Risco gt490x Manuale utente

GG
GGTT
TT44
4499
9900
00XX
XX
CC
CCoo
oonn
nntt
ttrr
rroo
ooll
ll
PP
PPaa
aann
nnee
eell
ll
User Instructions
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 1
Your local installer: www.eaglesecuritysolutions.co.uk

PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 2

Contents
User Information ......................................................... 2
Introduction ................................................................... 3
User Code Types.......................................................... 3
Setting The System ...................................................... 4
Setting The System via a Radio Fob ............................ 5
Setting & Unsetting via Keyswitch ................................ 5
Unsetting The System .................................................. 6
Part Setting The System............................................... 6 - 7
Removing Zones........................................................... 8
Testing The System...................................................... 9
Viewing The Event Log................................................. 10 - 11
Changing The Chime Status......................................... 11 - 12
Programming User Codes ............................................ 13 - 15
Programming Time & Date ........................................... 16
Vo-Comm Introduction.................................................. 17
Vo-Comm Programming ............................................... 17 - 19
Using Vo-Comm ........................................................... 20
Messages from Vo-Comm ............................................ 20
User Initiating Remote Access ..................................... 21
Resetting After An Alarm .............................................. 22 - 23
Setting Engineer Authorisation ..................................... 25
G-Tag Introduction........................................................ 27
Programming G-Tag ..................................................... 27
Using G-Tag ................................................................. 27
Display Status Blanking ................................................ 28
Keypad Tamper ............................................................ 28
Keypad Alert ................................................................. 28
System Tampers........................................................... 28
Mains Failure ................................................................ 29
Setting The System With Mains Fail............................. 29 - 30
Re-setting The Display After A Mains Fail .................... 30
Advanced Code Programming...................................... 31
Using Advanced Codes ................................................ 31
End User Training......................................................... 32
Testing / Servicing Your System................................... 32
System Attributes.......................................................... 35
Service Record ............................................................. 36
User Chart .................................................................... 37
Page 1
GT490X User Manual
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 1

Page 2
User Manual GT490X
User Information
Customer Name:-
Customer Address:-
Control Panel Model GT490X
No of Keypads
Keypad 1 Location
Keypad 2 Location
Keypad 3 Location
Keypad 4 Location
G-Tag 1 Location
G-Tag 2 Location
Keyswitch Location (if fitted) Reserved User Code User No.
Installation Company Name:-
Installation Company Address:-
Installation Company Tel. Fax.
Other Information:-
Note: This section to completed by the installation engineer
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 2

Page 3
GT490X User Manual
Introduction
The GT490X Control Panel is a microprocessor based unit with multiple user and
engineer programmable options. Control of the system is via LCD Remote Keypad
(RKP) giving two rows of 16 character English text. Facility is provided (model
dependant) for Central Station and/or Vo-Comm (message communication) to inform
of system status and alarm events. Vo-Comm messages may be sent to standard land
line telephones or mobile telephones.
Please take time to familiarise yourself with the type of equipment fitted to your
premises as it will prove invaluable whilst using this manual. Your installation company
will give training on the use of the equipment in order to comply with the relevant
standards and will be able to answer specific questions about your system, request for
additional or new staff training should be directed to your installation company.
If the Control Panel is non EN then all displays will be shown and
“ENTER CODE CHECK” will not be displayed.
All information displays will remain until cleared by the User.
User Code Types
Master Level User Code BS / EN2 (default) - 5678
Five Levels of User Codes are available on the GT490X each user code type allows
for different levels of access. In total 15 User codes may be programmed by a Master
Level User Code.
User number 1 will always be a Master Level User but the remaining 14 User Codes
may be programmed (by a Master Code) to the required level of access. These may be
changed at any time via a Master level code. The User Code levels available and the
functions available for the levels are:-
Master Allows Setting, Unsetting, Zone Remove (if programmed by
(User 1 will always engineer), Test System, View Log, Chime On/Off, User
be Master Level) Codes, Set Time/Date, Reset After Alarm (if programmed
by engineer), Unsetting.
Control Allows an output that has been pre-programmed by the
installation company to be operated. May have the attribute
of Can / Cant Unset. May never Set a system
(Refer to Advanced Code Programming for details)
Set Only Only Allows for the setting of the system.
Main User Allows Setting, Part Setting, Zone Remove (if programmed
by engineer), System Test, Unsetting, Reset after Alarm (if
programmed by engineer).
User Allows Setting, Part Setting, Reset after Alarm (if
programmed by engineer), Unsetting.
IMPORTANT USER INFORMATION
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 3

