1. General Method of Operation........................................................................ 2
2. System Requirements ................................................................................... 2
3. Installing the PalmLDB .................................................................................. 3
4. Starting Actions ............................................................................................. 4
5. Exporting the Locking Plan to the Palm ...................................................... 7
6. Editing Lockings ............................................................................................ 9
7. Reimporting Data From the Palm to the PC................................................15
8. Checking and Repairing the Database........................................................16

Operating Instructions for the Palm LDB Version 1.40
2 Version: June 2004
1. General Method of Operation
With the Palm Organizer (versions: Palm m5xx, Tungsten W and Tungsten
T3) and the PalmCD2 programming device, you can very conveniently and
easily program and read out your System 3060 digital lockings.
If you use a Palm Tungsten W, you must make sure that you deactivate
the mobile radio telephone function when you operate it together with the
PalmCD2, because otherwise the radio range to the digital locking can be
restricted.
1.1 Programming Lockings
Create the locking plan with the help of the LDB locking plan software. We
recommend that you use a PC to program the components (lockings,
transponders) the first time. Subsequent changes to the authorizations are
made in the locking plan software and then transmitted to the Palm (m5xx,
Tungsten W and Tungsten T3). After that, you can program the lockings with
the PalmCD2 and also make changes in the locking plan (authorize or block
transponders). When you have completed the programming, transmit the
updated data to the locking plan software on the PC.
1.2 Reading out Lockings
You can use the PalmCD2 in combination with the Palm (m5xx, Tungsten W
and Tungsten T3) to read out access lists and transponder lists on the spot.
You can also combine the PalmCD1 with the Palm Vx.
1.3 Opening the Door
An emergency opening with the help of the password is also possible.
2. System Requirements
The PalmLDB software is compatible with all Palm Organizers listed
above that have the PalmOS operating system, from version 3.5 to 5.2.1.
Make sure that you always use the latest software versions for the LDB
locking plan software and the PalmLDB. You can obtain more information
on this subject from your dealer or directly from SimonsVoss.

Operating Instructions for the Palm LDB Version 1.40
3 Version: June 2004
3. Installing the PalmLDB
Before you install the PalmLDB, you must install the Palm Organizer Software
and carry out a HotSync.
If an older PalmLDB version is installed on the Palm, you must delete it
first.
Insert the SimonsVoss CD. In the Windows task bar, click Start Programs
Palm Desktop Palm Quick Install, and then Add. Select the CD-ROM
drive and click Software PalmLDB English PalmLDB_deDe.
☺
deDe indicates that this is the German version of the PalmLDB (the file
has a different and appropriate abbreviation for each country).
Now click Done and carry out a HotSync procedure. Then the icon for starting
the PalmLDB appears on the Palm interface under the category SimonsVoss.
3.1 Starting the PalmLDB
Touch the key symbol with the Palm stylus to start the PalmLDB. If you have
not yet exported a locking plan to the Palm, you will see the message
Database not complete. Furthermore, the Edit Lockings button will not be
visible in the main menu.
3.2 Read the Software Version

Operating Instructions for the Palm LDB Version 1.40
4 Version: June 2004
Do this by touching PalmLDB PalmLDB-Info in the menu bar. If an older
software version (< PalmLDB1.40) is installed, please contact your dealer or
SimonsVoss directly.
Make sure that the LDB that you are using matches the respective
PalmLDB. If an older software version (< LDB1.40) is installed, please
contact your dealer or SimonsVoss directly.
You can also operate the Palm LDB1.40 in combination with the WaveNet
LDB (1.41).
4. Starting Actions
Now you can carry out the following actions:
Edit lockings
Program and read out lockings
Open the door
Carry out an emergency opening with the help of the password
ConfigDevice
Reset and test the programming device
Exit
Leave the program
Before you can program and read out the access list and transponder lists,
you must first load the locking plan on to the Palm (see the section "Exporting
the Locking Plan to the Palm").
☺There is a test system on the SimonsVoss CD. If you would like to
familiarize yourself with this locking system, you must use the Install Tool
to install all six files (PDB format). The test system's file password is test.

Operating Instructions for the Palm LDB Version 1.40
5 Version: June 2004
4.1 Carry out Emergency Opening
Touch the Open door button. Then enter the locking system password (for
LSM: the user password) on the keyboard shown in the display. Pay attention
to upper and lower case letters – the password is case-sensitive. Then touch
OK.
4.2 Testing the PalmCD2
Touch the ConfigDevice button. Then place the Palm (m5xx, Tungsten W and
Tungsten T3) on the PalmCD2.
Touch Test to check the PalmCD2 programming device. If it does not
respond, you can reset it with the button with that name. Then check your
programming device again. The PalmCD2 should report software version 9.3
or later.
PalmCD2: If the PalmCD2 does not respond, you should check the battery
status. If necessary, remove the PalmCD2 from the Palm briefly
and then put it on again.

