Sigmann DELTA SD161BTex Manuale utente

Sigmann DELTA GmbH Tel. 06268-92899-73 Handelsregister
Hauptstraße 53 Fax 06268-92899-74 Mannheim HRB 703603
D-74928 Hüffenhardt info@sigmann-delta.de Geschäftsführer
UstIDNr: DE257944309 http://www.sigmann-delta.de Joachim Kraus
Date: 11.02.2020
Operating Instructions
Bluetooth Handheld Scanner
SD161BTex SD261BTex 3rd
Type SD.118.0000.0X Type SD.11B.000.00

SD160BTex_BA_en_008.docx

SD160BTex_BA_en_008.docx
Table of contents
1 Product range Bluetooth Scanner Zone 1 3
2 Scanner overview 4
3 Compatible Scanner and Base station overview 5
4 Important Notes on the Operating Instructions 6
4.1. Safety Information ........................................................................................... 6
4.2 Notes on the Operating Instructions ........................................................................................... 7
4.3 General Notes of Caution ........................................................................................... 8
5 Product Information SD161BTex 10
5.1 Explosion Protection .................................................................................. 10
5.2 Technical Data Handheld Scanner .................................................................................. 10
5.3 Technical Data Base Charging Station SDX61BTex Basis .............................................. 11
5.4 Technical Data Base Charging Station SDX61BTex Basis 3rd .............................................. 12
5.5 Type Numbers –1D Scanner SD161BTex .................................................................................. 13
5.6 Serial Number .................................................................................. 13
5.7 Application ................................................................................... 13
6 System Assembly - 1D Scanner SD161BTex 14
6.1 System assembly 1 –Explosion-protected base charging station ................................ 14
6.2 System assembly 2 –Non-explosion-protected base charging station ................................ 15
7 Product Information SD261BTex 3rd 16
7.1 Explosion Protection .............................................. 16
7.2 Technical Data Handheld Scanner .............................................. 16
7.3 Technical Data Base Charging Station SDX61BTex Basis .............................................. 17
7.4 Technical Data Base Charging Station SDX61BTex Basis 3rd .............................................. 18
7.5 Type Numbers –2D Scanner SD261BTex 3rd .............................................. 19
7.6 Serial Number .............................................. 19
7.7 Application .............................................. 19

SD160BTex_BA_en_008.docx
8 System Assembly - 2D Scanner SD261BTex 3rd 20
8.1 System assembly 1 –Explosion-protected base charging station ................................ 21
8.2 System assembly 2 –Non-explosion-protected base charging station ................................ 21
9 Cable range in system assembly 22
9.1 Cable range in system assembly 1 .......................................... 22
9.2 Cable range in system assembly 2 .......................................... 22
10 Step-by-step guide on installation and operation 23
10.1 Preparation SD161BTex / SD261BTex 3rd for System assembly 1 & 2 ................................... 23
10.2 Using base charging station for system 1 ................................... 24
10.3 Using base charging station for system 2 ................................... 25
10.4 Pin assignment power supply SDVM125ex RS232 ................................... 26
10.5 Pin assignment power supply SDVM125ex USB ................................... 28
11 Attachment 30
11.1 EG-Type Examination Certificate SD161BTex and SDX61BTex base charging station .......... 30
11.2 Certificate of Conformity SD161BTex and SDX61BTex base charging station .......... 35
11.3 EG-Type Examination Certificate SDVM125ex .......... 41
11.4 Certificate of Conformity SDVM125ex .......... 45
12 Contact 51

SD160BTex_BA_en_008.docx 3
1Product range Bluetooth scanner Zone 1

4 SD160BTex_BA_en_008.docx
2 Scanner overview
Wired
Bluetooth
1D
PDF
2D
SD160ex
SD160exPDF
SD260ex 3rd
SD161BTex
SD161BTex PDF
SD261BTex 3rd

