xeon E5, 2x16 Cores, 2.3
GHz, 2x40M, 2x16GB, 512GB SSD)
Simulator Architecture Example
The example shown is only to illustrate how the OP5650 is assembled. OPAL-RT strictly prohibits users
from opening the OP5650. Opening the unit will render the warranty null and void.
Signal conditioning
modules
Carrier board
OPAL-RT
Artix 7
FPGA board
Lower section
Target Computer
Upper section
optional rackmount rail
Figure 1: OP5650 with target computer

OP5600/OP5650 User Manual OPAL-RT Technologies 10
OP5600 Series/OP5650 Simulator
Installation and Configuration
INSTALLATION AND CONFIGURATION
Follow this simple installation procedure. Make sure to respect proper grounding, as described in
“Connecting the Ground Screw”.
1. Place the OP5650 on a shelf or a desktop, or install in a traditional rack
2. Connect the power cable to the nearest power outlet
3. Connect the OP5650 to the same network used by the host PC, using the cables provided.
Figure 2: Top view of mezzanines installed on carrier
The top of the chassis can be removed to access the signal conditioning mezzanine boards installed on
the carrier board. The layout and configuration of the boards depends on the selected platform (which
must be factory installed):
At power-up, the carrier will autodetect installed mezzanines and transfer information to the FPGA and
the simulator.
CAUTION The system must be powered down before changing mezzanines. Failure to do so may
damage the equipment.
!
Disconnect power before servicing
Questo manuale è adatto per i seguenti modelli
5
Indice
Altri manuali Opal-RT Interruttore