socomec DIRIS A40 Manuale utente

DIRISA-40
PMD - Multifunction meter
EN
INSTRUCTION
MANUAL
www.socomec.com/
catalogues-brochures_en.html

2EN DIRIS A-40 - 545802B - SOCOMEC
1. DOCUMENTATION .............................................................3
2. HAZARDS AND WARNINGS ....................................................4
2.1. Risk of electrocution, burns or explosion ................................4
2.2. Risk of damaging the device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.3. Responsibility........................................................5
3. PRELIMINARY OPERATIONS....................................................6
4. INTRODUCTION ...............................................................7
4.1. DIRISA-40 presentation ..............................................7
4.1.1. Range ....................................................7
4.1.2. Principle...................................................8
4.1.3. Functions..................................................9
4.1.4. Dimensions ...............................................11
4.1.5. Front panel ...............................................11
4.2. Presentation of associated current sensors.............................13
4.2.1. TE solid-core current sensors................................14
4.2.2. TR / iTR split-core current sensors ...........................16
4.2.3. TF flexible current sensors ..................................17
4.2.4. Adapters for 5A sensors ....................................18
5. INSTALLATION ...............................................................19
5.1. Recommendations and safety ........................................19
5.2. Installing DIRIS A-40.................................................19
5.3. Installing TE solid-core sensors .......................................20
5.3.1. Mounting accessories ......................................20
5.3.2. DIN rail mounting ..........................................20
5.3.3. Plate mounting ............................................22
5.3.4. Installing on a cable with clamping collar ......................24
5.3.5. Bar mounting .............................................25
5.3.6. Sensors assembly .........................................26
5.3.7. Sealing accessories for sensors..............................26
5.4. Installing TR split-core sensors .......................................27
5.4.1. Cable mounting ...........................................27
5.5. Installing TF Flexible current sensors ..................................28
5.5.1. Bar or cable mounting......................................28
5.6. Installing the 5A adapter .............................................29
6. CONNECTION ................................................................30
6.1. DIRIS A-40 connection...............................................30
6.2. Connection to the electrical network and to the loads ...................32
6.2.1. Configurable loads based on the network type .................32
6.2.2. Description of the main network and load combinations .........32
7. COMMUNICATION ............................................................34
7.1. Modbus General information .........................................34
7.2. RS485 rules ........................................................34
7.3. Modbus and Profibus communication tables ...........................34
8. CONFIGURATION .............................................................35
8.1. Configuration using Easy Config ......................................35
8.1.1. Connection modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
8.1.2. Using Easy Config .........................................37
8.2. Configuration from the display ........................................40
8.2.1. Navigation ................................................40
8.2.2. Description of the Wizard ...................................40
8.2.3. Complete configuration .....................................41
8.3. Screen menu structure...............................................43
EN CONTENTS:

3EN
DIRIS A-40 - 545802B - SOCOMEC
1. DOCUMENTATION
All documentation on the DIRISA-40 is available on the website
at the following address:
www.socomec.com/catalogues-brochures_en.html
9. USE .........................................................................44
9.1. Browse ............................................................44
9.2. Shortcuts ..........................................................44
9.3. Favourites ..........................................................44
9.4. Screen display of measurements......................................44
10. ALARMS ....................................................................45
10.1. Alarms upon events ................................................45
10.1.1. Electrical parameters ......................................45
10.1.2. Voltage and current unbalance (in a three-phase network) ......45
10.1.3. EN 50160 voltage quality events ............................46
10.1.4. Consumption ............................................46
10.1.5. Digital inputs .............................................46
10.1.6. Combination of alarms ....................................46
10.2. System alarms.....................................................47
10.2.1. Current/voltage compatibility ...............................47
10.2.2. Incorrect direction of rotation (three-phase network)............47
10.2.3. Faulty current sensor......................................47
10.3. Setting up alarms ..................................................47
10.3.1. ALARM LED on front......................................47
10.3.2. Activation of an output ....................................47
10.3.3. Activation of an input......................................48
10.3.4. RS485 Modbus ..........................................48
10.3.5. Screen and WEBVIEW ....................................48
11. WEB SERVER ...............................................................49
12. CHARACTERISTICS..........................................................50
12.1. DIRIS A-40 characteristics ..........................................50
12.1.1. Mechanical features.......................................50
12.1.2. Electrical specifications ....................................50
12.1.3. Measuring characteristics ..................................50
12.1.4. Input/output characteristics ................................51
12.1.5. Communication specifications ..............................51
12.1.6. Environmental specifications ...............................52
12.1.7. Electromagnetic compatibility...............................52
12.1.8. Safety ..................................................53
12.1.9. Service life...............................................53
12.2. TE, TR / iTR and TF sensor characteristics ............................54
13. PERFORMANCE CLASSES ...................................................56
13.1. Specification of the characteristics ...................................56
13.2. Evaluation of the power supply quality................................57

