PNI SilverCloud 850VA Manuale utente

UPS SilverCloud 850VA
User manual / Manual de utilizare / Használati utasítás / Instrukcja obsługi / Manuale dell’utente

2
Before using this product, read all instrctions and markings.
SAFETY PRECAUTIONS
To use the device safely, please regard the following guidelines:
• Before using the device, read all instructions and warnings marked on ups, batteries and in the manual
• Only connect rechargeable batteries that were checked before. Connecting an old/used/faulty rechargeable battery
that does not respect initial parameters (charging/discharging) could result in defective functioning, and deterioration.
• To avoid possible explosions, charge only lead-acid rechargeable batteries
• Do not expose the product to rain, snow or liquids of any type. It is designed for indoor
• Do not disassemble it. Take it to a qualied service center when service or repair is required
• To avoid the risk of electric shock disconnect all wires from the device before cleaning or moving
• Careful attention to the handling of metal objects besides the battery. A short to battery may cause an explosion.
INTRODUCTION
The product is an intelligent voltage inverter with UPS function. The LCD screen provides useful information and easy access
to device settings, such as: battery charge current, battery charge voltage, output signal frequency, acoustic alerts on / o etc.
MAIN FEATURES
• Power 850VA / 600W
• Output in pure sinusoidal form
• LCD screen
• 3 steps charging algorithm
• Built-in AVR (automatic voltage regulator) function
• Overload and short circuit protection
• Deep discharge protection
• Cold start function
• Communication with PC
DEVICE DESCRIPTION
1. Power on
2. Power o
3. LCD screen
4. Bypass LED
5. AC input LED
6. Battery LED
7. AC output LED
8. Fault LED
9. ESC
10. SEL
11. ENTER
12. USB
13. Fan
14. AC input
15. AC output
16. Battery

EN
3
DISPLAY
Information displayed according to the selection
Charge level indicator (%)
Battery level indicator (%)
Disabled sound alerts
The on-screen information can be changed by pressing the “SEL” button, so you can view information about: input, battery,
output, load or temperature, as shown below::
Input Input voltage = 230 VAC
Frequency input signal = 50 Hz
Battery Battery voltage = 24.8 VDC
Battery current = 1A
Output Output voltage = 230 VAC
Frequency output signal = 50 Hz
Load Load = 579 W
Percent = 88 %
Temperature Temperature = 30 °C

4
INSTALLATION
Before installation, rst check that the device has not been damaged during transport.
Battery connection:
- Remove the covers of the external battery terminals
- Connect the battery to the polarity: the red cable at the battery terminal (+); the black cable to
the battery terminal (-)
NOTE: For user safety please use insulating tape on the battery connections before using the
device
INSTRUCTIONS FOR USE
ATENTION:IT IS MANDATORY THAT YOU TURN ON DEVICE AFTER PROCEDURE:
Turn on device: after you have plugged the power plug of the UPS into a 230V outlet, press and hold the power button to
turn on the device.
Turn o device: long press the shut down button to turn o the device.
The front panel contains an LCD screen and several LEDs that show how the device works.
Led indicators Messages
Backup mode
Line mode
Charger mode
All LEDs are o.
Low battery voltage
warning
Buzzing every 2 seconds and red LED
blinking
Overload warning Buzzing every 2 seconds and red LED
blinking
Fault mode Buzzing continuously and red LED is on
SETTINGS
Press the “ENTER” button for 2 seconds to enter the device setting mode. Press the “ENTER” button again to select the
desired setting option. Press the “SEL” button to change a parameter. Long press the “ESC” button to exit the setting mode.
All changes will take eect after the device restarts.
Option Description Values
04 Frequency signal 50 Hz (default) / 60 Hz
13 Bulk current 10 ~ 30A (default value 10A)
17 Absorption charge
voltage 13.8 ~ 14.5 V (default value 14.1 V)
Option Value

EN
5
18 Float charge voltage 13.5 ~ 13.7 V (default value 13.5 V)
19 Shutdown voltage 10.0 ~ 12.0 V (default value 10.5 V)
24 Alarme = enabled (default)
= disabled
25 Enable key tones = enabled (default)
= disabled
29 Grid charge enable = enabled (default)
= disabled
To reset all parameters to the default factory settings, press and hold the “SEL” button, select the “DEF” option then press the
“SEL” button again to conrm. Restart the device and the parameters will be reset.
OPERATING MODE DESCRIPTION
Operation mode Description Display
Fault mode
If an error occurs in the device’s
operating mode, it will automatically go
into error and its code will be displayed
on the screen
Charger mode In this way the external battery will be
charged
Line mode
In this way the output will feed directly
from the input and will charge the
battery at the same time.
If the input voltage has a value other
than the acceptable range (200
~ 240V), the AVR function will be
activated automatically. When the
input behaves abnormally, the device
automatically switches to battery mode.
Battery mode In this way the output will take o the
battery.
FAULT REFERENCE CODE
02 Over temperature 41 Input voltage too low
03 Battery voltage is too high 42 Input voltage too high
04 Battery voltage is too low 43 Input frequency too low
05 Output short circuited 44 Input frequency too high
06 Inverter output voltage is high 45 AVR fault
07 Overload 51 Over current
11 Main relay fault 58 Inverter output voltage is low

