Perle IOLAN SDG1 W Manuale

IOLAN SDG1 W Hardware Installation Guide
Updated: Sept. 1,2019
Version A.1-09.01.2019
Document Part#:5500412-10(Rev C)
www.perle.com

IOLAN SDG1 W Hardware Installation Guide
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS GUIDE ARE SUBJECT TO CHANGE
WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS GUIDE ARE BELIEVED TO BE
ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE
FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in
accordance with this hardware guide may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own
expense.
Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product.
Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
Perle, the Perle logo, and IOLAN SDG1 W are trademarks of Perle Systems Limited.
©2019. Perle Systems Limited.

Table of Contents
Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
IOLAN SDG1 W (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IOLAN SDG1 W (Side Views) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ethernet and Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Button/Switch Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ethernet Port Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Connecting the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Connecting the Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Connecting Data Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Resetting the IOLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Resetting the IOLAN to Factory Default Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Configuring the IOLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Appendix A - Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Appendix B - Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Appendix C - Sample Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Appendix D - Cabling and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Appendix E - IOLAN Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Contacting Perle Systems Limited . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

2
IOLAN SDG1 W Hardware Installation Guide
Hardware
Preface
Audience
This guide is for the network or computer technician responsible for installing the Perle
IOLAN SDG1 W. Familiarity with the concepts and terminology of Ethernet and local area
networks is required.
Purpose
This document describes the hardware and physical characteristics of the Perle IOLAN
SDG1 W. It covers hardware features as well as installation and basic configuration and
operation of the product. For detail information on configuring the various features of
the IOLAN please see the “IOLAN Secure User’s Guide”.
Document Conventions
This document contains the following conventions:
Most text is presented in the typeface used in this paragraph. Other typefaces are used to
help you identify certain types of information. The other typefaces are:
Note: Means reader take note: notes contain helpful suggestions.
Caution: Means reader be careful. In this situation, you might perform an action that
could result in equipment damage or loss of data.
Warning: IMPORTANT SAFETY INSTRUCTIONS
Means danger. You are in a situation that could cause bodily injury. Before you work on
any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Only qualified personnel should con-
nect power to this unit.

IOLAN SDG1 W Hardware Installation Guide
Overview
This guide provides information on installing and doing the initial configuration on the
IOLAN SDG1 W unit.
The IOLAN SDG1 W has one DB9 serial port.
IOLAN SDG1 W (Top View)

IOLAN SDG1 W Hardware Installation Guide
IOLAN SDG1 W (Side Views)
Ethernet and Serial Ports
10/100/1000Base-T Port
The Ethernet port provides the standard Gigabit Ethernet interface speeds of 10/100/
1000 Mbps through twisted pair (UTP) cables of up to 100 meters (328ft) in length.
Console / Serial Port
The IOLAN SDG1 W has one DB-9 serial port. The serial port can be used to connect a
serial device or a console. When used to connect a serial device, the port can operate in
EIA-232, EIA-422 or EIA-485 mode. When used to connect a console, the port can be
used to fully configure and manage the IOLAN. For details on how to connect to the
serial port see Connecting the Serial Port .
For details on the serial port pinout see Appendix D - Cabling and Connectors .
Button/Switch Functions
Reset Button
The inset “Reset” button will reboot the IOLAN if pushed in and released quickly. It will
reset the IOLAN to factory defaults if pushed in and held for more than three seconds.
For more details on the operation of the Reset button see “Resetting the IOLAN ”
Console / Serial DIP Switch
The serial port can act as a console port or a serial port. The mode of operation is deter-
mined by the position of the “console/serial port” DIP switch. The DIP is set in the fac-
tory to serial (up position). Unless you plan to attach a console to the IOLAN, leave the
DIP switch in the serial position. In console mode, this port can be used to provide access
to the IOLAN management function using the industry standard CLI command set (see
Console Port Mode ).
See the IOLAN Command Line Interface Reference Guide for a complete set of the com-
mands available via the console.

