Pilz PZE 9 Manuale utente

PZE 9
Operating Manual 1001635-EN-05
}Safety relays

Preface
This document is a translation of the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for internal purposes. Suggestions and comments for improving this documentation will be
gratefully received.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries.
SD means Secure Digital

Contents
Operating Manual PZE 9
1001635-EN-05 3
Introduction 4
Validity of documentation 4
Using the documentation 4
Definition of symbols 4
Safety 5
Intended use 5
Safety regulations 5
Safety assessment 5
Use of qualified personnel 6
Warranty and liability 6
Disposal 6
For your safety 6
Unit features 7
Safety features 7
Block diagram/terminal configuration 7
Type: DC 7
Types: AC 8
Function description 8
Installation 9
Wiring 9
Preparing for operation 10
Operation 10
Status indicators 10
Faults – Interference 11
Dimensions in mm 11
Technical details 12
Safety characteristic data 23
Supplementary data 24
Service life graph 24
Order reference 25
EC declaration of conformity 25

PZE 9
Operating Manual PZE 9
1001635-EN-05 4
Introduction
Validity of documentation
This documentation is valid for the product PZE 9. It is valid until new documentation is
published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
Using the documentation
This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.
Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
NOTICE
This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

PZE 9
Operating Manual PZE 9
1001635-EN-05 5
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The contact expansion module PZE 9 meets the requirements of EN 60947-5-1, EN
60204-1 and VDE 0113-1. It is used to increase the number of contacts available on a base
unit. Base units are all
}Safety relays with feedback loop
}Programmable safety systems with feedback loop
The category that can be achieved in accordance with EN ISO13849-1 depends on the
category of the base unit. The contact expansion module may not exceed this.
The following is deemed improper use in particular:
}Any component, technical or electrical modification to the product
}Use of the product outside the areas described in this manual
}Use of the product outside the technical details (see Technical details [ 12]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a unit it is necessary to perform a safety assessment in accordance with the
Machinery Directive.
Functional safety is guaranteed for the product as a single component. However, this does
not guarantee the functional safety of the overall plant/machine. In order to achieve the re-
quired safety level for the overall plant/machine, define the safety requirements for the
plant/machine and then define how these must be implemented from a technical and organ-
isational standpoint.

PZE 9
Operating Manual PZE 9
1001635-EN-05 6
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.
A competent person is someone who, because of their training, experience and current pro-
fessional activity, has the specialist knowledge required to test, assess and operate the
work equipment, devices, systems, plant and machinery in accordance with the general
standards and guidelines for safety technology.
It is the company’s responsibility only to employ personnel who:
}Are familiar with the basic regulations concerning health and safety / accident preven-
tion
}Have read and understood the information provided in this description under "Safety"
}And have a good knowledge of the generic and specialist standards applicable to the
specific application.
Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended
}Damage can be attributed to not having followed the guidelines in the manual
}Operating personnel are not suitably qualified
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Disposal
}In safety-related applications, please comply with the mission time TM in the safety-re-
lated characteristic data.
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
For your safety
The unit meets all the necessary conditions for safe operation. However, please note the
following:
}Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120
VDC) are present on the unit, connected control elements and sensors must have a
rated insulation voltage of at least 250 V.

PZE 9
Operating Manual PZE 9
1001635-EN-05 7
Unit features
}Positive-guided relay outputs:
– 8 safety contacts (N/O), instantaneous
– 1 auxiliary contact (N/C), instantaneous
}LED display for:
– Supply voltage
– Switch status of the safety contacts
}Connection for feedback loop
}Operation: Single or dual-channel
}See order reference for unit types
Safety features
The unit meets the following safety requirements:
}The contact expander module expands an existing circuit. As the output relays are
monitored via the base unit's feedback loop, the safety functions on the existing circuit
are transferred to the contact expander module.
}The safety function remains effective in the case of a component failure.
}Earth fault in the feedback loop:
Detected, depending on the base unit that is used.
}Earth fault in the input circuit:
The output relays de-energise and the safety contacts open.
Block diagram/terminal configuration
Type: DC
}UB: 24 DC; Order no. 774150
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)

