9
Commissioning
- Automatic mode with height of tool alert function
For safety reasons, the rotation laser always switches itself off all when it is
switched on in this operating mode!
The unit can be switched on by briefly tapping button (3). Automatic levelling starts
immediately. The green LED (5b) lights up and the LED (4) flashes. The splitter pen-
taprism begins to rotate and the laser beam comes on. After automatic levelling,
you have approximately 30 seconds in which to set the laser unit in the desired
position, e.g. to adjust its height, set it on a tripod, etc.
During this time, minor discrepancies from the horizontal are ironed out. Then the
laser unit switches to monitored Automatic mode and the LED (4) goes out.
Operating modes:
Main applications:
Levelling
Set the unit on a firm base or a tripod.
Tip: It is useful to set up the rotation laser centrally to
the subsequent measurement points.
Pressing the button (3), switches the rotation laser ON
and it starts to level itself automatically. Once levelling
is complete, the laser begins to rotate. Depending on
the brightness of the ambient light, you can either use
the laser beam, if easily visible, for marking directly
(always ensure that you mark the centre of the laser
beam) or the beam can be received via the receiver.
Please note that the centre of laser dot is marked!
NB:
In Class II laser equipment, your eyes
are protected from accidental, short-
term exposure to the laser beam by
the lid-closing reflex and/or the reflex
reaction to turn one's head. This
equipment can therefore be used
without additional protective measu-
res. Nevertheless, you should not look
directly into the laser beam. The laser goggles enclosed with these
units are not safety goggles. They are desi-
gned to make the laser light easier to see.
Do not let the unit fall into children's
hands!
EN 60825-1 : 03 10
3
3
4