General Safety Summary
Carefully read the following safety precautions to avoid any personal injuries or damages to the instrument and any product connected to it.
To avoid potential
hazards, please use the instrument as specified.
Only the qualified technician can service the instrument.
Avoid fire or personal Injury.
Use proper power line —— Use only the special power line which approved by local state.
Ground the Instrument —— The instrument is grounded through the protective terra conductor of the power line. To avoid electric shock, the ground conductor
must be connected to the earth. Make sure the instrument is grounded correctly before connecting its input or output terminals.
Connect the signal wire correctly —— The potential of the signal wire ground is equal to the earth, so do not connect the signal wire to a high voltage. Do not
touch the exposed contacts or components.
Observe all terminal ratings —— To avoid fire or electric shock, please observe all ratings and sign instruction on the instrument. Before connecting the
instrument, please read the manual carefully to gain more information about the ratings.
Do not operate with suspected failures —— If you suspect that the product is damaged, please let a qualified service personnel check it.
Avoid circuit or wire exposure —— Do not touch exposed contacts or components when the power is on.
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep the surface of the instrument clean and dry.
Safety Terms and Symbols
Terms used on the instrument. Terms may appear on the instrument:
DANGER: Indicates an injury or hazard that may immediately happen.
WARNING: Indicates an injury or hazard that may not immediatelyhappen.
CAUTION: Indicates that a potential damage to the instrument or other
property might occur.
Symbols used on the instrument. Symbols may
appear on the instrument:
Hazardous
Voltage
Warning Protective Chassis
EarthGround Ground
Power
Switch

4
Adjust the Handle
When using the instrument, users can adjust the handle to a position which makes it easier to operate and observe.
Carrying Position
Horizontal Position
Figure 1 Adjust the Handle

5
The Front Panel

6
1.Power Key
This key is used to turn on/off the generator. When the power key is off, it is in the power off state.
2.USB Host
The generator supports U-Disk using FAT format. It’s used to read waveforms or state files from a U-Disk or store the current state of the instrument to the U-Disk.
Users can update the firmware through U-Disk.
3.Touch Screen Display
The generator has a 4.3 inch TFT-LCD touch screen, which displays current function menu, parameter settings, system state, prompts, etc. It is the most important
display and control center of the instrument. For detailed information, please refer to “Touch Screen Display”.
4.Numeric Keyboard
Consists of numbers from 0 to 9, radix points “.” and symbol keys “+/-”, which are used to input parameters.
Note: To enter a negative number, you need to enter a symbol “-” first.
5.Knob
It is used to increase (clockwise) or decrease (anticlockwise) the current numerical value when setting parameters. It is also used to switch characters in the soft
keyboard when inputting a file name. When saving or reading files, rotate the knob to choose a position to save a file or choose a file to be read; press the knob to
open a selected folder or file.
When choosing Waveforms →Page 1/2 →Arb →Arb Type rotate the knob to select a desired built-in or stored waveform.
6.Arrow Keys
When using knob to set parameters, they are used to select the digit to be modified. When using numeric keyboard to set parameters, the left arrow key is used as
a Backspace function. When inputting a file name, they are used to move the position of cursor.

7
Output
Output
Output
Output
7.Channel Control Area
CH1 Control/Output Key
The key on the left is used to turn on/off CH1output.
The nominal output impedance of the BNC connector is 50Ω.
When pressing (the key backlight turns on), the connector outputs waveform according to the current configuration ofCH1.
CH2 Control/Output Key
The key on the right is used to turn on/off CH2output.
The nominal output impedance of the BNC connector is 50Ω.
When pressing (the key backlight turns on), the connector outputs waveform according to the current configuration ofCH2.
8.Channel Select Key
This key is used to switch the current selected channel between CH1 and CH2.
CAUTION:
Overvoltage protection of CH1 and CH2 will take effect once any of the following conditions is met. When overvoltage protection occurs, a message will
be displayed and the output is disabled.
•The absolute value of input voltage is higher than 11V± 0.5V when the amplitude of the generator is higher than or equal to 3.2Vpp or the DC offset is
higher than or equal to |2VDC|.
•The absolute value of input voltage is higher than 4V± 0.5V when the amplitude of the generator is lower than 3.2Vpp or the DC offset is lower than
|2VDC|.
Choose Utility → Page 1/2 → Overvoltage Protection to turn on/off the function.

