Protect 800i C Manuale utente

PROTECTGLOBAL.COM
PROTECT 800i C™ / 1500i C™ is designed to protect the most common
premises. Private homes and garages, shops and stores, offices, and
small and medium-sized warehouses.
The two new Fog Cannons™ are built on the same platform, but one
is sized for several cubic meters of fog and can fire for longer than
the other. Many of the specifications are otherwise similar.
INSTALLATION MANUAL
EN - Version 1.0
Item no.: 22069_0001EN

PROTECT 800i C™I 1500i C™
2 I SECURED IN SECONDS
EN
INSTALLATION MANUAL
Content
1. Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Safe instructions and ‘best practice’ . .................... 4
3. Mounting . ....................................... 6
4. Connection and settings . ............................. 7
5. Test and hand over ................................. 12
6. Error messages and troubleshooting . .................... 14
7. Warnings ........................................ 17
8. Consequencesoftheuseofunauthorizeduidin
PROTECT Fog Cannons®.............................. 18
9. Warranty terms and exceptions . . . . . . . . . . . . . . . . . . . . . . . . 18
10.Approvalsandcertications . ........................ 19
11. APPENDIX
Manual for PROTECT IPCard™ ......................... 23

PROTECT 800i C™I 1500i C™
3 I SECURED IN SECONDS
1. Before you begin
1 2
3 4
Start by reading this manual - the included quick
guide cannot stand alone.
By now you should have completed our installation
course. That may be a requirement.
Read more at www.protectglobal.com/e-learning
Always use IntelliSuite™ V.2.50.0.0 and
IntelliConnector™ for the best, safest and fastest
installation with documentation.
For technical support, please contact the place
where you purchased the Fog Cannon™ machines
or nd help in this manual.
INSTALLATION MANUAL

PROTECT 800i C™I 1500i C™
4 I SECURED IN SECONDS
2. Safe instructions and best practice
INSTALLATION MANUAL
5 6
8
7b
9
Min. 10 cm
Min. 10 cm
To ensure the best possible coverage the fog
needs free passage.
The fog machine must be placed to ensure
immediate coverage of possible access points.
Avoid covering escape routes with security fog.
For horizontal mounting, place the fog machine as
shown in the picture
Min. installation distance from objects – 2.5 m.
7a Reduce the risk of sabotage by placing the Fog
Cannon™ as high as possible. At the same time, pro-
per placement provides the most effective security.

PROTECT 800i C™I 1500i C™
5 I SECURED IN SECONDS
INSTALLATION MANUAL
10
12 13
Z X
Y
Measurements for installation of the fog machine.
IMPORTANT! Disconnect power to the machine before
removing the metal case.
Avoid unintentional fog emission – remove the fluid
container during installation and service and/or press
the service button.
11 Minimum safety distance is 35 cm for people and
objects. Do not look directly into the nozzle at a
short distance - risk of scalding!
PROTECT 800i CTM
650 mm
190 mm
150 mm
13,5
PROTECT 1500i CTM
650 mm
190 mm
170 mm
18,5
X
Y
Z
KG

PROTECT 800i C™I 1500i C™
6 I SECURED IN SECONDS
3. Mounting
INSTALLATION MANUAL
14 15
Unpack the Fog Cannon™ from the cardboard box
and remove the metal case.
Now remove the mounting plate on the Fog Cannon™.
Start by disassembling the uid container.
16
18 19
17
Place the Fog Cannon™ on the attached mounting
plate. Important! Remember to screw the safety
screw back in before you continue working.
Cabling of PROTECT 800i C™ / 1500i C™.
One cable to the alarm system, and the other
cable to 115/130/230V power.
When mounting in corners, included corner brackets
must rst be screwed onto the back plate of the
machine.
Place and fasten the mounting plate to the wall or
ceiling with the necessary fastening to the base.
Remember to bring the cables from the wall/
ceiling out through the hole in the back of the plate.