Operating Instructions for the Palm LDB Version 1.40
6 Version: June 2004
4.3 Reading out an Unknown Locking
Touch Edit lockings and then Read.
You will see the following information:
•ID numbers of the locking system and locking
•Battery status of the locking
•Software version of the locking
With the Status and Configuration buttons, you can obtain additional
information on the locking.

Operating Instructions for the Palm LDB Version 1.40
7 Version: June 2004
5. Exporting the Locking Plan to the Palm
Open your locking plan on the PC and
make any changes that are necessary.
Then authorize the locking plan and
transponder programming. Select File
Export Palm databases.
Select All transponders or only
particular transponders. If you
would like to have the
transponder descriptions included
in the display when you read out
the access list or transponder list,
you should always activate All
transponders. Otherwise, the
read-out display shows only the
ID numbers of the transponders, not their descriptions. Next, select the locking
system and lockings that you want to edit with the Palm.
You can select lockings in one of
the following ways:
1. All lockings
2. Lockings that need to be
programmed
3. Only particular lockings
Transmit complete list of
authorizations means that the
complete locking plan will be
exported. This is particularly
important if you want to use the
Palm to make short-term
changes to the authorizations. If
you do not select this option,
only the locking plan changes will be transmitted. Confirm with OK.

Operating Instructions for the Palm LDB Version 1.40
8 Version: June 2004
Now indicate the Palm user for whom the locking plan is to be exported and
whether you want to end
the HotSync manager
automatically after
transmission. The last
setting is important if you
subsequently want to
work with the
ConfigDevice on the
same serial interface. If
you want to synchronize
the time of day on the PC
with that on the Palm,
activate Set time on the
Palm and confirm with
OK. We recommend that
you always set the time.
Make sure that the time of day and date in the Palm agree with the real
time and date. It may be that the Palm does not automatically switch over
to daylight saving time or standard time.
Carry out a HotSync procedure. The locking plan will now be transmitted to
your Palm.
You must end the PalmLDB on the Palm to export data from the LDB or
LSM to the Palm or to import data from the Palm to the LDB or LSM.
To set the baud rate, proceed as described in the following. In the task
bar, click the symbol and then Configure... If you are using the
PalmCD2, you should normally set the speed to "as fast as possible" in the
Local tab. If there are problems during the synchronization, we
recommend that you reduce the baud rate.
After you export the locking plan to the Palm, you should not make any
further changes in the locking plan software LDB until the import, because
otherwise there could be conflicts, or so-called inconsistencies.

Operating Instructions for the Palm LDB Version 1.40
9 Version: June 2004
6. Edit Lockings
In the PalmLDB, touch Edit lockings and then
Enter. Enter the file password on the
keyboard shown in the display. Pay attention
to upper and lower case letters – the
password is case-sensitive.
Then touch OK. If you touch the down arrow,
a list of available locking systems appears;
you can make your selection from this list.
The Palm can always edit only one
database exported from the LDB, but it is certainly possible that this
database contains more than one locking system.
Now you can carry out the actions described in the following sections.
6.1 Reading out Lockings
Place the PalmCD2, with the Palm Organizer
on it, close to the digital locking and touch
Read.If the locking that you are reading
needs to be programmed, the Program button
will be framed in a thick line.
The display contains information on the
locking's properties. You can also display the
access list or transponder list. Touch the
appropriate buttons.
Reading out the lists can take some time. You can shorten this time by
displaying only the transponder ID numbers, not the descriptions. You can
choose this option in the PalmLDB in Administer lockings under Options
Configuration. Do this by selecting the "Administer locking systems" field.

Operating Instructions for the Palm LDB Version 1.40
10 Version: June 2004
If you do not want to display the transponder
names, deactivate the control box by touching
it.
To determine whether the Palm is
communicating with the corresponding locking
via the PalmCD2, you can select the "Acoustic
acknowledges" control box. This provides an
acoustic signal indicating ongoing radio
communication throughout the entire
programming process.
If you are programming an SREL.ADV in combination with one or more
Smart Output modules (expansion modules), the time required for both
the programming and the processing can vary, depending on the Palm
Organizer that you use.
While the data is being processed (display in "%" in the process
manager) in the Palm, you can remove the Palm from the locking,
because the Palm and the locking are no longer communicating.
Questo manuale è adatto per i seguenti modelli
4
Indice
Manuali Software popolari di altre marche

PS Audio
PS Audio PowerPlay Manuale del proprietario

Brady
Brady LOCKOUT PRO 3.0 Manuale di servizio

Avaya
Avaya Interaction Center Manuale utente

Texas Instruments
Texas Instruments TI-83 Plus Silver Edition Manuale

Novell
Novell GROUPWISE 8 - INTERNET AGENT Manuale utente

Oracle
Oracle Application 9i Manuale utente

Acer
Acer RDM Manuale utente

Canon
Canon Vixia HF21 Manuale utente

Canon
Canon ZR950 Manuale utente

Samsung
Samsung Auto Backup Manuale utente

Polycom
Polycom Vortex EF2201 Istruzioni per l'installazione e il funzionamento

Brocade Communications Systems
Brocade Communications Systems Brocade 8/12c Manuale utente