5 SD160BTex_BA_en_008.docx
Scanner
Typenumber
Scanner
Typenumber
Base station/
Charging station
Description
Connection
cable USB
Connection
cable RS232
Power supply
SDVM125ex
SD161BTex
SD.118.0000.0X
SD.119.0000.00 /
SD.11C.0000.00
Base station for hazardous area
SD.Z10.0011.0X
SD.Z10.0010.0X
SD.Z10.0007.0X
with USB-Connection:
SD.211.X111.00
with RS232-Connection:
SD.211.X011.00
SD.211.X001.00
SD261BTex 3rd
SD.11B.0000.0X
SD.119.0000.00 /
SD.11C.0000.00
SD161BTex
SD.118.0000.0X
SD.Z10.0035.00
Base station for non hazardous area
SD.Z10.0013.0X
SD.Z10.0012.0X
With USB-Connection:
PC USB-Interface
Wtih RS232-Connection:
only 5V-non hazardous
power supply
SD.Z10.0016.00
SD261BTex 3rd
SD.11B.0000.0X
SD.Z10.0035.00
SD161BTex
SD.118.0000.0X
SD.Z10.0034.00
Charging station for non hazardous
area without Bluetooth function
SD.Z10.0013.0X
SD.Z10.0012.0X
With USB-Connection:
PC USB-Interface
With RS232-Connection:
only 5V-non hazardous
power supply
SD.Z10.0016.00
SD261BTex 3rd
SD.11B.0000.0X
SD.Z10.0034.00
3Compatible Scanner and Base station overview

SD160BTex_BA_en_008.docx 6
4Important notes on the Operating Instructions
4.1 Safety information
Warnings are highlighted by a special symbol and a different font colour:
Danger
Non-compliance may result in life-threatening situations.
This warning must be heeded.
Warning
This type of warning concerns dangerous situations that may result in minor injuries.
Info
Important and helpful notes and information.

7 SD160BTex_BA_en_008.docx
4.2 Notes on the Operating Instructions
Before starting up the equipment please read the Manual thoroughly.
The Operating Instructions contain important information on functionality as well as safety rules. If these
are not heeded, normal operations within hazardous areas cannot be guaranteed.
The notes contained in this manual are important for starting up and operating the product.
These instructions may be updated at any time. Sigmann DELTA GmbH reserves the right to make changes to
this document.
Before using the product, users must ensure that they have the most up-to-date version of the operating instruc-
tions.
To be sure this is the case, please check Sigmann DELTA's website at www.Sigmann-DELTA.de or contact one
of the company's staff.
The drawings contained in these operating instructions are for illustration purposes only and may differ somewhat
from the actual design.
No changes may be made to the device that were not intended or approved
by Sigmann DELTA.
If the handheld scanner is not used properly, the operating permission for hazardous areas may lapse for the
device in question.
Non-adherence to the instructions will void any warranty.
For the full commission of the SD161BTex / SD261BTex 3rd handheld scanner the programming information
contained in the manual issued by SICK AG (www.SICK.com) are also required.

SD160BTex_BA_en_008.docx 8
4.3 General notes of caution
Caution / Notes
The devices may only be operated when fully assembled.
In hazardous areas the devices must not be wiped or cleaned with a dry cloth.
The device must be switched off immediately if it is likely that as a consequence
of damaging impact or general peculiarities the device can no longer be safely
operated. (e.g. ingress of water or other fluids, temperatures outside of the
specified range,...)
General statutory requirements or health and safety rules and accident preven-
tion guidelines and environmental laws must be adhered to (e.g. the German
Occupational Health and Safety regulation).
Users must not open the device.
Users must not make any changes to the device. Components may not be ex-
changed or replaced. If non-specified components are used, explosion protec-
tion is no longer guaranteed.
Ensure safe handling with firm footing and sufficient room for movement.
If the enclosure is in any way damaged the device must be removed from the
hazardous area immediately.
In accordance with IEC 60079-19 and IEC 60079-17, operators of electrical
installation in hazardous areas are obliged to have them serviced by qualified
electricians.
Do not insert any sharp objects into the enclosure or any other openings of the
handheld barcode scanner. Any openings at the device may not be covered or
blocked.
The device and any accessories must be properly disposed of, i.e. as legally
specified, for example by a certified company.
Notes on installation
Electrical plants are subject to certain regulations concerning installation and
operation (e.g. RL 99/92/EG, RL 2014/34/EU, or the national rules such as
IEC 60079-14 and VDE 0100).
In the hazardous area it is the operator's responsibility to carry out any repair
and maintenance in compliance with applicable rules.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Sigmann DELTA Scanner