Satel SLIM-PIR-PRO Manuale utente

SLIM-PIR-PRO
Digital passive infrared detector
with anti-mask
Firmware version 1.00 slim-pir-pro_en 05/20
SATEL sp. z o.o. •ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu

IMPORTANT
The device should be installed by qualified personnel.
Prior to installation, please read carefully this manual.
Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.
SATEL aims to continually improve the quality of its products, which may result in changes in
their technical specifications and software. Current information about the changes being
introduced is available on our website.
Please visit us at:
http://www.satel.eu
The declaration of conformity may be consulted at www.satel.eu/ce
The following symbols may be used in this manual:
- note,
- caution.

CONTENTS
1. Features ...........................................................................................................................2
2. Description........................................................................................................................2
Active IR anti-mask...........................................................................................................2
Supervision features.........................................................................................................3
LED indicators..................................................................................................................3
Remote configuration mode enable/disable......................................................................3
3. Electronics module ...........................................................................................................3
4. Terminal block ..................................................................................................................5
5. Selecting a mounting location...........................................................................................6
6. Installation ........................................................................................................................7
7. Configuring the detector .................................................................................................11
Starting configuration mode............................................................................................11
Running functions and configuring parameters ..............................................................12
Ending configuration mode.............................................................................................13
8. Start-up and walk test.....................................................................................................13
9. Specifications .................................................................................................................14

2 SLIM-PIR-PRO SATEL
The SLIM-PIR-PRO detector detects movement in the protected area. This manual applies to
the detector with electronics version D.
The detector meets requirements of the EN 50131-2-2 standard for Grade 3.
1. Features
Motion detection with passive infrared sensor (PIR).
Adjustable detection sensitivity.
Digital motion detection algorithm.
Digital temperature compensation.
Option to enable / disable the creep zone protection.
Wide-angle lens designed specially for SLIM detectors.
Option to replace the lens with a curtain or long range one.
Active IR anti-mask, compliant with EN 50131-2-2 requirements for Grade 3.
Ability to configure the detector settings using the OPT-1 keyfob.
Built-in end-of-line resistors (2EOL: 2 x 1.1 k/ 2 x 4.7 k/ 2 x 5.6 k).
LED indicators.
Selectable color of LED indicators light (7 colors available).
Remote LED indicators enable/disable.
Remote configuration mode enable/disable.
Supervision of motion detection system and supply voltage.
Tamper protection against enclosure opening and removal from mounting surface.
Adjustable mounting bracket included.
2. Description
The detector will report alarm when the infrared sensor (PIR) detects motion.
Active IR anti-mask
The active anti-mask feature detects attempts to cover the detector or paint over the lens.
The detector emits infrared radiation and measures the amount of radiation received.
A change in the level of received infrared radiation activates the anti-mask output and
optionally causes the LEDs to flash. The output will remain on / the LEDs will keep flashing
as long as the detector detects masking.
The active anti-mask feature meets the EN 50131-2-2 requirements.
You can enable / disable the anti-mask feature while configuring the detector (see
“Configuring the detector”).
Anti-mask delay
The detector with factory default settings will report masking if it receives a wrong amount of
infrared radiation for 1 second. You can delay the anti-mask activation (see “Configuring the
detector”). The detector will report masking if it is covered for 60 seconds.
If you delay the anti-mask activation, it will not meet the requirements of EN 50131-2-2
for Grade 3.

SATEL SLIM-PIR-PRO 3
Supervision features
In the event of the voltage drop below 9 V (±5%) for more than 2 seconds or the motion
detection system failure, the detector will signal a trouble. The trouble is indicated by the
alarm output activation and the LED indicators coming on. Signaling will continue as long as
the trouble exists.
LED indicators
The LEDs indicate:
warm-up –flashing alternately different colors for about 30 seconds;
alarm –ON for 2 seconds (default color: blue);
masking –flashing when the detector is masked (the same color of lighting as in case of
alarm);
trouble –steady ON for entire duration of the trouble (the same color of lighting as in case
of alarm).
You can change the color. You can select one of seven available colors and enable/disable
the indication of masking (see “Configuring the detector”).
You can enable / disable the LEDs. When disabled, the LEDs will not indicate the states
described above (except the indication of masking which you can enable / disable while
configuring the detector).
Enabling the LEDs by using a jumper
If you put a jumper across the LED pins, the LEDs will be enabled, i.e. they will indicate the
above described events (the LED indicators can’t be enabled/disabled remotely). If you do
not put a jumper across the pins, the LEDs will be disabled, but they can be enabled/disabled
remotely.
Remote LEDs enable/disable
The LED terminal is provided to allow remote LEDs enable/disable. When the terminal is
connected to common ground, the LEDs are enabled. When the terminal is disconnected
from common ground, the LEDs are disabled.
If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal an OC type control panel output programmed e.g. as “Zone test status” or “BI
switch”.
Remote configuration mode enable/disable
The SRVC terminal is provided to allow remote configuration mode enable / disable.
The configuration mode is enabled, when the terminal is connected to the common ground.
If the detector is working in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal the control panel OC type output programmed e.g. as “Service mode status” or
“BI switch”.
3. Electronics module
Do not remove the plastic cover from the circuit board to prevent damage to the
components located on the board.
Do not touch the pyroelectric sensor, so as not to soil it.

