Stryker SYNK 4K Wireless System Manuale utente

Transmitter:
Receiver:
0240031065
0240031075
SYNK® 4K Wireless System
DRAFT

DRAFT

Contents
Warnings and Cautions ........................................................................... 1
Warnings.....................................................................................................................1
Cautions......................................................................................................................2
Product Description ................................................................................ 4
Intended Use.............................................................................................................4
System Features....................................................................................... 6
SYNK® 4K Wireless Transmitter Front Panel....................................................6
SYNK® 4K Wireless Transmitter Rear Panel......................................................7
SYNK® 4K Wireless Receiver Front Panel..........................................................8
SYNK® 4K Wireless Receiver Rear Panel............................................................9
Setup ......................................................................................................10
Device Compatibility........................................................................................... 10
Mounting the Receiver on a Display.............................................................. 11
Connecting Power from the AC Adapter ..................................................... 13
Connecting Power to the Receiver from a Display................................... 13
Setting up the SYNK®4K Wireless System .................................................... 13
Wireless Conguration.......................................................................... 16
Operation ...............................................................................................17
Pairing the Devices Using a Temporary Token (Blue) .............................. 17
Pairing the Devices Using a Permanent Token (Red)............................... 17
Removing a Permanent Link ............................................................................ 18
Troubleshooting ....................................................................................19
Cleaning .................................................................................................21
Cleaning and Disinfecting the Transmitter, Receiver, and Tokens ...... 21
Materials and Equipment .................................................................................. 22
Maintenance ..........................................................................................23
Inspecting the Transmitter and Receiver ..................................................... 23
Storage ..................................................................................................................... 23
Periodic Maintenance Schedule...................................................................... 23
Service Life.............................................................................................................. 23
Disposal.................................................................................................................... 24
Technical Specications........................................................................25
DRAFT

Electromagnetic Compatibility........................................................................ 28
Symbol Denitions................................................................................ 32
DRAFT

1
Warnings and Cautions
In this manual, the terms and denitions below apply.
• Warning: Possible injury to the patient or user.
• Caution: Possible damage to the equipment.
• Note: More information to clarify the instructions.
Warnings
To avoid potential serious injury to the user and the patient and/or damage to
this device, please note the following warnings.
1. Read this manual thoroughly and know its contents prior to using the
device.
2. Federal law (United States of America) restricts this device to sale by, or
on the order of, a physician.
3. This system is not suitable for use in the presence of ammable
anesthetic gases.
4. This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20 cm (7.9 inches) between the radiator
and your body.
5. Install this system in an operating room that complies with all applicable
IEC, CEC, and NEC requirements for safety of electrical devices. Any
installation or connection with other devices shall be evaluated for
electrical safety according to the IEC 60601-1.
6. This product is non-sterile and therefore should not be placed in the
sterile eld.
7. Although the device was fully tested at the factory before shipment,
the user should always test it for proper function prior to a surgical
procedure.
8. To achieve grounding reliability, connect the product to an AC adapter
that is connected to a hospital-grade power cord, and ensure the power
cord is plugged into a grounded power outlet. Do not use extension
power cords.
9. To avoid risk of electric shock, use only the hospital-grade power cord
furnished with the receiver and/or transmitter. Disconnect the receiver
and/or transmitter from the power supply to make connections or to
inspect the equipment.
10. Use Stryker HDMI cable only provided with the product. Use of third-
party HDMI cables with the camera console is not recommended due
DRAFT

2
to potential problems with secure connections or electromagnetic
compatibility. Use the provided HDMI high speed cable (or other Stryker-
approved HDMI cable) with the SYNK® 4K Wireless System.
11. Only connect items that have been specied as part of the SYNK® 4K
Wireless System or that have been specied as being compatible with the
system.
12. To avoid the risk of electric shock, this equipment must only be
connected to a supply mains with protective earth.
13. Do not place any heavy object on the power cord. Damage to the power
cord can cause re or electric shock.
14. Do not put any liquid or solid object into the device. If this occurs, unplug
the device and have it checked by qualied personnel before operating it
any further.
15. Use appropriate caution to prevent contact with uids if the receiver or
transmitter is being used with a power supply in patient environments.
16. To avoid electric shock, do not open the receiver or transmitter housings.
17. Do not modify this equipment without authorization of the manufacturer.
18. Attempt no internal repairs or adjustments not specically detailed in this
operating manual. Refer any adjustments, modications, and/or repairs to
Stryker Endoscopy or its authorized representatives.
19. Do not touch the device and a patient simultaneously, as there is a risk of
electric shock.
20. Do not touch the patient with signal input or output connectors.
Equipment with SIP/SOP connectors should either comply with
IEC60601-1 harmonized national standard or the combination should be
evaluated for safety.
21. For optimal operation of the SYNK® 4K Wireless System, leave a
minimum of 1m (3.3 ft) between any part of the System and portable RF
communications equipment.
22. To prevent tampering, physically secure the device when not in use.
Cautions
To avoid potential damage to this device, please note the following cautions.
1. Carefully unpack the system and check if any damage occurred during
shipment. If damage is detected, refer to the warranty.
2. Do not install the devices near sunlight, excessive dust, mechanical
vibration, or shock.
3. Keep the devices away from equipment that uses strong magnets (i.e.,
large loudspeakers).
DRAFT

