PSI VERSA-PAK P50 Scheda tecnica

Apartment Compactor
PSI Waste Equipment Services, Inc.
Safety, Operaon, and Installaon Manual
11/23/2020
v.P50BA

PSI Waste Equipment Services, Inc.
P50 Apartment Compactor
Table of Contents
Secon1—SafetyandResponsibilies
SafetyDecals‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐1‐2
SafetyandResponsibilies‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐3
Secon2—Installaon
SiteSpaceRequirements‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐4
Electrical/SlabRequirements‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐5
Secon3—Operaon
ChangingContainers‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐6
ControlPanel‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐7
NormalOperaonalCharacteriscs(Manual)‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐8
NormalOperaonalCharacteriscs(Auto)‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐9
FaultCondions‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐10
Secon4—Specificaons
Specificaons‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐11
Secon5—Maintenance
PartsDiagram‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐12
Lock‐OutTag‐Out‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐13
PreventaveMaintenance‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐14
HydraulicSchemac‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐15
ElectricalSchemac‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐16

PSI Waste Equipment Services, Inc.
P50 Apartment Compactor
IntroducƟon
ThankyouforchoosingtheP50fromPSIWasteEquipmentServices,Inc.TheP50isbuiltonafoun‐
daonof30yearsofexperiencebuilding,selling,installingandrepairingwasteequipment.PSIWaste
hasinstalled,repairedandrebuiltthousandsofcompactors.Weknowwhatworksandwhatdoesn’t.
Weknowwhatlastsandwhatdoesn’t.Wetookthebestideas,madethembeer,andbuiltthebest
twincylinderapartmentstylecompactoronthemarket.
Aboutthismanual
Thismanualprovidestheinstaller,ownerandoperatorwithinformaonneededtoinstall,maintain
andoperatetheP50compactor.Youmustalsocomplywithlocal,stateandfederalcodes.ARepair
Manualisavailableatwww.psiwaste.com/P50.html
Compliance
TheP50apartmentstylecompactorisbuilttomeetallANSIZ245.2(1)safetystandards.Pleaseinstall,
maintainandoperatethiscompactorinaccordancewiththismanual,applicablelocal,state,andfed‐
eralcodesandregulaons.IfyouhaveanyquesonsabouttheP50,pleasecallusat352‐742‐4774
Opt.2.
Pleasereadthisenremanualbeforeinstalling,operang,ormaintainingthecompactor!

P50 Apartment Compactor
PSI Waste Equipment Services, Inc.
SecƟon 1, Safety and ResponsibiliƟes1
Safety Decals
Replacementdecalsareavailableuponrequest.
Part#DescriponQty
300004CauonDoorClosed4
300005CauonFederalLaw2
300007CauonKeepOff/DoNotPlay5
300008CompactorSafetyRules‐English2
300010Danger208Volt
300013DangerConfinedSpaceLockOut4
300014DangerCrushing/ShearingHazard 6
300015DangerHazardsCompactor3
300017DangerLockOutPowerUnit1
300018DangerShock/ArcFlash1
300019DangerStartsAutomacally2
Locaon
Doors–insideandoutside
Feedareasandcontrols
Allsidesofcompactor
Feedareasandcontrols
Hopper–allsides
Hopper–allsides,insidedoors,accesspanel
Accesspanelsandadjacentsurfaces.
Controlpanelface(PowerUnit)
Controlpanelface(PowerUnit)
Areasofaccessandfeed
300012Danger460Volt
300011Danger220‐240Volt Controlpanelface(PowerUnit)1
300009CompactorSafetyRules‐Español Feedareasandcontrols2
ListofSafetyDecals
Pickuphookusedtosafelymove
compactorusingcraneorother
suitableliingequipment.
Note:Removeaerinstall.

PSI Waste Equipment Services, Inc.
P50 Apartment Compactor SecƟon 1, Safety and ResponsibiliƟes2
Safety Decals

P50 Apartment Compactor
PSI Waste Equipment Services, Inc.
SecƟon 1, Safety and ResponsibiliƟes3
Safety and ResponsibiliƟes
InstallerandServicePersonnel
Danger:Onlyqualifiedandauthorizedpersonnelshouldaempttoinstallorservicethiscompactor!
Highvoltagemaybepresent.Shockandarcflashexplosionhazards!WearproperPPE.SeeNFPA70E.
Usesafeworkpracces.
Readandunderstandthismanual
Installcompactorinconformancewithlocal,state,andfederalcodes
Ensurethecompactorisleinasafecondion
Ensurethismanualandkeysaregiventotheowner
Owner
Ensurethecompactorinstallaonconformswithalllocal,state,andfederalcodes.
Ensuretheuseandmaintenanceofthecompactorconformswithalllocal,state,andfederal
codesandregulaons.
Provideproperinstruconandtrainingtoemployees.
EnsureemployeesunderstandandfollowOperatorResponsibiliesandsafetydecals.
Ensureonlyauthorizedandqualifiedemployeeshaveaccesstothecompactor.
Properlymaintaincompactorandsurroundingareasprovidingadequatespaceforuseand
maintenance.
Ensurethecontainersusedwiththecompactorareadequatelyratedandfitproperly.
SeeANSIZ245.2fordetailedOwnerandOperatorResponsibilies.
Operator/Employee
Youmustbe18yrsoldoroldertooperatethiscompactor.
Donotusethecompactorunlproperlytrainedandauthorized.
Read,understandandfollowallsafetydecalsandthismanual.
Makesureallsafetyswitchesandsafeguardsareinplaceandworking.
Ensureallpersonsareclearofhopper,charge‐boxareasandendofcontainer.
Usethecompactorcarefullymaintainingawarenessofpotenalsafetyissues.
Reportanydamageormalfunconimmediately.
Ifcompactorisunsafetooperateuselockout/tagoutprocedurestoshutitdown(ifpossible)and
reportsituaonimmediately.

PSI Waste Equipment Services, Inc.
P50 Apartment Compactor SecƟon 2, InstallaƟon4
Site Space Requirements

PSI Waste Equipment Services, Inc.
P50 Apartment Compactor SecƟon 2, InstallaƟon
5
Electrical Requirements
MotorSizeVAC
Phase
NEC
FLA
DualElement
FuseMax
Circuit
BreakerMax
Minimum
WireSize(60degC)
3HP208/1Ph18.7355010
3HP230/1Ph17304510
5HP208/3Ph16.7304510
5HP230/3Ph15.2304012
5HP460/3Ph7.6152012
TheP50controlpanelisratedNEMA3RforindoororoutdooruseULListed.Seethechartbelowfor
branchcircuitinformaon.
Slab Requirements

PSI Waste Equipment Services, Inc.
P50 Apartment Compactor SecƟon 3, OperaƟon6
Changing Containers
Beforeunhookingcontainer,makesureramisinrearposion.PresstheE‐Stopbuonandturnthe
keyswitchtotheOffposion.
Unlatchcontainerasshown.Removecontainerandplaceinstagingarea.
Rollnewcontaineruptocompactor.Latchasshown.
Followinstruconsonthenextpagestooperatecompactor.

PSI Waste Equipment Services, Inc.
P50 Apartment Compactor SecƟon 3, OperaƟon
7
Control Panel
Indice