OXO Simoun 2 R Manuale utente

INSTRUCTION MANUAL
MODE D’EMPLOI
FOR YOUR OWN SAFETY, PLEASE READ THIS INSTRUCTION MANUAL
CAREFULLY BEFORE YOU INITIALLY START-UP
POUR VOTRE SÉCURITÉ, MERCI DE LIRE ATTENTIVEMENT
CE MODE D’EMPLOI AVANT D’UTILISER VOTRE PRODUIT
V1.3 11/2021
Simoun 2 [R]


ENGLISH
SIMOUN 2 - USER INSTRUCTION Page
1. In the box 4
2. Instructions 4
3. Overview 5
4. Operation guide 6
5. Technical Specifications 10
FRANÇAIS
SIMOUN 2 - MODE D’EMPLOI Page
1. Dans la boîte 12
2. Instructions 12
3. Vue d’ensemble 13
4. Guide d’utilisation 14
5. Spécification techniques 18

Mode d’emploi - SIMOUN 2 [R] V1.3 11/2021 4/20
1. In the box
• 1 Simoun 2
• 1 External fader
2. Instructions
• WARNING
Read the instruction in this manual carefully and thoroughly, as they give important informa-
tion regarding safety during use and maintenance. Keep this manual with the unit, in order to
consult it in the future. If the unit is sold or given to another operator, make certain that it always
has its manual, to enable the new owner to read about its operation and relative instructions.
Protect the unit from excessive dryness or humidity (ideal conditions are between 35% and
80%).
To prevent fire or shock hazard, do not expose this product under a high temperature or humi-
dity area.
DO NOT make any inflammable liquids, water or metal objects enter the unit.
Should any liquid be spilled on the unit, DISCONNECT the power supply to the unit immediately.
This product must be earthed.
Take care not to damage the power cord.
After having removed the packaging check that the unit is NOT damaged in any way. If in doubt,
DON’T use it and contact an authorized dealer.
NEVER use the unit under the following conditions:
- In places subject to excessive humidity.
- In places subject to vibrations or bumps.
- In places with a temperature of over 45 C/113 F or less than 2 C/35.6 F.
DO NOT open the unit--there are no user serviceable parts inside.
NEVER try to repair the unit yourself. Repairs by unqualified people could cause damage or
faulty operation. Contact your nearest dealer.
Wait for at least one second to turn on the power after turning off this unit.
This unit is intended for indoor use only.
Packaging material (plastic bags, polystyrene foam, nails, etc.) MUST NOT be left within child-
ren’s reach, as it can be dangerous.
STOP using the unit immediately In the event of serious operation problems and either contact
your local dealer for a check or contact us directly.
DO NOT dismantle or modify the unit.
If in doubt, DON’T use it and contact an authorized dealer.
This unit must only be operated by adults. DO NOT allow children to tamper or play with it.

Mode d’emploi - SIMOUN 2 [R] V1.3 11/2021 5/20
3. Overview
1.1 Front Panel
1
2
5
6 3 4
1. Output 10 A max.
2. Segment Display Shows current activity or function state.
3. Menu button Press to enter next level.
4. Up button Each tap will increase the value once.
Pressing and holding down will increase quickly.
5. Down button Each tap will decrease the value once.
Pressing and holding down will decrease quickly.
6. HTP Slider This slider adjusts channel lighting intensity and complies with HTP
principle(Highest takes precedence).

Mode d’emploi - SIMOUN 2 [R] V1.3 11/2021 6/20
1.2 Rear Panel
Risk of Electri c Shock
Ne pas ouvrir. Risque de choc electriqu e
Warning: This apparatu s must be earthed
Made in China
1. Power Cord Plug in the appropriate power outlet.
2. Fuse F10A 250V 5x20mm
3. DMX In 3-pin XLR male socket, used to receive DMX data.
4. DMX Out 3-pin XLR female socket, used to send DMX data.
4. Operation Guide
General
Plug in the appropriate power outlet, this unit recovers to the function state of last time automa-
tically by reasons of power failure memory, and the Segment Display shows the DMX address
of last change. If the frequency of power is not stable, the Segment Display will show «AC-0»,
wait until the power is stable.
This unit serves as a dimmer pack or a switch pack, depending on operating
mode you’ve selected.

Mode d’emploi - SIMOUN 2 [R] V1.3 11/2021 7/20
2.1 DMX Address Mode
.8:8:8:8
ME NU
1. The Segment Display shows the DMX address of last
change when powered this unit.
If you’ve selected DMX address 123 for the last
time, then the Segment Display will read 123.
.8:8:8:8
ME NU
2. Each tap of the Up or Down button will change the DMX
address once. Pressing and holding down will change the
DMX address quickly.
Once the DMX address is selected, it will be
stored into memory automatically.
NOTE: During DMX addressing, output is disabled.
2.2 Switch Pack Mode
.8:8:8:8
1. When DMX address is complete, Press Menu button to
enter next level.

Mode d’emploi - SIMOUN 2 [R] V1.3 11/2021 8/20
.8:8:8:8
2. Tap the Up or Down button causing the Segment Display
shows «s---».
.8:8:8:8
3. Press Menu button to enter Switch Pack mode.
Switch Pack mode consists of Switch On(S-on)
and Switch Off(S-of).
In the Switch On mode, output is turned on and
the fixture lights regardless of DMX signal.
In the Switch Off mode, output is turned off and the fixture
is controlled by DMX signal. When DMX level is less than
40%, the fixture goes out; when DMX level exceeds 40%,
the fixture lights.
.8:8:8:8
4. Tap the Up or Down button to change between Switch On
and Switch Off.
5. Once the Switch Pack is selected, press Menu button to
return to DMX Address mode.

Mode d’emploi - SIMOUN 2 [R] V1.3 11/2021 9/20
2.3 Dimmer Pack Mode
1. Press Menu button to enter next level.
.8:8:8:8
2. Tap the Up or Down button causing the Segment Display
shows «d---».
3. Press Menu button to enter Dimmer Limit mode.
4. Tap the Up or Down button to change the value within
the range of 10-100. Each tap will change the value once,
pressing and holding down will change the value quickly.
Once the Dimmer Limit is selected, it will be
stored automatically.

Mode d’emploi - SIMOUN 2 [R] V1.3 11/2021 10/20
5. Press Menu button to enter Dimmer Preset mode.
6. Tap the Up or Down button to change the value within
the range of 00-100. Each tap will change the value once,
pressing and holding down will change the value quickly.
Once the Dimmer Preset is selected, it will be
stored automatically.
7. Press Menu button to return to DMX Address mode.
5. Technical Specifications
Power Input AC 230V~50Hz, 10 A max
Channel Output 10 A max
DMX OUT 3-pin XLR female socket
DMX IN 3-pin XLR male socket
Fuse F10A 250V 5x20mm
Dimensions 182x92x65mm
Weight 1.1 Kg
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue: