Projecta PH125 Manuale utente

POWER-HUB
P/No. PH125
12 VOLT PORTABLE POWER STATION

2
WARNINGS
• Risk of explosive gas. Working in the vicinity of a lead-acid battery can be dangerous
• Batteries might release explosive gases during normal operation and charging
• Before using the product, read and follow the instructions carefully. Follow all
manufacturer’s instructions
• Do not smoke, use matches, use a cigarette lighter, or allow a spark or flame near
the battery
• Do not allow metal to bridge the battery posts. It may spark or short-circuit the battery
and cause an explosion
• Remove rings, bracelets, necklaces and watches when working with a lead-acid battery
• Before accessing the battery leads (Red for positive and back for negative), disconnect all
devices or power sources from the sockets and DC terminals of the Power-Hub
• Ensure correct polarity when connecting to the battery leads
• Do not submerge the product in water or expose to rain
• Not recommended to use the product for critical power backup application
• Designed to work with 12V lead acid batteries (including Calcium, Gel and AGM) only
• Not recommended to house, wet or normal car battery
• Do not insert objects into the sockets
ACKNOWLEDGEMENT
Thanks to Century Yuasa Batteries Pty Ltd and Mr Jason Hill who provided valuable help
and support in development of this product.

3
Overview
The Projecta Power-Hub (PH125) is a batty box which is designed to house high capacity
batteries, equipped with advanced battery fuel gauge. The Power-Hub provides all
the necessary connections to power portable fridges and electronic devices. It has the
following features.
• Suitable for popular deep cycle AGM lead acid battery
• 300W Pure Sinewave Inverter (no early shutdown issue)
• Provides 10 popular power outlets which include:
– 2 x 10A Accessory Sockets
– 2 x 15A Merit Sockets
– 2 x 2A USB Sockets
– 1 x 10A Engel Type Socket
– 1 x 50A Heavy Duty Socket
– 1 x DC Terminal for high current requirements
– 1 x 240V AC Outlet
• All outputs via Accessory, Engel Type, Merit and 50A Heavy Duty are protected by a
resettable fuse
• 2.4” full colour LCD display
• Configurable Low battery capacity and battery health alarm
• Using patented technology to monitor battery characteristics like battery state of charge
and state of health
• Glass reinforced plastic casing

4
QUICK START
1. Unscrew the top section of the unit with the Allen Key provided
2. Place the top section next to the main body of the unit
3. Place the battery into the main housing

5
4. Secure the battery with horizontal and vertical straps provided
5. Use the pre-cut packaging foam to secure the battery
6. Connect the black battery lead to the negative terminal of the battery

6
7. Connect the red battery lead to the positive terminal of the battery
8. Put the top section back onto the main body
9. Secure the top section with the screws provided

7
10. Press enter to acknowledge the Welcome message on the LCD screen
11. Enter the battery capacity in Ah
12. Enter value for the low battery alarm and Ah

8
13. Enter the value for battery health warning alarm in Ah
14. Fully charge the battery with any multistage battery charger (e.g. IC1000, PC1600 etc)
15. Disconnect the battery charger when the battery is full
16. Unit is ready to use

9
Part No. PH125
Inverter
Input Voltage Range 10.5V – 15.0 Vdc
Input Current ≤32A
Open Circuit Output Voltage 240±5% Vac
Full Load O/P Voltage 240±5% Vac
Output Frequency 50±0.5Hz
Continuous Output Power 300VA
Surge Output Power 600VA for 0.2s
Output Waveform Pure Sinewave
Protection
Overload with Auto-recovery 360 – 450VA
Input Overvoltage 15.5±0.5Vdc
LVD 10.5±0.2VDC
Reconnect Input Voltage after LVD 12±0.2VDC
Overtemperature Auto-recovery
Reverse Polarity By Fuse
Battery Fuel Gauge
Input Voltage Range 6.0 – 17.0 Vdc
Display Resolution
Current 0.1 A
Voltage 0.1V
Battery Capacity 0.1Ah
Type of Battery Supported Lead Acid
Power Outlets
2 x 10A Accessory Socket Resettable Fuse Protected
2 x 15A Merit Socket Resettable Fuse Protected
1 x 10A Engel Type Socket Resettable Fuse Protected
1 x 50A Heavy Duty Battery Connector Resettable Fuse Protected
1 x DC Terminal –
2 x 2A USB Ports Short-circuit protected
1 x 300VA AC Socket Overload and Short-circuit Protected
Physical Characteristics
Weight 5.5 kg
External Dimension 390mm (L) x 235mm (W) x 337mm(H)
Maximum Battery Dimension Allowed 230mm x 177mm x 338mm*
Operating Temperature 0 to 50oC
Compliance
EMC Certified to meet AS/NZS 61000.6.3
Safety Tested to meet AS/NZS 4763
SPECIFICATIONS
*See drawing over the page

10
Maximum Battery Dimension Allowed:
BATTERY GAUGE USER INTERFACE
MAIN MENU
MENU
Battery Settings
Alarm Settings
Display On Time Settings
Brightness
Exit
Function Description
Battery Settings Set Battery Capacity
Alarm Settings Set Low Battery Capacity and Battery Health Alarms
Display On Time Settings Set the LCD Display On Time (10 mins as default
on time)
Brightness Set the brightness of the LCD Display (50% as
default value)
Restart Learning Cycle Force Battery Gauge to restart Battery Profile
Learning Cycle
Exit Exit Menu Screen and return to Default Screen
Deep Cycle: 60–140Ah