Pyle PTHM15 Manuale utente

INSTRUCTION INSTRUCTION INSTRUCTION INSTRUCTIONMANUAL MANUAL MANUAL MANUAL
Humidity Humidity Humidity Humidity& &&&Temperature Temperature Temperature TemperatureMeter Meter Meter Meter
Wet Wet Wet WetBulb Bulb Bulb BulbTemperature Temperature Temperature Temperature
DewPoint DewPoint DewPoint DewPointTemperature Temperature Temperature Temperature
MODEL MODEL MODEL MODEL
MODE MAX
MIN

TABLET TABLET TABLET TABLETOF OF OF OFCONTENTS CONTENTS CONTENTS CONTENTS
TITLE TITLE TITLE TITLE
1.INTRODUCTION
2.FEATURES
3.SPECIFICATIONS
4.PANELDESCRIPTION
5.HUMIDITYANDAIRTEMPERATUREMEASUREMENTS
6.BATTERYREPLACEMENT

1. 1. 1. 1.INTRODUCTION INTRODUCTION INTRODUCTION INTRODUCTION
The2in1digitalHumidity&TemperatureMeter&WetBulbTemperatureDewPointtemperature
hasbeendesignedtocombinethefunctionsofHumidityMeter,TemperatureMeter,WetBulb
TemperatureandDewpointtemperature.
ItisanidealHumidity&TemperatureMeterInstrumentwithscoresofpracticalapplicationsfor
Laboratory,industrial,Engineerandprofessional.
TheHumidity&TemperatureMeterisforuseahumidity/semiconductorsensor.Thisoperationsmanual
containsgeneralinformationandspecification.
2. 2. 2. 2.FEATURES FEATURES FEATURES FEATURES
�FastResponseTime
%RH:10S(90%at+25℃stillair)
�HighAccuracy
�
DewpointTemperature(-20℃~80℃/-4℉~176℉)
�WetBulbTemperature(0℃~80℃/32℉~176℉)
�Resolution0.01%RH,0.01℃/0.01℉
�MaxHoldandDataHoldFunction
�
MicroProcessor-basedDesign
�
DualDisplayTemperature&Humidity
�
AutoPowerOff,DisableSleepMode
�
MiniSize
�
Size(H*W*D):175*58*35mm
�Weight:143g

3. 3. 3. 3.SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS
Display: Display: Display: Display:Large4-1/2dualdigitalLCDdisplay.
Sensor Sensor Sensor SensorType: Type: Type: Type:
A
singlechiprelativehumidityandtemperaturemultisensormodulecomprisingacalibrated
digitaloutput.
Response Response Response ResponseTime: Time: Time: Time:%RH:10S(90%at+25℃stillair).
Accuracy Accuracy Accuracy Accuracynote note note note:Accuracyisspecifiedforthefollowingambienttemperaturerange:
64°Fto82°F(18°Cto28°C)
Sampling Sampling Sampling SamplingRate Rate Rate Rate: :::2.5samplespersecond.
Polarity: Polarity: Polarity: Polarity:Automatic,(-)negativepolarityindication.
Over-range: Over-range: Over-range: Over-range:“OL”markindication.
Low Low Low Lowbattery battery battery batteryindication: indication: indication: indication:The“”isdisplayedwhenthebatteryvoltagedropsbelowtheoperatinglevel.
Operating Operating Operating OperatingConditions: Conditions: Conditions: Conditions:32℉to104oF(0
oCto40oC);<80%RHnon-condensing.
Storage Storage Storage StorageConditions Conditions Conditions Conditions: :::14℉to140oF(-10
oCto60oC);<80%RHnon-condensing.
Auto Auto Auto AutoPower Power Power PowerOff Off Off Off: :::Meterautomaticallyshutsdownafterapprox.15minutesofinactivity(SleepMode)
To
overrideAutoPowerOfffunction(Non-SleepMode),firstlypressthehold/backlight
buttonandhold,thenpresspowerbutton,afterthefulldisplayappears,release
bothbuttons.Icon“”willnotshownontheLCD.Theunitwillnotautopoweroffnow.
Power: Power: Power: Power:Onestandard
9V,
NEDA1604or6F22battery.
Dimensions/Wt: Dimensions/Wt: Dimensions/Wt: Dimensions/Wt:175(H)x58(W)x35(D)mm/143g
Humidity/Temperature Humidity/Temperature Humidity/Temperature Humidity/TemperatureMeasurement Measurement Measurement MeasurementRange: Range: Range: Range:
Humidity:0%~100%RH
Temperature:–20℃~80℃(-4℉~176℉)
Resolution:0.01%RH,0.01℃/0.01℉
HumidityAccuracy:
±3%RH(at25℃,20%~80%RH)
±3.5%RH(atotherranges)
Note: Note: Note: Note:Themeasuringrangeisfrom0%to100%,butabove80%andbelow20%thedeviationis
Notspecified.
AirTemperatureAccuracy:
±0.5℃/+0.9℉(at25℃)
±0.8℃/+1.5℉(allotherranges)

