REMKO Easy-Control EC1 Manuale utente

Operating and
installation instructions
Read the instructions prior to performing any task!
REMKO remote controls
EC 1
Easy-Control remote control for heat pumps
0242-2019-11 Edition 1, en_GB

Translation of the original
Read these operating instructions carefully before commis-
sioning / using this device!
These instructions are an integral part of the system and must
always be kept near or on the device.
Subject to modifications; No liability accepted for errors or mis-
prints!

Table of contents
1 Safety and usage instructions............................................................................................................. 4
1.1 General safety notes....................................................................................................................... 4
1.2 Identification of notes...................................................................................................................... 4
1.3 Personnel qualifications.................................................................................................................. 4
1.4 Dangers of failure to observe the safety notes................................................................................ 4
1.5 Safety-conscious working............................................................................................................... 4
1.6 Safety notes for the operator........................................................................................................... 5
1.7 Safety notes for installation, maintenance and inspection.............................................................. 5
1.8 Unauthorised modification and changes......................................................................................... 5
1.9 Intended use................................................................................................................................... 5
1.10 Warranty........................................................................................................................................ 5
1.11 Transport and packaging............................................................................................................... 6
1.12 Environmental protection and recycling........................................................................................ 6
2 Technical data........................................................................................................................................ 7
2.1 Unit data.......................................................................................................................................... 7
2.2 Unit dimensions............................................................................................................................... 7
3 Unit description..................................................................................................................................... 8
4Scope of delivery.................................................................................................................................. 8
5 Operation............................................................................................................................................... 9
6 Electrical wiring................................................................................................................................... 15
7 Installation........................................................................................................................................... 17
8 Addressing the EC1............................................................................................................................ 18
9 Index..................................................................................................................................................... 19
3

1 Safety and
usage instructions
1.1 General safety notes
Carefully read the operating manual before com-
missioning the units for the first time. It contains
useful tips and notes such as hazard warnings to
prevent personal injury and material damage.
Failure to follow the directions in this manual not
only presents a danger to people, the environment
and the system itself, but will void any claims for
liability.
Keep this operating manual and the refrigerant
data sheet near to the units.
1.2 Identification of notes
This section provides an overview of all important
safety aspects for proper protection of people and
safe and fault-free operation.The instructions and
safety notes contained within this manual must be
observed in order to prevent accidents, personal
injury and material damage.
Notes attached directly to the units must be
observed in their entirety and be kept in a fully
legible condition.
Safety notes in this manual are indicated by sym-
bols. Safety notes are introduced with signal words
which help to highlight the magnitude of the danger
in question.
DANGER!
Contact with live parts poses an immediate
danger of death due to electric shock. Damage
to the insulation or individual components may
pose a danger of death.
DANGER!
This combination of symbol and signal word
warns of a situation in which there is immediate
danger, which if not avoided may be fatal or
cause serious injury.
WARNING!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may be fatal or cause
serious injury.
CAUTION!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause injury or mate-
rial and environmental damage.
NOTICE!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause material and
environmental damage.
This symbol highlights useful tips and recom-
mendations as well as information for efficient
and fault-free operation.
1.3 Personnel qualifications
Personnel responsible for commissioning, opera-
tion, maintenance, inspection and installation must
be able to demonstrate that they hold a qualifica-
tion which proves their ability to undertake the
work.
1.4 Dangers of failure to observe
the safety notes
Failure to observe the safety notes may pose a risk
to people, the environment and the units. Failure to
observe the safety notes may void any claims for
damages.
In particular, failure to observe the safety notes
may pose the following risks:
nThe failure of important unit functions.
nThe failure of prescribed methods of mainte-
nance and repair.
nDanger to people on account of electrical and
mechanical effects.
1.5 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
REMKO remote controls
4