3
4. To ensure electromagnetic compatibility, refer to the“Electromagnetic
Compatibility”section of this manual. The devices must be installed and
operated according to the EMC information provided in this manual.
5. Do not position the devices so that it is dicult to disconnect the power
cords from the supply mains.
6. Connect the devices to a hospital grade receptacle to achieve grounding
reliability.
7. To connect to an international power supply, use an attachment plug
appropriate for the power outlet.
8. Remove the power cord when transporting the devices.
9. Never operate the devices immediately after transportation from a cold
location to a warm location.
10. Power o the devices when they are not in use.
11. Unplug the receiver and transmitter if they are not to be used for an
extended period of time.
12. Pay close attention to the care and cleaning instructions in this manual. A
deviation may cause damage.
13. Changes or modications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
devices.
Note: This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving unit.
• Increase the separation distance between the units.
• Connect the unit to an outlet on a circuit dierent from that to which
the other unit(s) are connected.
• Consult the manufacturer or eld service technician for help.
The warranty is void if any of these warnings or cautions are disregarded.
These products contain electrical waste or electronic equipment. They must
not be disposed of as unsorted municipal waste and must be collected
separately.
DRAFT

4
Product Description
The SYNK® 4K Wireless System wirelessly transfers video data from a
transmitter to up to two linked receivers. The transmitter provides an HDMI
input that supports 1080p and 4K video formats, and the receiver provides an
HDMI output supporting the same formats. Once the devices are linked, the
transmitter wirelessly transfers high-denition video to the receiver for output
on a secondary display.
At least one transmitter, one receiver, and a pairing token are required for full
functionality of the system. A link between the transmitter and the receiver(s)
is established by manually inserting a token in the transmitter and then in
the receiver(s). Encrypted network data is written onto the token from the
transmitter, and the data is decrypted in the receiver to establish a private
and secure connection. A token is a small memory device that is programmed
with frequencies allowed to establish a link.
The receiver can optionally be mounted to the back of the 32” 4K Surgical
Display (0240031050), and it comes with the necessary mounting hardware.
A dedicated power supply is included with the transmitter and the receiver
to provide power. Alternatively, a Y-cable is provided with the receiver so it
can share the 32”4K Surgical Display’s power supply (use when the receiver is
mounted to the back of that display).
The system transfers video data without controlling or altering the functions
or parameters of any connected devices.
Intended Use
The SYNK® 4K Wireless System is intended for wireless transmission of high
denition video data to secondary displays in a professional healthcare
setting. The system is a non-sterile reusable device not intended for use in the
sterile eld.
Contraindications
There are no contraindications for these devices.
DRAFT

5
SYNK® 4K Wireless Transmitter
Package Contents
• (1) SYNK® 4K Wireless Transmitter (0240031065)
• (1) Hospital-grade power cord (0105033001)
• (1) HDMI high speed cable, 2M (P39077)
• (2) Remote cables (0105206758)
• (1) Power supply (P27315)
• (2) Temporary tokens (blue) (0105208884)
SYNK® 4K Wireless Receiver
Package Contents
• (1) Receiver (0240031075)
• (1) Hospital-grade power cord (0105033001)
• (1) Power supply (P27315)
• (2) Shoulder bolts (P44094)
• (1) Y cable (P43614)
• (1) HDMI high speed cable, 2M (P39077)
DRAFT

6
System Features
This section outlines the features of the SYNK® 4K Wireless Transmitter and
Receiver.
SYNK® 4K Wireless Transmitter Front Panel
124
5
3
1. Power switch
(hard)
Powers transmitter ON and OFF.
2. Power Indicator Steady Green - Power is ON
3. Token Status
Indicator
Blinking White - Waiting for normal token
Green - Ready for pairing or Wireless link is
established
Amber - Warning, see Troubleshooting
Red - Error, contact service representative
4. Token Slot Token insertion site used to establish a wireless
connection
5. Token Initializes a wireless connection after insertion into
the transmitter and receiver
Note: The transmitter emits a pairing sound when a wireless link is
established. The transmitter emits a link drop sound when one or both
receiver links have been dropped.