Proactive Protekt Take-A-Long 33400P Manuale utente

PROTEKT® TAKE-A-LONG
FOLDING ELECTRIC PATIENT LIFT
MODEL: 33400P
270 Washington Street
Mount Vernon, NY 10553
855-237-7622
www.proactivemedical.com
OWNER’S MANUAL
1

Thank you for choosing the Protekt® Take-A-Long Lift!
To better serve you, please record the following information:
Supplier Name:__________________________________________
Telephone:______________________________________________
Serial #:________________________________________________
Date of Purchase:________________________________________
INSPECT YOUR MERCHANDISE
Upon receipt of your patient lift, verify that all merchandise is complete
and free from any shipping damage. Refuse delivery if the packaging
appears to be badly damaged. If the merchandise is received damaged
or is missing components, contact the shipping company immediately
and file a claim.
For further assistance, contact your local dealer or Proactive Medical
Products at the following:
Proactive Medical Products
270 Washington Street
Mount Vernon, NY 10553
Tel: 855-237-7622
www.proactivemedical.com
2

a. Boom
b. Mast
c. Base
d. Spreader bar
e. Pendant
f. Actuator
g. Control box
h. Caster with brake
i. Front caster
j. Emergency Lowering Device
Features Chart:
Control box on/off and
emergency stop button
Control buttons
LCD screen
Battery pack
Charger connector
Battery release clip
Hand pendant connector
Lifting actuator connector
c
a
b
d
e
f
g
h
i
j
3

SAFETY INSTRUCTIONS
The Protekt® Take-A-Long 33400P patient lift reflects innovative state of
the art design to increase user mobility. Your Protekt® lift will provide years
of service if it is properly maintained as any piece of electrical/mechanical
equipment requires.
Please pay careful attention to the following important information
regarding the care, maintenance, and operation of the Protekt® Take-A-
Long 33400P patient lift. Carefully read these instructions before
assembling the lifter or attempting to lift any user with the device.
PLEASE NOTE THE FOLLOWING:
Special care must be taken with users/patients who cannot themselves
provide assistance while being lifted. (i.e. patients who are comatose,
spastic, agitated, or otherwise severely handicapped).
The Protekt® Lift 33400P should be used solely for transferring a user/
patient from one utility (beds, chairs, toilets, etc.) to another. The
patient lift should not be used for transporting or moving any patient
from one location to another location.
During lifting or lowering, whenever possible, always keep the base of
the lift in the widest position.
The base of the lift should be closed before moving the lift.
Do not roll casters over any object while the user/patient is in the sling.
Do not lock casters during lifting.
While being lifted in a sling, always keep the user/patient centered
over the base and facing the caregiver operating the lifter.
Maximum weight that can be safely lifted is 400 pounds.
Never leave the user/patient unattended during lifting.
The Protekt® Take-A-Long 33400P lift allows a person to be lifted
and transferred safely, with minimum physical effort provided by the
caregiver. Before attempting to lift anyone, please practice operating
the lift. Also prior to actual lifting, explain the lifting procedure to the
user/patient.
4

WARNING!
Do not attempt to transfer a patient without prior approval of the
patient’s primary caregiver. Also, do not transfer without having
studied the instructions and practiced operating the lift and sling
several times. Together with the patient’s doctor, nurse, or medical
attendant, select a sling that is both practical and comfortable.
The sling selected should be one that serves the needs of the
patient, while providing the patient with optimal safety. Never
interfere with the lift, unless instructed by the attendant. Have a
doctor, nurse, or medical attendant (experienced in the use of the
Protekt® Lift 33400P) present during the first few times the lift is
used to transfer a new user.
WARNING!
Proactive Medical slings are specially designed to be used in
conjunction with Proactive lifts. Do not use slings manufactured
by other companies with any of Proactive Medical’s equipment.
USING OTHER MANUFACTURER’S SLINGS ON THIS EQUIPMENT
IS UNSAFE AND MAY RESULT IN SERIOUS INJURY TO USERS
AND CAREGIVERS. PROACTIVE MEDICAL is not responsible for
any consequence resulting from the use of non-Proactive slings
on this equipment.
WARNING!
Do not put anything (e.g. cushion, pad, etc.) between the user and
the sling. This may cause the user/patient to slide out of the sling
and cause injury.
WARNING!
Avoid personal injury by making sure no children or pets are near
the Protekt® Lift 33400P while it is being used.
WARNING!
Avoid personal injury by making sure all extremities (such as
fingers, arms, legs, or feet) are clear of the lift mechanism while it is
in operation.
5