1.6 Safety notes for the operator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
nThe units and components may only be set up,
installed and maintained by qualified per-
sonnel.
nProtective covers (grille) over moving parts
must not be removed from units that are in
operation.
nDo not operate units or components with
obvious defects or signs of damage.
nContact with certain unit parts or components
may lead to burns or injury.
nThe units and components must not be
exposed to any mechanical load, extreme
levels of humidity or extreme temperature.
nSpaces in which refrigerant can leak sufficient
to load and vent. Otherwise there is danger of
suffocation.
nAll housing parts and device openings, e.g. air
inlets and outlets, must be free from foreign
objects, fluids or gases.
nThe units must be inspected by a service tech-
nician at least once annually. Visual inspec-
tions and cleaning may be performed by the
operator when the units are disconnected from
the mains.
1.7 Safety notes for installation,
maintenance and inspection
nAppropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
nThe setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
nLocal regulations and laws such as Water
Ecology Act must be observed.
nThe power supply should be adapted to the
requirements of the units.
nUnits may only be mounted at the points pro-
vided for this purpose at the factory. The units
may only be secured or mounted on stable
structures, walls or floors.
nMobile units must be set up securely on suit-
able surfaces and in an upright position. Sta-
tionary units must be permanently installed for
operation.
nThe units and components should not be oper-
ated in areas where there is a heightened risk
of damage. Observe the minimum clearances.
nThe units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
nSafety devices must not be altered or
bypassed.
1.8 Unauthorised modification
and changes
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufactured ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
The units are designed depending on the model
and equipment exclusively as a control unit for the
heat pump and the heating system.
Any different or additional use shall be classed as
non-intended use. The manufacturer/supplier
assumes no liability for damages arising from such
use. The user bears the sole risk in such cases.
Intended use also includes working in accordance
with the operating and installation instructions and
complying with the maintenance requirements.
Under no circumstances should the threshold
values specified in the technical data be exceeded.
1.10 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
5

1.11 Transport and packaging
The devices are supplied in a sturdy shipping con-
tainer or inside the heat pump casing. Please
check the equipment immediately upon delivery
and note any damage or missing parts on the
delivery and inform the shipper and your contrac-
tual partner. For later complaints can not be guar-
anteed.
WARNING!
Plastic films and bags etc. are dangerous
toys for children!
Why:
- Leave packaging material are not around.
- Packaging material may not be accessible to
children!
1.12 Environmental protection
and recycling
Disposal of packaging
All products are packed for transport in environ-
mentally friendly materials. Make a valuable contri-
bution to reducing waste and sustaining raw mate-
rials. Only dispose of packaging at approved
collection points.
Disposal of equipment and components
Only recyclable materials are used in the manufac-
ture of the devices and components. Help protect
the environment by ensuring that the devices or
components (for example batteries) are not dis-
posed in household waste, but only in accordance
with local regulations and in an environmentally
safe manner, e.g. using certified firms and recy-
cling specialists or at collection points.
REMKO remote controls
6

2 Technical data
2.1 Unit data
Series Easy-Control EC1
Power supply V/Hz 230 AC, 50
Current load (heating cycle pump) A 3
Probe NTC3950, l0K
Accuracy °C/F ± 0.5/± 1
Set the temperature °C 5-35
Temperature display °C 5-99
Ambient temperature °C 0-45
Humidity (non-condensing) % rel. hum. 5-95
Storage temperature °C 5-45
Current consumption W < 1.5
Timing error % < 1
Housing PC +ABS (fire-resistant)
Suitable flush-mounted socket mm 86 x 86 square or European 60 mm
round box
Wire clips mm2Wire 2 x 1.5 or 1 x 2.5
Enclosure class IP30
Keys Capacitive touch keys
We reserve the right to make technical changes for the purpose of technical advancement.
2.2 Unit dimensions
60 (±2)
86
86
50
14
14
24
50
90
50
90
ABC
Fig. 1: Dimensions (all measurements in mm)
A: Front view
B: Side view
C: Rear view
7

3 Unit description
The Easy-Control remote control EC 1 is a touch
display with an integrated room probe. Operation is
intuitive and self-explanatory due to its clear
arrangement. For example, to enter the desired
room temperature it is only necessary to touch the
“up/down” arrow keys. The anti-freeze protection
function or an absence program can also be set.
Using the room probe it is possible to realise room
temperature-guided regulation in the heating and
cooling mode. The installation is suitable for a
standard flush-mounted socket. Communication
with the heat pump takes place via a Modbus pro-
tocol.
The controller can be used as a wall-mounted
single-room controller.
Fig. 2: Controller as wall-mounted single-room con-
troller
4 Scope of delivery
Description Quantity
Easy-Control EC 1 1
Fastening screws 4
Operating manual 1
REMKO remote controls
8