6
TROUBLESHOOTING
LED/sound alert Display Possible cause Solution
Only sound alert
“Battery” blinks Battery discharged Charge the battery
“LOAD” blinks Overload Remove one or more
consumers
Sound alert and red LED on Faut code 02 ~ 58
Check the description
of the error code in
the table above
Remove the source of
the error according to
the table above
TECHNICAL SPECIFICATIONS
Capacity 850VA / 600W
Input
Voltage range 140 ~ 280 VAC ± 5%
Frequency range 50Hz / 60Hz
Output
Battery mode 230 VAC ± 5%
Line mode 200 VAC ~ 240 VAC
Transfer time 6ms
Wave form Sine wave
Car battery
Voltage 12 V
Maximum charge current 20A
Capacity 30A - 200A
Other specications
Dimensions 420 x 280 x 225 mm
Weight 10.7 kg
Storage temperature -15 ~ +55 °C
Working temperature 0 ~ +40 °C
Noise ≤ 60 dB
Communication interface USB
Included accessories
Power cable 230V Yes
Battery terminals Yes
USB cable Yes
CD software Yes
CD software Da

RO
7
Va rugam sa cititi cu atentie acest manual inainte de utilizarea produsului.
INDICATII DE SIGURANTA
Pentru a utiliza dispozitivul in siguranta va rugam sa respectati urmatoarele indicatii:
• Inainte de a utiliza dispozitivul cititi toate instructiunile si atentionarile marcate pe UPS, baterie si in manual.
• Conectati doar acumulatori / baterii reincarcabile vericate in prealabil. Conectarea unui acumulator defect ce nu a fost
vericat si care nu mai respecta parametrii de functionare (incarcare/descarcare) poate duce la defectarea iremediabila
a ansamblului.
• Pentru a evita eventuale explozii incarcati doar baterii reincarcabile cu plumb acid.
• Nu expuneti dispozitivul la ploaie, zapada sau alte tipuri de lichide, el este destinat utilizarii doar la interior.
• Nu incercati sa desfaceti produsul, in caz ca acesta nu functioneaza corespunzator luati legatura cu un service autorizat.
• Pentru a evita riscurile de electrocutare deconectati toate rele de la dispozitiv inainte de a-l curata sau muta.
• Atentie mare la manipularea obiectelor metalice pe langa baterie. Un scurtcircuit la baterie poate cauza o explozie.
INTRODUCERE
Produsul reprezinta un invertor inteligent de tensiune cu functie de UPS. Ecranul LCD ofera informatii utile si acces facil la
setarile dispozitivului, cum ar : curentul de incarcare al bateriei, tensiunea de incarcare a bateriei, frecventa semnalului de
iesire, activare/dezactivare alerte sonore etc.
CARACTERISTICI PRINCIPALE
• Putere 850VA / 600W
• Iesire in forma sinusoida pura
• Ecran LCD
• Algoritm de reincarcare in 3 pasi
• Functie AVR (stabilizator de tensiune)
• Protectie suprasarcina si scurtcircuit
• Protectie descarcare brusca
• Functie de pornire la rece
• Port USB pentru monitorizare / Software gratuit inclus
DESCRIERE DISPOZITIV
1. Buton pornire
2. Buton oprire
3. Ecran LCD
4. LED bypass
5. LED intrare AC
6. LED stare baterie
7. LED iesire AC
8. LED eroare
9. Buton ESC
10. Buton SEL
11. Buton ENTER
12. Port USB
13. Ventilator
14. Intrare AC
15. Iesire AC
16. Intrare baterie

8
ECRAN
Informatii asate in functie de selectie
Indicator nivel sarcina (%)
Indicator nivel baterie (%)
Alerte sonore dezactivate
Informatiile de pe ecran pot schimbate apasand butonul “SEL”, astfel puteti vizualiza informatii despre: intrare, baterie, iesire,
sarcina sau temperatura, dupa cum arata mai jos:
Input = Intrare Tensiune de intrare = 230 VAC
Frecventa semnal de intrare = 50 Hz
Battery = Baterie Tensiune baterie = 24.8 VDC
Curent baterie = 1A
Output = Iesire Tensiune de iesire = 230 VAC
Frecventa semnal de iesire = 50 Hz
Load = Sarcina Sarcina = 579 W
Procent = 88 %
Temperatura Temperatura = 30 grade C