PROTECT 800i C™I 1500i C™
7 I SECURED IN SECONDS
4. Connection and settings
Printed circuit board (PCB)
Voltage
PROTECT 800i C™PROTECT 1500i C™
230 V - 50 Hz 230 V - 50 Hz
Effect
PROTECT 800i C™PROTECT 1500i C™
1050 W 1350 W
Standby consumption after heating up
PROTECT 800i C™PROTECT 1500i C™
44 W 56 W
Standby consumption when heat is disabled
PROTECT 800i C™PROTECT 1500i C™
5-10 W 5-10 W
INSTALLATION MANUAL

PROTECT 800i C™I 1500i C™
8 I SECURED IN SECONDS
COM.
NC
NO
Fog Rly.
Fire
Disable
Sec.
Prim
Arm
Output
Tamper
Fault Rly.
Fluid Rly.
COM.
NC
NO
COM.
NC
NO
–
+
–
+
–
+
–
+
–
+
–
Fog CannonTM Alarm System
12 V +
0 V
Motion
PIR
Tamper
12 V
–
+
+
0 V
PIR
12 V
–
+
Zone Fog
Zone Fault
Zone Fluid
Zone Tamper
Disable Signal
Alarm Signal
Closed in daytime
Opens with alarm
Tamper
Motion
Connection to alarm panel (typical installation)
INSTALLATION MANUAL

PROTECT 800i C™I 1500i C™
9 I SECURED IN SECONDS
Dipswitch
DIP Function
1
Heat disable
ON = The heating element disconnects
if disable is activated
2Fog time
3 Fog time
4 Fog time
5Arm*
6 Primary*
7 Secondary*
8Fire-alarm delay **
9 Reserved. Leave in OFF position
10 Error indicator. ON = Beeper connected
* ON = normal open
OFF = normal closed
** ON = delay is active
Inputs
Tamper Potential-free switches activate (open) when the covers are removed. They can be used in the alarm
system’s tamper circuit.
12V Built-in 12V supply system that delivers 0.1A – mainly to supply the secondary circuit, e.g.
a PIR sensor.
ARM Can be activated permanently by selecting an active break signal and by not connecting anything to
the terminals.
Primary The primary trigger signal is normally taken from the alarm system and activated from it in case of a
break-in.
Secundary The secondary trigger signal is normally taken from a verifying sensor such as a room sensor or a door
switch.
DIS The disable function can be used to stop the Fog CannonTM when it is producing fog. The signal is con-
nected to the alarm, so the Fog CannonTM is disconnected when the alarm is disconnected.
Fire
Connection of 12 V DC, N/O signal from the re alarm system. In case of a re alarm this signal will
disconnect the Fog CannonTM as long as the signal is active. Also, the
Fog CannonTM will activate a sound signal and report an error on the system error relay.
INSTALLATION MANUAL

PROTECT 800i C™I 1500i C™
10 I SECURED IN SECONDS
PROTECT 800i C™
Dip settings Fog time Fog volume
Dip 2 Dip 3 Dip 4 m³
OFF OFF OFF demo -
ON OFF OFF 20 sec 350
OFF ON OFF 40 sec 700
ON ON OFF 60 sec 850
OFF OFF ON 60 sec + 1 min. 1000
ON OFF ON 60 sec + 5 min. 1275
OFF ON ON 60 sec + 10 min. 1900
Fog volume
In the tables below the fog volume mentioned is based on the industry standard of security fog. A
change in visibility is gained through longer/shorter time with fog (adjustment of the unit), more/less
Fog Cannons™ and/or different placing of the unit(s). It’s important to perform a test ring of the
installation - and not only rely on the calculation of cubic metres.
Total time in max. pulse mode = 11 min.: 60 sec. + pulse shots.
Total fog production = 1900 m3.
Total capacity in the uid container = 3 complete sequence in pulse mode.
INSTALLATION MANUAL
The reduction in visibility at 1m during the tests carried out during the NF&A2P 2 shield
certication (EN 50131-8: 2019 and RTC 50131-8) of the 800i C™ is 50 sec. for 150 m3and
1136 sec. for maintaining opacity up to 3m.