5
TECHNICAL DATA AND DIMENSIONS
The stove can take logs up to 50 cm (vertically placed).
Intermittent operation in this context means normal use of
a wood-burning stove. In other words, you should let the fire
die down until only the embers are left before refueling.
This stove is produced in accordance with type approval for
the product, which also covers the product’s Assembly and
Instruction Manual.
The Declaration of Performance (DoP) is available from
www.scan-stoves.com
Test in compliance with EN 13240
CO Emission at 13% O20,07 %
CO Emission at 13% O2929 mg/Nm3
Dust @ 13% O227 mg/Nm3
Nox@ 13% O296 mg/Nm3
Efficiency 84 %
Energy efficiency index 112
Energy efficiency class A+
Nominel output 11,5 kW
Chimney temperature EN 13240 168 °C
Temperature in flue conn. piece 202 °C
Amount of smoke 12,9 g/sec
Sub-pressure EN 13240 12,7 Pa
Recommended sub-pressure in
connecting piece 18 Pa
Required combustion air supply 38 m3/h
Fuel Wood
Fuel consumption 3,2 kg/h
Amount of fuel 2,55 kg
Amount of fuel, max. 4,8 kg
Surface treatment Senotherm
Max. wood length 40 cm*
Weight Scan 87 approx. 273 kg
Weight Scan 87 wall-hung approx. 250 kg
Connecting piece internal diameter 194 mm
Connecting piece external diameter 198 mm
Fresh air connection piece external diameter 125 mm
Approval type Intermittent fuelling**
Materials
Stainless steel plate
Cast iron
Ceramic stone/vermiculite
Glass
*
**