4 SLIM-PIR-PRO SATEL
pins for configuration of the detector outputs. Available settings are shown in the figures:
2 –2 x 1.1 kresistors are used,
3 –2 x 4.7 kresistors are used,
4 –2 x 5.6 kresistors are used,
5 –built-in resistors are not used.
If the built-in resistors are used, connect the detector outputs as shown in Fig. 15
or Fig. 17 (mounting on wall) / Fig. 16 or Fig. 18 (mounting on bracket). When the built-in
resistors are not used, connect the detector outputs as shown in Fig. 13 (mounting on
wall) or Fig. 14 (mounting on bracket).
infrared receiver allowing to configure the detector by means of OPT-1 keyfob.
The keyfob is available in SATEL's product range.
MODE button used for configuring the detector (see “Configuring the detector”).
tamper switch activated by cover removal.
buttons used for configuring the detector (see “Configuring the detector”).
LED indicators.
PIR sensor (dual element pyrosensor).
pins to enable/disable the LED indicators.
anti-mask system LEDs.
On the other side of the electronics module is a tamper switch activated by removing the
detector from the wall.

SATEL SLIM-PIR-PRO 5
4. Terminal block
The terminal block is located on the enclosure base (Fig. 6). To get access to the terminals,
you must remove the electronics module (Fig. 8).
AM -anti-mask output (NC relay).
TMP - tamper output (NC relay).
NC - alarm output (NC relay).
COM - common ground.
+12V - power input.
LED - enable/disable the LED indicators.
SRVC - enable/disable the detector configuration mode.

6 SLIM-PIR-PRO SATEL
5. Selecting a mounting location
Do not install the detector outdoors (A).
Install the detector at the recommended height (B). The detector installed at the
recommended height meets requirements of the EN 50131-2-2 standard for Grade 3.
If you choose to install the detector at a height other than the recommended
(permissible installation height: up to 4 m), test the coverage area of the detector.
You may need to install the detector on a bracket and tilt it in order to achieve the
optimal coverage area.
When choosing the installation location, keep in mind that the detector performance will
be the best where the expected direction of the intruder movement will be across the
coverage pattern (C).
Do not install the detector in places where it will be exposed to direct sunlight (D) or light
reflected from other objects (E).
Do not point the detector towards fans (F), air conditioners (G) or heat sources (H).

SATEL SLIM-PIR-PRO 7
6. Installation
Disconnect power before making any electrical connections.
1. Remove the front cover (Fig. 7).
2. Move the electronics module down to unlock it, and then remove it from the enclosure
base (Fig. 8).
3. Make the openings for screws (Fig. 9 or Fig. 10) and cable (Fig. 11) in the enclosure
base. If the detector is to be mounted directly on the wall, make a screw hole in the
tamper protection element. The place in which to make the opening is indicated with the
sign in Fig. 9.
4. Pass the cable through the prepared opening. If the detector is to be mounted on the
bracket, run the cable and the wires of tamper switch located in the bracket as shown in
Fig. 10.
5. Secure the enclosure base to the wall (Fig. 9) or a bracket fastened with screws to the
wall or ceiling (Fig. 10). The wall plugs (anchors) delivered with the device are intended
for concrete, brick, etc. For other types of surface (drywall, styrofoam), use the
appropriately selected wall plugs.

8 SLIM-PIR-PRO SATEL
6. Connect the wires to the corresponding terminals. If the detector is mounted on the
bracket, connect the tamper switch in series with the detector tamper output. The way of
connecting the tamper switch is shown in Fig. 14 (NC configuration), Fig. 16 (2EOL
configuration) and Fig. 18 (3EOL configuration).
7. Place the electronics module in the enclosure base and then move it up to lock it.
8. Configure the detector (see “Configuring the detector”).
9. If the detector is to protect the creep zone, the knob located on the inner side of the
enclosure cover is to be set in position shown in Fig. 12-A. If the detector is NOT to
protect the creep zone, set the knob to the position shown in Fig. 12-B.
10.Replace the cover.
Indice
Altri manuali Satel Sensore di sicurezza

Satel
Satel VD-1 Manuale utente

Satel
Satel SLIM-DUAL-PRO Manuale utente

Satel
Satel IVORY Manuale utente

Satel
Satel AQUA LUNA Manuale utente

Satel
Satel SILVER Manuale utente

Satel
Satel AQUA Manuale utente

Satel
Satel PDB-100 Manuale utente

Satel
Satel ARD-100 Manuale utente

Satel
Satel APD-100 Manuale utente

Satel
Satel AGATE Manuale utente

Satel
Satel AQUA S Manuale utente

Satel
Satel XD-2L Manuale utente

Satel
Satel COBALT Manuale utente

Satel
Satel micra MPD-310 Pet Manuale utente

Satel
Satel INDIGO TESTER Manuale utente

Satel
Satel OPAL Pro Manuale utente

Satel
Satel TESTER INDIGO Manuale utente

Satel
Satel AFD-100 Manuale utente

Satel
Satel APMD-150 Manuale utente

Satel
Satel INDIGO Manuale utente