PZE 9
Operating Manual PZE 9
1001635-EN-05 8
Types: AC
}UB: 24 VAC; Order no. 774140
}UB: 42 VAC; Order no. 774141
}UB: 48 VAC; Order no. 774142
}UB: 110 - 120 VAC; Order no. 774143
}UB: 230 - 240 VAC; Order no. 774148
*Insulation against the non-marked area and between the relay contacts: Basic insulation
(overvoltage category III), protective separation (overvoltage category II)
Function description
The contact expansion module PZE 9 is an add-on device without delay-on de-energisa-
tion. It is used to expand a safety circuit. The contact expansion module is driven by a base
unit (e. g. emergency stop relay). When operating voltage is supplied the "POWER" LED
will light.
}Functional procedure once the input circuit is closed (e.g. safety contacts on the base
unit are closed):
– Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 and 83-84 close,
auxiliary contact 91-92 opens.
– The LEDs "CH.1" and "CH.2" illuminate.
}Functional procedure once the input circuit is opened (e.g. safety contacts on the base
unit are opened):
– Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 and 83-84 are
opened redundantly, auxiliary contact 91-92 is closed.
– The LEDs "CH.1" and "CH.2" go out.

PZE 9
Operating Manual PZE 9
1001635-EN-05 9
Installation
}The unit should be installed in a control cabinet with a protection type of at least IP54.
}Use the notch on the rear of the unit to attach it to a DIN rail.
}Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing ele-
ment (e.g. retaining bracket or an end angle).
Wiring
Please note:
}Information given in the "Technical details [ 12]" must be followed.
}Outputs 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74, 83-84 are safety contacts;
output 91-92 is an auxiliary contact (e.g. for display).
}Do not use auxiliary contact 91-92 for safety circuits!
}Do not connect undesignated terminals.
}To prevent contact welding, a fuse should be connected before the output contacts (see
Technical details [ 12]).
}Calculation of the max. cable runs lmax in the input circuit:
Rlmax
Rl / km
Imax =
Rlmax = max. overall cable resistance (see Technical details [ 12])
Rl/km = cable resistance/km
}Use copper wire that can withstand 60/75°C.
}Sufficient fuse protection must be provided on all output contacts with capacitive and in-
ductive loads.
}Do not switch low currents using contacts that have been used previously with high cur-
rents.
}On 24 VDC devices:
The power supply must comply with the regulations for extra low voltages with protect-
ive electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410.
}Ensure the EMC requirements of IEC 60204-1 are met.

PZE 9
Operating Manual PZE 9
1001635-EN-05 10
Preparing for operation
Supply voltage AC DC
A1
A2
L1
N
FE
A1
A2
L+
L-
Input circuit Single-channel Dual-channel
without detection of shorts
across contacts
K1
K2
U1
Y4
Y3
PZE
U2
K1
K2
U1
Y4
Y3
PZE
U2
with detection of shorts across
contacts
K1
K2
U1
Y4
Y3
PZE
U2
Feedback loop
Y1 and Y2 are feedback loop in-
puts on the base unit
Operation
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Status indicators
LEDs indicate the status and errors during operation:
LED on
POWER
Supply voltage is present.
Altri manuali per PZE 9
1
Indice
Altri manuali Pilz Staffetta

Pilz
Pilz PNOZ e1vp Manuale utente

Pilz
Pilz PNOZ 8 Manuale utente

Pilz
Pilz PNOZsigma Istruzioni per l’uso

Pilz
Pilz PNOZ X3.2 Manuale utente

Pilz
Pilz PNOZ X3 Manuale utente

Pilz
Pilz PNOZ X1P Manuale utente

Pilz
Pilz PNOZ X Series Manuale utente

Pilz
Pilz PNOZ e3.1p Manuale utente

Pilz
Pilz PNOZ s8 Manuale utente

Pilz
Pilz PZE X5 Manuale utente

Pilz
Pilz PNOZ mc0p Manuale utente

Pilz
Pilz PNOZ po3.3p Manuale utente

Pilz
Pilz PLID d1 Manuale utente

Pilz
Pilz PMD s10 Manuale utente

Pilz
Pilz PNOZ X2.4V Manuale del proprietario

Pilz
Pilz PNOZ s1 Manuale utente

Pilz
Pilz PSWZ X1P Manuale utente

Pilz
Pilz PNOZ X2.1C Manuale utente

Pilz
Pilz PNOZ XV2.1P Manuale utente

Pilz
Pilz S1IM 19540-3FR-04 Manuale utente