Page 4
GT490XUser Manual
Setting The System
1) With the display showing:-
2) Enter your User code.
(Followed by YES if a Master or Main type code
has been used). The display will show:-
and a continuous exit tone will sound.
Note: Count down in display is dependant on the setting mode
programmed by the Engineer.
3) Exit the premises via the authorised exit route
(the exit tone will change if any detectors are violated during exit).
4) Once the premises are secure listen, (from outside
the protected area) that the exit tone returns to the
continuous tone.
5) Wait until the exit tone finishes before leaving.
Note: If enabled by the engineer, pressing the Quick key during exit time will
shorten exit time to 3 seconds.
Note: G-Tag Proximity Tags may be used for setting and unsetting the
system. Please refer to the Using G-Tag section for instructions.
Note: Depending on the level of your system and the legislation that it is
required to comply with your installation company may have initialised
Display Blanking. When this is used the Status of the system will only
be indicated on the display for ten seconds after it has been Set and for
ten seconds after it has been Unset.
Setting if a Zone has been put on test
If a zone has been put on test, and the system is to be Set /
Part Set / Area Set, the display will show:-
and a warning tone will sound.
If you wish to set the system press NO to continue.
Note: If you are unaware that a zone has been put on test contact
your installation company.
01 JAN 18 : 58 : 01
EXIT Now !
All Zones ON 15
Time will count down
Zone/s On Test
NO to Continue
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 4

Pre Exit Check
At the start of the setting procedure any non exit routes that
are open will show a fault tone. The display will show, for
example:-
If the fault clears within 20 seconds then the exit will begin,
otherwise the display will return to Day (Unset) Mode.
Setting the System via a Radio Fob (Monitored Systems Only)
Setting a monitored system with a radio fob requires interaction with the keypad.
1) When the lock button is pressed on the fob the
display will show:-
2) Press Yes. The system will start to set.
Note: If the No key is pressed or you take longer than 20 seconds the display
will return to the time and date.
Setting & Unsetting the System via a Keyswitch (if fitted)
One of two types of keyswitch(es) may have been fitted to your system.
Normal
To set the system with a normal keyswitch, insert the key and turn to the ON position
then remove the key. Follow the instructions from step 3 (above).
To unset, insert the key and turn to the OFF position.
Biased
To set the system with a biased keyswitch, insert the key and turn it then return the key
to the original position and remove. Follow the instructions from step 3 (above).
To unset, repeat this operation.
Page 5
GT490X User Manual
Zone 8 12hr
Can’t Set ! Check
Press YES to Set
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 5

Page 6
GT490X
User Manual
Unsetting The System
1) Enter the premises via the authorised entry route
(the broken entry tone will sound),
proceed to the keypad.
2) At the keypad enter a valid code, the display
will show:-
3) The system is now unset.
Note: G-Tag Proximity Tags may be used for setting and unsetting the
system. Please refer to the Using G-Tag section for instructions.
Part Setting The System (using Master & Main type codes)
1) With the display showing:-
2) Enter a Master or Main type code, the
display will show for example:-
3) Press 1, 2 or 3 (for Part 1, 2 or 3), the
display will show for example:-
Note: Your installation company will have
informed you what zones are being removed
(omitted) for the Part Set you are using. Refer
to the System Attributes section for what zones
have been programmed as Part Set zones.
01 JAN 18 : 58 : 01
01 JAN 18 : 58 : 01
Do you want to . .
SET the System ?
EXIT!
Part 1 15
Time will count down
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 6

Page 7
GT490X User Manual
4) The exit tone may or may not be heard
depending on the system settings programmed
by the installation company.
5) Exit the premises or retire to an unprotected
part of the system. At the end of the exit time
either the exit sounder will stop, (if the exit tone has
been audible) or a single beep will be emitted (if the
exit tone has been silent).
6) The system is now Part Set, you are free to move
around the zones that have been removed by the
Part Set, but other zones on the system are
active.
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 7

Page 8
GT490X
User Manual
Removing Zones When Setting (Master & Main codes only)
If programmed by the installation company, individual zones may be removed (omitted)
when the system is set, this may only be done by a Master or Main level of code.
1) With the display showing:-
2) Enter a Master or Main level code,
the display will show:-
3) Press NO, the display will show:-
4) Press YES, the display will show:-
5) Enter the zone number you wish to
remove followed by YES. (pressing
NO will 'un-remove' a zone). The
display will show:-
6) Repeat step 5 until you have removed all
the required zones.
7) Press 0 to escape, the display will show:-
8) Press YES, the continuous exit tone will
sound.
9) Exit the premises via the authorised
exit route ( the exit tone will change as detectors
are violated). When the premises are secure
listen that the exit tone returns to the continuous
tone. Wait until the exit tone finishes before leaving.
Note: Zone remove is only effective for the one set.
01 JAN 18 : 58 : 01
Do you want to . .
SET the System ?
Do you want to . .
SET the System ?
Do you want to . .
REMOVE Zones ?
Enter Zone # - - -
then +Yes or -No
Enter Zone # - - -
then + YES or - NO
PR5847 Rev11 490X User Guide.qxd 10/05/2012 11:01 Page 8
Indice
Altri manuali Risco Pannello di controllo

Risco
Risco LightSYS Manuale di istruzioni

Risco
Risco GardTec 350+ Manuale utente

Risco
Risco ProSYS 128 Manuale utente

Risco
Risco RisControl Manuale utente

Risco
Risco GT Plus Manuale di istruzioni

Risco
Risco Gardtec GT480 Manuale utente

Risco
Risco RisControl Manuale utente

Risco
Risco GT 600 Manuale utente

Risco
Risco RisControl Manuale utente

Risco
Risco GT 600 Manuale di programmazione



















