Santint MS3 Manuale utente

MS3 Manual Dispenser & Automatic Shaker
MANUAL
ISO 9001: 2000 CERTIFIED CE CERTIFIED
Please read this manual carefully before operation.

- 1 -
Table of Contents
Chapter Page No.
0.0 Table of Contents 1
1.0 Preface 2
2.0 General Safety Instructions 2
3.0 Configuration 4
4.0 Technical Parameters 5
5.0 Installation 5
6.0 Preparations before Operation 6
7.0 Operation 8
8.0 Dispensing 9
9.0 Maintenance 11
10.0 Replacement 13
11.0 Frequent Issues and Troubleshooting 14
12.0 Circuit Diagram 17
14.0 Explosion Diagram 18
15.0 Nameplate 29

- 2 -
1.0 Preface
Thanks for purchasing the Santint Manual Dispenser!
This user’s manual provides general information on unpacking, installation, usage and
maintenance of the manual dispenser. Any improper use will shorten its longevity.
Read this manual completely and carefully before installation, use and maintenance of
the machine. The manual should be kept in a convenient place for future reference.
For any questions, please do not hesitate to contact our service team.
2.0 General Safety Instructions
1. Warning Labels:
Electricity danger! Please unplug before cleaning and repairing.
(Remark:No need to switch off the power supply before repairing the canisters
assembly.)
Important notice! Please read it carefully.
2. The machine must be placed in a well-ventilated working site. Otherwise an aerator
must be provided.
3. The applicable power cord: refer to the nameplate in the rear. Make sure the power
cord is well grounded to ensure safety.
4. Do not lengthen the power cord as to avoid malfunction or injury.
5. Unplug the MS3 if it is not in use for extended periods of time.
6. When the MS3 needs to be transported to a new site, please secure it by re-inserting
the steel rod through the base and re-install the four feet clamps. The turntable must
be locked by the locking pole so that it is secure. The canisters should be dismantled,
cleaned out and then packed into the cartons.
7. The shaker is compatible with paint cans ranging from 1 liter to 18 liters with a max
weight of 35kg.
8. Do not operate or store in a flammable and explosive environment.
9. The sound level is Decibels:≤75dB(A) measured from 1.6m away from the front,
back, left, right and above of the machine (see Figure 2.1).

- 3 -
10. Surrounding temperature:5℃-50℃; Relative humidity: 15%-90%;
11. Max altitude ≤1000 m.
12. Prior to any maintenance, please unplug the MS3.
13. Use a forklift to gently move the MS3 to the desired location. (see Figure 2.2)
Explanation:
——Decibel Meter
Locations
Testing Data
Front
70-75dB(A)
Back
70-75dB(A)
Left
70-74dB(A)
Right
70-74dB(A)
Above
68-74dB(A)
(Figure 2.1)
(Figure 2.2)

- 4 -
3.0 Configuration
Please See Figure 3.1 as below:
(Figure 3.1)

- 5 -
4.0 Technical Parameters
1.Model:MS3 2.Shape Size:762X800X1443mm
3.Weight:270±5 kg 4.Power Supply:On Name Plate
A.Parameter of Manual Dispenser B.Parameter of Automatic Shaker
Dispensing Speed:20rpm Shaking Time:60/180/300 Seconds(Optional)
Canister's Volume:2.3L Shaking Frequency:680-720rpm
Min Dispensing Quantity:1/384Y (0.077ml)Load Capacity Available:1-20L
Max Dispensing Quantity:2Y (59.14ml)Load Weights Available:1-35kgs
No. of Canisters:12/16/18/20/24/26Canisters Load Can Height Available:50-390mm
Gauge:Optional
5.0 Installation
The shaker and turntable
assembly are fully assembled
before leaving factory. Please
assemble the canisters as
follows:
1. Unpack the crate carefully.
2. Remove the tools from the crate’s base.
3. Remove the steel rod at the base of the MS3 (see Figure 5.1) and the four feet clamps.
Reinstall the steel rods whenever transporting the MS3.
4. To move the MS3, raise the feet by turning them in an anti-clockwise (see Figure 5.2) .
5. Once the MS3 is moved to its final location (must be a flat hard surface), turn the feet in
the clockwise direction until all 4 feet are touching the ground and the MS3 is secure and
stable..
6. Rotate the turntable and install the left canisters one by one (see Figure 5.3 and 5.4)
Once all canisters are installed, the installation is finished.
(Figure 5.1)

- 6 -
6.0 Preparations before Operation
In order to ensure that the shaker works well, please refer to the following preparations
below:
1. Identification on Control Panel (see Figure 6.1 and 6.2)
Figure: “Shaking” mode engaged when T1, T2, or T3 is pressed.
(Figure 6.2)
(Figure 6.1)
(Figure 5.2)
(Figure 5.3)
(Figure 5.4)

