schroff 7 U Manuale utente

VME System Subracks 7 U / 8 U
User Manual
Product Numbers:
20836-716
20836-719
20836-815
Revision: R1.0, September 22, 2006
Doc-No: 63972-147

Impressum:
Schroff GmbH
D-75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and
checked - supported by certified Quality Management System
to EN ISO 9001/2000
The company cannot accept any liability for errors or misprints.
The company reserves the right to amendments of technical
specifications due to further development and improvement of
products.
Copyright © 2006
All rights and technical modifications reserved.
Rev. Date updated Change
R1.0 September 22, 2006 Initial Release

VME System Subracks 7 U / 8 U
20836-716/-719/-815
www.schroff.biz I R1.0, September 22, 2006
Table of Contents
1 Safety................................................................................................................. 1
1.1 Indended Application........................................................................................... 1
1.2 Safety Instructions............................................................................................... 2
1.3 Safety Symbols used in this document................................................................ 2
1.4 General Safety Precautions................................................................................. 2
1.5 References and Architecture Specifications........................................................ 3
2 Product Definition............................................................................................. 4
2.1 Mechanical Overview........................................................................................... 5
2.2 Subrack................................................................................................................ 6
2.3 VME Backplane................................................................................................... 6
2.4 Power Supply....................................................................................................... 7
2.4.1 Grounding.............................................................................................. 7
2.5 Thermals............................................................................................................ 10
2.6 Fan Control Module (FCM)................................................................................ 11
2.7 Chassis Monitoring Module (CMM) -optional- ................................................... 12
2.8 Display Module.................................................................................................. 13
3 Installation....................................................................................................... 14
3.1 Unpacking.......................................................................................................... 14
3.1.1 Ensuring Proper Airflow....................................................................... 14
3.2 Rack-Mounting................................................................................................... 15
3.3 Assembly of additional Backplanes................................................................... 16
3.4 Basic Functional Check..................................................................................... 17
4 Service............................................................................................................. 18
4.1 Technical support and Return for Service Assistance....................................... 18
4.2 Declaration of Conformity.................................................................................. 18
4.3 Scope of delivery............................................................................................... 19
4.4 Accessories ....................................................................................................... 19
4.5 Spare Parts........................................................................................................ 19
5 Technical Data ................................................................................................ 20
6 Dimensions ..................................................................................................... 21

VME System Subracks 7 U / 8 U
20836-716/-719/-815
www.schroff.biz II R1.0, September 22, 2006

VME System Subracks 7 U / 8 U Safety
20836-716/-719/-815
www.schroff.biz 1 R1.0, September 22, 2006
1 Safety
1.1 Indended Application
The VME system subrack, described in this manual, is indended as a platform
for a microcomputer system based on the VME bus system (VITA 1-1994).
The VME system subracks are designed for protection class IP 20 and can be
used only in the resp. environments.
For higher protection requirements, a.e. IP 54/55 you must install the system
subrack in a protective case.
VMEsystemsubracksare notend-products,sothereis novalidapprovalfor this
unit. In order to enable stand-alone functionality,additional elements are
required. An operational system is achieved only by way of appropiate VME
boards.
The completion and final testing of the units have been carried out, or at least
supervised, by qualified technicians. These instructions are directed exclusively
to these qualified technicians i.e.engineers, trained and qualified electricians
etc.
Make sure that:
• the assembled unit complies with the safety regulations currently applicable
in the country it is going to be used.
• the overall unit complies with all other regulations and specifications at the
place and country of use, e.g. interference limits, approval by the telecom-
munications authorities.

VME System Subracks 7 U / 8 U Safety
20836-716/-719/-815
www.schroff.biz 2 R1.0, September 22, 2006
1.2 Safety Instructions
The intended audience of this User’s Manual is system integrators and
hardware/software engineers.
1.3 Safety Symbols used in this document
1.4 General Safety Precautions
• Service personnel must know the necessary electrical safety, wiring and
connection practices for installing this equipment in a telecommunication
environment.
• Install this equipment only in compliance with local and national electrical
codes.
Hazardous voltage!
This is the electrical hazard symbol. It indicates that there are dangerous
voltages inside the Shelf.
Caution!
This is the user caution symbol. It indicates a condition where damage of the
equipment or injury of the service personnel could occur. To reduce the risk of
damage or injury, follow all steps or procedures as instructed.
Danger of electrostatic discharge!
TheShelfcontainsstaticsensitivedevices.Topreventstaticdamageyoumust
wear an ESD wrist strap.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is
intended to be accessed, to be installed and maintained by qualified and
trained service personnel only.
This equipment is designed in accordance with protection class 1!
It must therefore be operated only with protective GND/earth connection!

