• Lock Control Jumper: To congure the electronic lock safety type; set the jumper in 1-2 position for Power-
to-Unlock type(pulse activated electronic lock), set the jumper in 2-3 position for the Power-Off-to-Unlock
type(electromagnetic lock). Remove the jumper if using external power supply for the lock.(the power+ will be
connected to the PL on the Main Connect Port)
• Camera Code DIP: To set the code for the door camera, total 4 cameras can be connected in the system; See
chapter 18 Multiple Door Camera Connection -- Note 3.
• Main Connect Port: To connect the bus line and the electronic locks.
• BUS: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power positive(power +).
• S1+, S2+: Lock power(+) output, to connect 2 electronic locks.
• S-: Lock power(-) output, connect to the power(-) input of electronic locks(only when using the camera to power
the locks, if using the external power supply for the locks, the S- will not be connected)
2. Electronic Lock Connections
The standard inner power lock connection, use the Camera power to supply the lock, no need for external power
supply. In this way, the Lock Control Jumper and Unlock Mode in the monitor need to be set: for Power-to-Unlock
type electronic lock, set to position 1-2 and Unlock Mode 0; for Power-Off-to-Unlock type electromagnetic lock, set to
position 2-3 and Unlock Mode 1(see chapter 16 Unlock Mode Setting).
-
+
Electronic lock
-
+
ElectronMagnetic lock
-2-