- 7 -
Figure: "Shaking"
T1 Button—T1 Seconds Button: once pressed, the clamping plate will automatically
clamp the paint can and shake the paint can for T1 seconds;
T2 Button—T2 Seconds Button: once pressed, the clamping plate will automatically
clamp the paint can and shake the paint can for T2 seconds;
T3 Button—T3 Seconds Button: once pressed, the clamping plate will automatically
clamp the paint can and shake the paint can for T3 seconds.
Default time of T1, T2, and T3 is 60s, 180s, and 300s respectively. The times can be
adjusted to end users values
.
Note: Press any two of T1, T2 and T3 to get the sum of their shaking times.
Button —Stop and Up Button
a) To stop the shaker while in operation, the shaker will stop shaking and clamping
plate will be released.
b) To stop the clamping plate from raising or lowering. Keep pressed and the
clamping plate will continue rising until the button is released.
Button —Emergency Stop Button
a) Once any emergency occurs, press to immediately stop shaking.
b) Release to reinitialize shaker.
Button —Mixing Button
1. Paint can must be sealed well, not deformed, and
the handle be well secured.
2. Ensure that the Mains switch is in “OFF” position before
plugging in an outlet (See Figure 6.3).
3. Ensure that Emergency Stop Button is released.
Preparation before operation
1)The colorant in each canister must be fully mixed (It is not recommended to be
mixed by shaker as too many bubbles may appear that would cause the chromatic
aberration).
2)Remove each canister lid and pour the colorant into the corresponding canister.
Attention: Please stick the specified label on each canister to show different
colorants!

- 8 -
3)Before operation, remove the air out of each pump. Follow the procedures::
●Press and hold the Rough release button and pull the Rough gauge upwards to a
certain height, ie. 1Y.
●Release the Rough release button back to its original position
●Lift up the plunger handle slowly to its full extent and then press it down gently. Do not
move the valve handle during this process.
●Repeat the same procedures 5-6 times;
●Follow the same procedures for the Fine gauge.
7.0 Operation
1) Colorant Mixing
Connect power cord to a wall socket and press the button to initiate
mixing. To stop mixing, repress the button. Stir 3 times every day, at 10
minutes time intervals (If client has special requirements, the daily stir
frequency and time can be altered accordingly).
2) Rotating and Locking of Turntable (See Figure 7.1)
Press the brake handle down to the
horizontal slot.
To lock the turntable:
oRotate the turntable to the
desired position.
oRelease the turntable brake
handle back up to the vertical
slot.
(Figure 6.4)
(Figure 6.5)
(Figure 7.1)

- 9 -
oMove the turntable to the left and right slightly to let the
brake handle return to its original position.
oThe turntable is now locked.
2. Shaking
Switch the mains switch to the “ON” position. The shaker will
automatically initialize and the LCD will display “Initializing”. After
initializing is finished, the LCD will display “Ready”.
Open the shaker door and place the paint can on the center of the
loading platform on a standard can cushion and close the door (see
Figure 7.2).
Select the desired time by pressing the button(s). The clamping
plate will automatically clamp down on the paint can as the LCD will
display “Clamping”. Once the clamping is finished, the shaker
will start shaking and the LCD will display “Shaking” and the
time countdown.
The shaker will stop once the countdown reaches 0 and
the LCD will display “Wait, Please”. The clamping plate will
automatically release the paint can.
Open the door and remove the paint can. When
the LCD displays “Ready”, it is ready for the next shaking.
Please clean off any paint spills
on the clamping plate, loading plate and the two
guide screw shafts every day.
Warning:
A. The shaking without any load or overload is prohibited.
B. During shaking, press Emergency Stop down
immediately in case of any abnormal noises.
C. Press Emergency Stop down immediately in case the
shaker has trouble or is locked up during the initializing
or clamping. Reinitialize the shaker.
D. Unplug before cleaning the shaker.
8.0 Dispensing
The minimum shot of the dispenser is one division on the Fine gauge’s dispensing unit is
marked at the bottom. For example, 2957/384 means the unit is 1/384 US Fl. Oz.
Numbers on the Rough gauge and the Fine gauge have same unit marked at the bottom of
the Rough gauge. For example, if the Rough gauge is marked 2957/48, the number “30”
on the Rough gauge represents the dispensing value of “30x29.57/48ml.”, and number “2”
on the Fine gauge represents the dispensing value of “2x29.57/48ml.”
(Figure 7.2)
Indice
Altri manuali Santint Distributore