3
Operang Instrucons
1.1 - Remove equipment and power cord from the box.
1.2 - Turn on the power cord.
1.3 - Conrm that the mer indicates the correct me and day. If they are not, adjust for the
current day and me.
1.4 - To switch on the device press the 0/I buon to posion I. A red light will light up, which
means the device is switched on.
1.5 - To switch o the equipment press the 0/I buon to posion 0. It will turn o the red
light, which means that the equipment is o.
2 - Manual Operaon
2.1 - Conrm that there are no people or animals in the room to be disinfected (some plants
are not ozone-resistant so to raise the concentraon to levels of disinfecon you should
remove them from the space). Close all doors or windows.
2.2 - Connect the device to the electrical power, press the 0/I buon to posion I (the 0/I
buon light will be on) and then press the Manual buon of the mer which will turn on a
red light on the mer. The equipment will start producing ozone immediately, so you should
leave the room and close the door (to calculate the me of operaon, see page 4).
2.3 - At the end of the me, enter the room, turn o the equipment (rst on the Timer
Manual buon, then put the 0/I buon at 0) and leave the space immediately , closing the
door.
2.4 - Return to the room aer 30 minutes, aer the ozone me of dissipaon in the room.
Note: DO NOT BREATHE OZONE DIRECTLY. Aer turning on the equipment LEAVE THE SPACE
IMMEDIATELY and only return to turn it o. According to OSHA standards, people should
not remain in a space where ozone is being produced for more than 1 minute per 30 m2.
3. Automac Operaon
3.1 - Conrm that there are no people or animals in the room to be disinfected (some plants
are not ozone-resistant so to raise the concentraon to levels of disinfecon you should
remove them from space). Close all doors or windows.
3.2 - Connect the device to the electrical power, press the 0/I buon to posion I (the 0/I
buon light will be on) and then set the mer for the desired disinfecon periods. The
equipment will start producing ozone according to the programmed mes. At the end of the
me, the equipment will stop producing the ozone.
3.3 - Ensure that the disinfecon schedule is for periods when no one is in the space and
ensures the end of the cycle with a minimum safety interval of 30 minutes before someone
returns to the space, to fully dissipate the ozone in the air.
3.4 - You can return to the room aer 30 minutes, so that you wait for the ozone dissipaon
me in the room, at the end of that period, switch the 0/I buon at the 0 posion and if you
wish, disconnect the equipment from the current.
..EN