VME System Subracks 7 U / 8 U Safety
20836-716/-719/-815
www.schroff.biz 3 R1.0, September 22, 2006
1.5 References and Architecture Specifications
• User Manual VME Backplanes
Order no.: 73972-103
• Short Form User Manual VME J1/J2 Monolithic Backplanes
Order no.: 73972-128
• User Manual Fan Control Module (FCM)
Order no.: 73972-083
For more information see the catalogue „Electronic Packaging“ and at
www.schroff.biz

VME System Subracks 7 U / 8 U Product Definition
20836-716/-719/-815
www.schroff.biz 4 R1.0, September 22, 2006
2 Product Definition
The Schroff VME subrack system consists of:
• A shielded 19“ subrack with front assembly area for
6 U front boards according to VME Standard (VITA 1-1994)
• A VME (VITA 1-1994) Backplane
• An open frame power supply with wide range input
• Speed controlled fans for cooling the boards
• Fan Control Module (FCM) for fan monitoring/controlling
• Display module
• Mains/line switch
• Rear assembly area for three 6 U, 4 HP Rear Transition Modules
The fans and the power supply are assembled on the bottom-hinged rear panel.
System differences:
The subracks 20836-716/-719 are identical in their construction. The only
difference is the depth (355 mm/475 mm).
The subrack 20836-815 is identical to 20836-716 with the following exceptions:
The 7 U system has a 0,5 U bottom plenum and a 0,5 U upper plenum. The 8 U
system has a 1 U bottom plenum and a 1 U upper plenum for more efficient
airflow and cooling.
20836-717 20836-815
Power supply 5 V / 60 A 5 V / 120 A
Fans 3 x 170 m³/h (100 cfm) 3 x 237 m³/h (140 cfm)
Backplane 12-Slot 21-Slot
Height 7 U 8 U
Variations
The Schroff assembly service can customize your subrack system with:
• Different Backplane configurations
• Drive mounting cassettes
• Special power supplies
• A Chassis Monitoring Module (CMM)
More information in the catalogue or at www.schroff.biz

VME System Subracks 7 U / 8 U Product Definition
20836-716/-719/-815
www.schroff.biz 5 R1.0, September 22, 2006
2.1 Mechanical Overview
Figure 1: Mechanical Overview (Shown at 7 U System)
10006813
1 Front card cage with guide rails 7 Fan Control Module (FCM)
2 Front panel 6 U / 36 HP
(Only 7 U system) 8 Display module
3 Space for Rear Transition Modules 9 Power supply
4 Bottom-hinged rear panel 10 AC terminal with line filter
5 VME Backplane 11 Mains/line switch
6 Axial fans

VME System Subracks 7 U / 8 U Product Definition
20836-716/-719/-815
www.schroff.biz 6 R1.0, September 22, 2006
2.2 Subrack
The 7 U / 8 U 19“ system based on the Schroff europacPro System with EMC
shielding.Thefrontcardcageprovides spacefortheinstallationof12 or21VME
Boards (6 U, 4 HP, 160 mm deep).
The lower guide rails are fitted with ESD clips.
The horizontal assembly area allows the installation of 3 Rear Transition
Modules (6 U, 4 HP). The depth depends on the system. The subrack system
20836-716 and 20836-815 allows Rear Transition Modules with a depth of 120
mm, the subrack system 20836-719 allows up to 240 mm depth.
2.3 VME Backplane
The 6 U Backplane (J1/J2 Monolithic) is compliant to:
• VITA 1-1994
• VITA 38 Systemmanagement for VME
The subrack systems 20836-716/-719 have a 12-Slot Backplane as standard,
the subrack system 20836-815 has 21-Slot Backplane. You can customize your
system with different Backplanes.
For more information see the Backplane’s User Manual, Order No.: 73972-103/
-128, in the catalogue and at www.schroff.biz
The front card cage at the 7 U system is upgradeable to 21 slots.
1 Slot = 4 HP = 20,32 mm
Questo manuale è adatto per i seguenti modelli
4
Indice