RO
9
INSTRUCTIUNI DE INSTALARE
Inainte de instalare vericati mai intai daca dispozitivul nu a fost deteriorat in timpul
transportului.
Conexiune baterie:
- indepartati capacele terminalelor bateriei externe
- conectati bateria respectand polaritatea: cablul rosu la terminalul (+) al bateriei; cablul negru
la terminalul (-) al bateriei
NOTA: pentru siguranta utilizatorilor va rugam sa utilizati banda izolatoare pe conexiunile
bateriei inainte de a utiliza dispozitivul
INSTRUCTIUNI DE UTILIZARE
ATENTIE! ESTE OBLIGATORIE PORNIREA DISPOZITIVULUI DUPA PROCEDURA:
Pornire dispozitiv: dupa ce ati introdus stecherul de alimentare al UPS-ului intr-o priza de 230V apasati lung butonul de
pornire pentru a porni dispozitivul.
Oprire dispozitiv: apasati lung butonul de oprire pentru a opri dispozitivul.
Panoul frontal contine un ecran LCD si cateva indicatoare LED ce arata modul de functionare a dispozitivului.
Mod functionare Indicatoare
Mod baterie
Mod direct
Mod incarcare
Toate LED-urile sunt stinse.
Avertizare
baterie scazuta Bip la ecare 2 sec si LED-ul rosu clipeste.
Avertizare
supraincarcare Bip la ecare 2 sec si LED-ul rosu clipeste.
Mod eroare Sunet continuu si LED-ul rosu este aprins.
SETARI
Apasati butonul “ENTER” timp de 2 sec pentru a intra in modul de setari ale dispozitivului. Apasati din nou butonul “ENTER”
pentru a selecta optiunea dorita pentru setare. Apasati butonul “SEL” pentru a modica un parametru. Apasati lung butonul
“ESC” pentru a iesi din modul de setare. Toate modicarile vor avea efect dupa restartarea dispozitivului.
Optiune Descriere Valori disponibile
04 Frecventa semnal 50 Hz (implicit) / 60 Hz
13 Curent incarcare 10 ~ 30A (implicit este setat la 10A)
17 Tensiune incarcare sub absorbtie 13.8 ~ 14.5 V (implicit este setata la 14.1 V)
Optiune Valoare

10
18 Tensiune incarcare cand bateria este
aproape plina (oat) 13.5 ~ 13.7 V (implicit este setata la 13.5 V)
19 Tensiune minima baterie 10.0 ~ 12.0 V (implicit este setata la 10.5 V)
24 Alarma = activata (setare implicita)
= dezactivata
25 Sunete taste = activata (setare implicita)
= dezactivata
29 Incarcare in functie de consum = activata (setare implicita)
= dezactivata
Pentru a reseta toti parametrii la valorile implicite din fabrica apasati lung butonul “SEL”, selectati optiunea “DEF” apoi apasati
din nou lung butonul “SEL” pentru a conrma. Restartati dispozitivul.
MODURI DE FUNCTIONARE
Mod functionare Descriere Ecran
Mod eroare
Daca apare o eroare in modul de
functionare a dispozitivului aceasta va
intra automat in mod eroare iar codul
acesteia va asat pe ecran
Mod incarcare baterie In acest mod bateria externa se va
incarca
Mod direct
In acest mod iesirea isi va lua
alimentarea direct de pe intrare si va
incarca si bateria in acelasi timp.
Daca tensiunea de intrare are o alta
valoara fata de intervalul acceptat (200
~ 240V) se va activa automat functia
de AVR. Cand tensiunea de intrare se
comporta anormal, dispozitivul va trece
automat in mod baterie.
Mod baterie In acest mod iesirea isi va lua
alimentarea din baterie.
CODURI DE EROARE
02 Temperatura ridicata 41 Tensiune de intrare prea mica
03 Tensiune baterie prea mare 42 Tensiune de intrare prea mare
04 Tensiune baterie prea mica 43 Frecventa semnal intrare prea
mica
05 Scurtcircuit pe iesire 44 Frecventa semnal intrare prea
mare
06 Tensiune mare pe iesire invertor 45 Eroare AVR
07 Suprasarcina 51 Curent prea mare
11 Eroare releu principal 58 Tensiune mica pe iesire invertor
Indice
Lingue:
Altri manuali PNI UPS
Manuali UPS popolari di altre marche

Pylontech
Pylontech Victron & Pylontech US5000 Manuale utente

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuale utente

Mecer
Mecer ME-1000-WTU Manuale utente

Mustek
Mustek PowerMust 530(B) Plus Manuale di installazione e funzionamento

Emerson
Emerson Liebert NXL series Manuale utente

MAKELSAN
MAKELSAN BOXER SERIES Manuale utente