WARNING!
Avoid personal injury and possible damage to the Protekt® Lift
33400P by making sure the maximum weight limit of 400 lbs. is not
exceeded.
WARNING!
Replace any worn parts with only genuine Proactive Medical
parts. The patient lift parts are not interchangeable with parts
from other patient lift brands. Using other patient lift parts on
these products is unsafe and may result in serious injury to user
and caregiver. Proactive Medical is not responsible for any
consequence resulting from the use of non-Proactive parts and
components.
WARNING!
Avoid personal injury by making sure the battery charger is
disconnected before conducting any electrical inspection. Contact
your dealer if any electrical problem is detected.
WARNING!
Service and repair of this equipment should be performed only by
an authorized dealer. Proactive Medical is not responsible for any
consequence resulting from any unauthorized service or repair.
CAUTION
Avoid damage to the Protekt® Lift 33400P by keeping foreign
objects from coming into contact with the lift mechanism.
NOTE
Arrange all necessary items (lift, slings, commode chair or wheel-
chair) for a smooth procedure. The user/patient being transferred
should be positioned in the center of the bed before being
lifted, as well as when he/she is returned to the bed. Keep lifter base
widened and brakes unlocked during lifting.
6

ASSEMBLY INSTRUCTIONS
WARNING!
The lift is heavy! Therefore, avoid injury and DO NOT attempt to
remove the lift from the box without any assistance.
Assemble the patient lift in accordance with the following instructions:
Engage the brakes. Remove the Black Hand nut from the bottom of the
mast and QR pin from the bottom of the Mast and Base.
Pull the Mast, Boom and Spreader Bar to an upright position. Re-insert the
QR pin into the holes at the bottom of the Mast and then use the Black (no
tool) Hand Nut to secure the Mast in place and make sure the Hand Nut is
holding the Mast securely.
Step 1.Step 1.
7

B. Attach the top of the Actuator to the bracket on the Boom and
insert pin. Insert keeper ring through hole in pin to secure actuator to
upper bracket.
A. Remove another QR pin which is connected to the bottom of Actuator
and Boom. Leave the QR pin on Boom as below left picture.
Step 2.
8

Attach the Control Box to the Mast and tighten two screws.
Insert the Actuator plug into the Control Box.
Insert the Pendant plug into the Control Box.
NOTE:
Prior to using the Protekt® Lift 33400P, charge the batteries for 10-12 hours.
Pendant plug
Actuator plug
Step 3.
Step 4.
Step 5.
9

MAINTENANCE & INSPECTION CHECK LIST
The operator is to inspect the Protekt® Take-A-Long Lift 33400P prior to
each use. Check all bolts for tightness. Make sure the base can be
easily widened, and that all lift parts are in place. Make sure all
casters turn freely, and that the caster brakes can be engaged. Make
certain all necessary items (i.e. slings, wheel chairs, etc.) are accessible
and ready for use.
At least once a month, the lift should be thoroughly inspected by a person
qualified to recognize any signs of wear, and looseness of bolts or parts.
Replace any worn parts immediately.
To lubricate, place a drop of oil on the following points when the Protekt®
Lift 33400P is serviced and every month thereafter - Top of Mast,
Spreader Hinge, and Caster Axles.
10
Altri manuali per Protekt Take-A-Long 33400P
1
Indice
Manuali Sistema di sollevamento popolari di altre marche

Genie
Genie Z-60/34 Manuale utente

Screen Technics
Screen Technics INTERFIT Vertical Up Lift Manuale utente

Mortuary Lift
Mortuary Lift ULTIMATE 1000 Manuale utente

Custom Equipment
Custom Equipment Hy-Brid 3 Series Manuale di programmazione

Custom Equipment
Custom Equipment Hy-Brid Lifts 2 Series Manuale di programmazione

Hy-Brid Lifts
Hy-Brid Lifts HB-P3.6 Manuale di programmazione