5 Operation
Remote control display
6
1
2
4
5
8
7
3
9
Fig. 3: Remote control display
The remote control display is realised through the
corresponding symbols on the touch display.
1
Days of the week
2
Setpoint
Is displayed if the room temperature is set.
3
Room temperature
Is displayed if the room temperature is displayed.
4
Automatic mode, time program active
In this case, no time programs of the Smart-Control
Touch are active.
5
Manual mode, no time program
6
Heating/cooling
7
Present or absent
It is possible to enter up to 6 heating times per day.
8
Room set/actual temperature
9
Time
Keys for the remote control settings
10
11
12
13
14
Fig. 4: Keys on the remote control
The remote control is operated using the relevant
keys on the touch display.
10
“On / off” key
Activation of the room temperature regulation. If
the display is switched off, anti-freeze protection
mode is active
11
“M” key
Switching from manual mode to present/absent
mode (time program). The following symbols
appear:
- “Manual” = manual mode
- “Clock” = time program
12
“Clock” key
Using this key it is possible to select and set the
hours, minutes and days of the week (1-7). To con-
firm and continue, press the “clock” key.
13
and the
14
"arrow” keys
To set the room temperature touch the “Up/down”
arrow keys [13 and 14]. The “Set” symbol is dis-
played and the set temperature is displayed. After
the setting is implemented, the display jumps from
“Set” back to the home symbol and the current
room temperature is displayed.
Key lock
To prevent accidental adjustment or access by
unauthorised persons, it is possible to lock the dis-
play. Press the “Clock” key [12] and the “Up arrow”
[13] at the same time for 5 seconds. If the key lock
is activated a padlock symbol appears on the right
next to the time.
9

Setting the time and the day of the week
- Press the “Clock” key [12]. The minute display
flashes.
- Set the minutes with the “Up/down” arrows [13
and 14]. Press the “Clock” key [12] to confirm. The
hour display flashes.
- Set the hours with the “Up/down” arrows [13 and
14]. Press the “Clock” key [12] to confirm. The day
of the week flashes at the top of the display.
- Set the day with the “Up/down” arrows. Monday
1, Tuesday 2, etc. Press the “M” key [11] to con-
firm.
Programming Unit
Press 1 x Minutes
Press 2 x Hours
Press 3 x 1-7 (Monday-Sunday)
Setting the time programs
You have the option of storing six different time
programs in the EC1 per day.
When doing so you can perform programming for
days 1-5 (Monday to Friday), and day 6 (Saturday),
as well as day 7 (Sunday) respectively.
It is not possible to program the individual days
(from day 1 to day 5). (Only block programming).
Programming takes place with the key “ ” and the
arrow keys “ ” and “ ”.
The following times and temperatures are pro-
grammed in the factory:
Weekday switching times (Monday - Friday)
Time Temperature
06:00 - 08:00 hrs 20 °C
08:00 - 17:00 hrs 15 °C
17:00 - 22:00 hrs 20 °C
22:00 - 06:00 hrs 15 °C
Weekend switching times (Saturday - Sunday)
Time Temperature
06:00 - 22:00 hrs 20 °C
22:00 - 06:00 hrs 15 °C
REMKO remote controls
10
Indice
Altri manuali REMKO Telecomando

REMKO
REMKO Smart Control Touch Manuale utente

REMKO
REMKO KFB 3 Manuale utente

REMKO
REMKO KF 22 Manuale utente

REMKO
REMKO KF 23 Manuale utente

REMKO
REMKO HTS Series Manuale utente

REMKO
REMKO KFB 4 Manuale utente

REMKO
REMKO Smart Control Touch Manuale utente

REMKO
REMKO KF 2 Manuale utente

REMKO
REMKO Smart-Com SC-1 Manuale utente

