4EN DIRIS A-40 - 545802B - SOCOMEC
2. HAZARDS AND WARNINGS
The term "device" used in the paragraphs below refers to the DIRISA-40.
The assembly, use, servicing and maintenance of this product must only be carried out by trained, qualied
professionals.
SOCOMEC shall not be held responsible for failure to comply with the instructions in this manual.
2.1. Risk of electrocution, burns or explosion
Caution: risk of electric shock Ref. ISO 7000-0434B (2004-01)
Caution: refer to the accompanying documentation each time this
symbol is shown
Ref. ISO 7010-W001 (2011-05)
• Only duly authorised and qualied personnel may work or install/uninstall the device.
• The instructions are valid together with the specic instructions for the device.
• The device is designed only for its intended purpose as set out in the instructions.
• Only accessories authorised or recommended by SOCOMEC may be used in association with the device.
• Before proceeding with installation, maintenance, cleaning, disassembly, connection, or maintenance work,
the device and system must be cut off from the mains to avoid electrocution and damaging the system and
device.
• This device is not designed to be repaired by the user.
• For any questions related to the disposal of the device, please contact SOCOMEC.
Do NOT clamp or pull out NON-INSULATED conductors carrying DANGEROUS VOLTAGE which could
cause an electric shock, burn or arc ash.
Ref. IEC 61010-2-032
Failure to comply with the instructions of the device and this safety information can cause bodily injury,
electric shock, burns, death or damage to property.
2.2. Risk of damaging the device
Caution: risk of electric shock Ref. ISO 7000-0434B (2004-01)
Caution: refer to the accompanying documentation each time this
symbol is shown
Ref. ISO 7010-W001 (2011-05)
To ensure that the device operates correctly, make sure that:
• The device is correctly installed.
• There is a maximum voltage at the voltage measurement input terminals of 520 V AC phase-phase or 300 V
AC phase-neutral.
• There is a maximum voltage at the auxiliary power supply input terminals of 400 V AC.
• The network frequency indicated on the device is observed: 50 or 60 Hz.
• Always connect the TE, TR or TF current sensors using the recommended connection cables and observing
the maximum prescribed currents.
• When the ambient temperature exceeds +50°C, the minimum temperature rating of the copper cable to be
connected to terminal must be +85°C.
Failure to respect these precautions could cause damage to the device.

5EN
DIRIS A-40 - 545802B - SOCOMEC
2.3. Responsibility
• Assembly, connection and use must be carried out in accordance with the installation standards currently in
force.
• The device must be installed in accordance with the rules given in this manual.
• Failure to observe the rules for installing this unit may compromise the device's intrinsic protection.
• The device must be positioned within an installation which complies with the standards currently in force.
• Any cable which needs to be replaced may only be replaced with a cable having the correct rating.
• Despite constantly striving for quality in preparing this manual, errors or omissions are always a possibility and
are not the responsibility of SOCOMEC.

6EN DIRIS A-40 - 545802B - SOCOMEC
3. PRELIMINARY OPERATIONS
To ensure the safety of staff and the equipment, it is vital to read and absorb the contents of these instructions
thoroughly before commissioning.
Check the following points as soon as you receive the package containing the device:
• The packaging is in good condition
• The device has not been damaged during transit,
• The device part number conforms to your order
• The package includes:
- 1 device equipped with removable terminals
- 1 line resistor (ref. 48990019)
- 1 QuickStart guide

7EN
DIRIS A-40 - 545802B - SOCOMEC
4. INTRODUCTION
4.1. DIRISA-40 presentation
The DIRISA-40 is a compact PMD* with a 96*96 format. It is designed for measuring, monitoring and reporting
electrical energy. The DIRISA-40 offers a range of functions for measuring voltage, current, power, energy and
quality. It allows the analysis of a single-phase or three-phase load.
The DIRISA-40 has 3 digital inputs (pulse metering, status checking) and 2 outputs (Alarm or pulses). The standard
version of the device has RS485 Modbus communication. Depending on the models, Ethernet or Probus
communication may also be provided. The Ethernet model also has a built-in web server.
The connection mode for the current sensors allows quick, easy installation. Their automatic identication (type and
rating) by the DIRISA-40 signicantly reduces the risk of errors during installation. In addition, this approach, based
on combining the sensor with the DIRISA-40, means the overall accuracy of the DIRISA-40 + Current sensor
measurement chain can be guaranteed for all values measured.
The product is congured from the display or via the Easy Cong software. The measurements can be accessed via
the WEBVIEW web server, available on the DIRIS G-30, G-40, G-50 and G-60 communication gateways, enabling
real-time monitoring of the electrical values and reporting of the energy data. The data can also be accessed via the
N'VIEW energy management software.
*PMD: Performance Measuring and Monitoring Device in accordance with IEC 61557-12.
4.1.1. Range
DIRISA-40
Ref. 4825 0500 : Model with Modbus communication
Ref. 4825 0501 : Model with Modbus + Ethernet communication
Ref. 4825 0502 : Model with Modbus + Profibus communication