IOLAN SDG1 W Hardware Installation Guide
WPS Button
Insert a paper clip into the inset hole labeled as “WPS” and gently press inwards. Pressing
this button for less than 3 seconds will put the IOLAN SDG1 W in WPS mode, greater than
4 seconds will put the unit in Soft-AP mode.

IOLAN SDG1 W Hardware Installation Guide
LED Indicators
Power/Ready
Link 10/100/1000
WPS (Wi-Fi Protected Mode)
Soft-AP Mode (Access Point Mode)
State Description
Green - solid System Ready
Green - flashing System is booting or dip
switch is in console mode
Amber - flashing System is booting
Off Error condition
State Description
Green 1000 Mbps (flashes with
activity)
Green/Amber 100 Mbps (flashes with
activity)
Amber 10 Mbps (flashes with
activity)
Off No LAN connection
State Description
Amber - flashing The first LED within the
signal strength display will
pulse amber on and off
State Description
Green - flashing The third LED within the
signal strength display will
pulse green on and off

IOLAN SDG1 W Hardware Installation Guide
WLAN
Signal strength
Ethernet Port Status Indicators
Port Link / Speed
State Description
Green-solid A wireless connection has
been established
Green-flashing Data is being transmitted
over the wireless network
Off No wireless connection
established
State Description
Amber/ Green Wireless signal strength from
amber LEDS to green LEDS
with green being the
strongest signal strength
State Description
Green 1000 Mbps (flashes with
activity)
Green/Amber 100 Mbps (flashes with
activity)
Amber 10 Mbps (flashes with
activity)
Off No LAN connection

IOLAN SDG1 W Hardware Installation Guide
Installation
General Cautions and Warnings
Warning: Power sources must be off prior to beginning the power connection steps.
Read the installation instructions before you connect the unit to its power source.
Warning: Ensure that the voltage and current ratings of the intended power source are
appropriate for the IOLAN as indicated on the product label.
Warning: Ensure that the installation and electrical wiring of the equipment is performed
by trained and qualified personnel and that the installation complies with all local and
national electrical codes.
Warning: This unit should be installed in a restricted access location where access can
only be gained by service personnel or users who have been instructed about the reasons
for the restrictions applied to the location and about any precautions that shall be taken;
and access is through the use of a tool or lock and key, or any means of security, and is
controlled by the authority responsible for the location.
Warning: If the unit is installed vertically in a living or office environment, the device
must be operated exclusively in cabinets with fire protection characteristics in accor-
dance with EN-60950-1
Warning: The working voltage inputs are designed for operation with Safety extra low
Voltage (SELV). Connect only to SELV circuits with voltage restrictions in line with IEC/EN
60950-1:2005 (2nd Edition) + A1:2009 and EN 60950-1: 2006 + A11:2009
Warning: If this equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Warning: Transient protection shall be provided that is set at a level not exceeding 140%
of the peak rated voltage value at the supply terminals to the equipment.
Altri manuali per IOLAN SDG1 W
1
Indice
Altri manuali Perle Interruttore

Perle
Perle IDS-509CPP Manuale

Perle
Perle IDS-205F Manuale utente

Perle
Perle IDS-509PP8 Manuale utente

Perle
Perle IDS-509GPP Manuale utente

Perle
Perle IDS-409-SFP Manuale

Perle
Perle IDS-105FE Series Manuale utente

Perle
Perle IDS-305F Manuale

Perle
Perle IDS-205F Manuale utente

Perle
Perle IDS-305F Manuale utente

Perle
Perle 07013340 Manuale

Perle
Perle IDS-509G2PP6 Manuale

Perle
Perle IDS-710 Manuale

Perle
Perle RPS830 Manuale utente

Perle
Perle IDS-509C Manuale

Perle
Perle IOLAN SDG4 W Manuale utente

Perle
Perle IDS-509F2 Manuale

Perle
Perle IDS-509-SFP Manuale

Perle
Perle IDS-205G Manuale

Perle
Perle IDS-509C Manuale utente

Perle
Perle IDS-205 Manuale utente