8
9.Function Keys
----Modulation
This key is used to enable the modulation screen and allow for several types of modulation. It generates AM, DSB-AM, FM, PM, ASK, FSK and
PWM modulated signals.
•It supports “Internal” and “External” modulation sources.
•The corresponding key backlight will turn on when this function is selected.
Sweep ----Sweep
This key is used to generate sweeping frequency signals of Sine, Square, Ramp and Arbitrary.
•It supports “Linear” and “Log” sweep profiles.
•It supports “Internal”, “External” and “Manual” trigger sources.
•The corresponding key backlight will turn on when this function is selected.
----Burst
This key is used to generate burst signals of Sine, Square, Ramp, Noise and Arbitrary.
•It supports “NCycle”, “Gated” and “Infinite” burst modes.
•Noise can only be used to generate gated burst.
•It supports “Internal”, “External” and “Manual” trigger sources.
•The corresponding key backlight will turn on when this function is selected.
----Parameter Setting
Users can switch directly to the parameter setting interface by pressing the key.
•The corresponding key backlight will turn on when this function is selected
Mod
Burst
Parameter

9
Waveforms
Waveforms
----Utility Functions and System Settings
This key is used to set system parameters and check version information.
•Press this key and then press the help soft key to obtain built-in help information about the product.
•The corresponding key backlight will turn on when this function is selected.
----Store and Recall
Through this key, users can store/recall the instrument’s state or arbitrary waveform data edited by users.
•As it supports file management system, users can do general file operations.
•In addition to the built-in nonvolatile memory (C disk), an external U-Disk (D disk) can also be used.
•The corresponding key backlight will turn on when this function is selected.
10.Waveform Option
---- Sine
Provide sine waveform output which ranges from 1μHz to 100MHz.
•The backlight of will turn on when this function is selected.
•“Frequency/Period”, “Amplitude/High level”, “Offset/Low level” and “Phase” of the sine waveform can be adjusted.
---- Square
Provide square waveform output which ranges from 1μHz to 25MHz.
The backlight of will turn on when this function is selected.
•“Frequency/Period”, “Amplitude/High level”, “Offset/Low level”, “Phase” and “Duty” of the square waveform can be adjusted.
Utility
Store/Recall
Waveforms
Waveforms

10
Waveforms
Waveforms
Waveforms
Waveforms
---- Ramp
Provide ramp waveform output which ranges from 1μHz to 1MHz.
•Back light of will turn on when this function is selected.
•“Frequency/Period”, “Amplitude/High level”, “Offset/Low level”, “Phase” and “Symmetry” of the ramp waveform can be adjusted.
---- Pulse
Provide pulse waveform output which ranges from 1μHz to 25MHz.
•Back light of will turn on when this function is selected.
•“Frequency/Period”, “Amplitude/High level”, “Offset/Low level”, “Pulse width/Duty”, “Rise/Fall” and “Delay” of the pulse waveform can be adjusted.
---- Noise
Provide White Gauss Noise output with a bandwidth of 120MHz.
•Back light of will turn on when this function is selected.
•“Stadv” and “”Mean” of the noise signal can be adjusted.
---- Arb
Provide arbitrary waveform output which ranges from 1μHz to 20MHz.
•The backlight of Waveforms will turn on when this function is selected.
•Support two output modes: “DDS” and “True Arb”.
•Built-in include Cardiac, Gauspuls, ExpRise and ExpFall,etc. In addition, the output waveform stored on the U-Disk can be outputted.
•Users can edit arbitrary waveforms through EasyWave and download them to the instrument.
•“Frequency/Period”, “Amplitude/High level”, “Offset/Low level” and “Phase” of the arbitrary waveform can be adjusted.
11.Menu Keys
These keys correspond to the menu displayed above them on the display. Press any key to activate the corresponding menu.
Waveforms
Waveforms
Waveforms