8EN DIRIS A-40 - 545802B - SOCOMEC
4.1.2. Principle
L1
L2
L3
N
Current sensors
TE, TR or TF

9EN
DIRIS A-40 - 545802B - SOCOMEC
4.1.3. Functions
The DIRISA-40 boasts numerous functions, including:
• General measurements
- Electrical values, voltage, current, frequency
- Power, power factor, cos phi and tan phi
- 4 quadrant operation
- Predictive power
- Overall accuracy of the DIRIS A-40 + Sensors measurement chain guarantees up to class 0.5
(depending on the current sensor used) in power and active energy in accordance with IEC 61557-12
• Quality
- Current, phase-to-neutral voltage and phase-to-phase voltage
- THD, TDD and harmonics up to level 63 for voltage and current
- Voltage and current crest factor
- Voltage and current unbalance
- K-factor
- EN50160 events (Uswl, Udip, Uint) and current overloads
• Data log
- Recording of averaged electrical values
- Recording and timestamping of min/max electrical values
• Metering
- Active, reactive, apparent energy total and partial
- Load curves
- Multi-tariff metering
• Alarm
- Timestamped alarms with boolean combination
- Advanced alarms
• Connection to the network
-
3 current inputs with automatic recognition of the current sensors by quick connection (type RJ12)
- Control of the connection, detection of the current sensors and auto-conguration of the networks
- Guaranteed overall accuracy of the DIRIS A-40 + Sensors measurement chain in accordance with IEC
61557-12
• Inputs/outputs
- 3 logic inputs
- 2 logic outputs
• Communication
- RS485 Modbus RTU
- RS485 Modbus RTU and Probus
- RS485 Modbus RTU and Ethernet (Modbus TCP, BACnet)
• Web Server
- Embedded Web Server for the DIRIS A-40 ethernet (Réf. 4825 0501)

10 EN DIRIS A-40 - 545802B - SOCOMEC
DIRISA-40
Reference
4825 0500 4825 0501 4825 0502
Number of current inputs 333
Metering
Total and partial Ea+, Ea-, Er+, Er-,
Eap •••
Multi-tariff (max. 8) •••
Multi-measurement
V1, V2, V3, Vn, U12, U23, U31, f
I1, I2, I3, IN • • •
P, Q, S, PF per phase, ∑P, ∑Q, ∑S,
∑PF •••
Predictive power P, Q, S • • •
Phi, cos Phi, tan Phi • • •
Quality
Voltage unbalance Vnba, Vnb, Unba,
Unb •••
Current unbalance
Inba, Inb •••
THDV1, THDV2, THDV3, THDVn,
THDU12, THDU23, THDU31 •••
THDI1, THDI2, THDI3, THDIn, THD
Isys, TDD •••
Individual harmonics V, U, I (up to level
63) •••
Crest Factor, k-factor • • •
Overvoltages, Voltage dips, Supply
voltage interruptions according to EN
50160
•••
Overcurrents • • •
Alarms
Thresholds • • •
Digital • • •
Boolean • • •
Inputs/Outputs
Number 3/2 3/2 3/2
Trends
Load curves •••
Energy index •
Average values •
Web Server
Power & Energy Monitoring •
Communication
RS485 RTU Modbus •
RS485 Modbus RTU and Probus
DPV1 •
RS485 Modbus RTU and Ethernet
(Modbus TCP, BACnet) •
SNTP, SMTP, FTP •
Altri manuali per DIRIS A40
14
Indice
Altri manuali socomec Multimetro
Manuali Multimetro popolari di altre marche

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuale utente

PeakTech
PeakTech 4000 Manuale per l'uso e la cura

YOKOGAWA
YOKOGAWA 90050B Manuale utente

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuale utente

Fluke
Fluke 8846A Manuale operativo e di manutenzione

Tempo Communications
Tempo Communications MM200 Manuale utente