4. 4. 4. 4.PANEL PANEL PANEL PANELDESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION
①Humidity Humidity Humidity Humidity/ ///Air Air Air AirTemperature Temperature Temperature TemperatureProbe: Probe: Probe: Probe:(HumiditySensorandSemiconductorSensorinside)
②LCD LCD LCD LCDdisplay: display: display: display:41/2dualdigitsLCDdisplaywithunitsof℃,℉,%RHdewpointwetbulbandlow
battery“BAT”MIN/MAXHOLD,
DATA
HOLDindication.
③MAX/ MAX/ MAX/ MAX/MIN MIN MIN MINButton: Button: Button: Button:
MAX/MIN:PressMAX/MINtoenterMAX,MINRecordingmode(manualrangeonly).Selectthe
properrangebeforeselectingMAXMINtoensurethattheMAX/MINreadingwillnotexceedthe
testingrange.PressoncetoselectMIN.PressagaintoselectMAX.Press Press Press Pressand and and andhold hold hold holdthe the the theButton Button Button Button
for for for forover over over over2 222second second second secondto to to toturn turn turn turnoff off off offMAX, MAX, MAX, MAX,MIN MIN MIN MINRecording. Recording. Recording. Recording.
④℉,,,,℃,,,,dewpoint dewpoint dewpoint dewpoint, ,,,wbt wbt wbt wbtselect select select selectButton: Button: Button: Button:
Press℉,℃,dewpoint,wbtselectButtontoenterselect℉,℃,dewpoint,wbtMeasurement
5
Power Power Power PowerON/OFF ON/OFF ON/OFF ON/OFFButton Button Button Button: :::
TurnthemeterpowerON/OFF
6
Battery Battery Battery BatteryCompartment Compartment Compartment Compartment
MIN
MAX
MODE
1
2
3
5
4
6

5.
5.
5.
5.Humidity
H umidity
Humidity
Humidityand
a nd
and
andair
a ir
air
airTemperature
T emperature
Temperature
TemperatureMeasurements
M easurements
Measurements
Measurements
1.Holdtheprobeintheareatobetested&allowadequatetimeforreadingstostabilize.
2.Press℉,℃,dewpoint,WBTselectButtontoenterselect℉,℃,dewpointWBTMeasurement.
3.ReadtheRelativeHumidityandAirTemperature,dewpointtemperaturewetbulbtemperature.
NOTE:
NOTE:
NOTE:
NOTE:Donotimmersetheprobeinliquid;itisintendedforuseinairon.
Warning:
Warning:
Warning:
Warning:
Don’texposethehumiditysensortodirectsunlight(insolation).
Don’ttouchormanipulatethehumiditysensor.
6.
6.
6.
6.Battery
B attery
Battery
BatteryReplacement
R eplacement
Replacement
Replacement
Ifthesign“”appearsontheLCDdisplay,itindicatesthatthebatteryshouldbereplaced.Openthe
batterycaseandreplacetheexhaustedbatterywithnewbattery.(1x9VbatteryNEDA1604,6F22orequivalent)