SuperLead 2200 Series Manuale utente

SuperLead
2200 Series
2D Imager Barcode
Scanner User Guide
V1.0

SuperLead
1
Table of Contents
Chapter 1 Factory Settings ................................................................................................................3
1. Factory Settings.............................................................................................................................3
Chapter 2 Communication Interface.................................................................................................4
1. RS-232 Serial Port Communication .........................................................................................4
1.1 Baud Rate Settings ............................................................................................................4
1.2 Parity Bit Settings..............................................................................................................4
2. USB Interface Communication..................................................................................................7
3. Serial Port Command Format ...................................................................................................7
Chapter 3 Common Function Settings ..............................................................................................9
1. Scanning Mode Settings ...........................................................................................................9
2. Beeper-Good Read Switching Settings .....................................................................................9
3. LED-Good Read Switching Settings.........................................................................................10
4. Barcode Scanning Delay..........................................................................................................10
5. Trigger Timeout Settings.........................................................................................................11
Chapter 4 Data Format Configuration ...........................................................................................12
1. General Settings......................................................................................................................12
2. Add Prefix................................................................................................................................13
3. Add Suffix................................................................................................................................13
4. Scanner Serial Number Display...............................................................................................13
5. Software Version Display ........................................................................................................14
Chapter5 Barcode Type...................................................................................................................15
1. 1D Barcode..............................................................................................................................15
1.1 Interleaved 2 of 5(Open by Default)..........................................................................15
1.2 China Post(Hong Kong)(Close by Default)..............................................................15
1.3 Matrix 2 of 5(Close by Default)..................................................................................15
1.4 Codabar(Open by Default)........................................................................................16
1.5 MSI(Plessey)(Close by Default)..................................................................................16

SuperLead
2
1.6 Code 128(Open by Default).......................................................................................16
1.7 Code 39(Open by Default).........................................................................................16
1.8 Code 93(Close by Default).........................................................................................17
1.9 Standard(IATA,Airline) 2 of 5(two-bar start/stop)(Close by Default).........................17
1.10 Industrial 2 of 5 (three-bar start/stop)(Close by Default)..........................................17
1.11 GS1 DataBar (RSS)(Close by Default).........................................................................17
1.12 Telepen(Close by Default)..........................................................................................18
1.13 Trioptic Code(Close by Default).................................................................................18
1.14 UPC-A/EAN13(Open by Default)................................................................................18
1.15 Code 11(Close by Default).........................................................................................19
2. 2D Barcode ..................................................................................................................................19
2.1 QR(Open by Default).................................................................................................19
2.2 Data Matrix(Open by Default)...................................................................................19
2.3 PDF417(Open by Default)..........................................................................................19
2.4 Aztec(Close by Default).............................................................................................21
2.5 Hanxin(Close by Default)...........................................................................................21

SuperLead
3
Chapter 1 Factory Settings
1. Factory Settings
Scanning the following barcode can restore the scanner to the factory defaults.
Restore All Factory Defaults

SuperLead
4
Chapter 2 Communication Interfaces
Superlead 2200 provides a TTL-232 interface and a USB interface to
communicate with the host device. The host device can receive scanned data
and send commands to control the engine or to access/alter the configuration
information of the engine via the TTL-232 or USB interface.
1. RS-232 Serial Communication
Serial communication interface is usually used when connecting the scanner to a host device (like PC,
POS). However, to ensure smooth communication and accuracy of data, you need to set communication
parameters (including baud rate, parity check, data bit and stop bit) to match the host device.
Default serial communication parameters are listed below. Make sure all parameters match the host
requirements.
Parameter
Default Setting
Serial Communication
Standard RS-232
Baud Rate
115200
Parity Check
None
Data Bits
8
Stop Bits
1
Hardware Flow Control
None
1.1 Baud Rate
1200 2400

SuperLead
5

SuperLead
6
4800 9600
19200 38400
57600 115200
1.2 Parity Check
None,7,1 None,7,2
None,8,1 Even,7,1
Even,7,2 Even,8,1

SuperLead
7
Odd,7,1 Odd,7,2
Odd,8,1
2. USB Interface Communication
To connect USB cable, scanners can communicate through USB HID-KB and USB
Virtual Serial Port.
USB HID-KB Configuration Code
USB Virtual Serial Port Configuration Code

SuperLead
8
3. Serial port command Format
User Command Format:
\x02\x11\x03XXXXXX.
Serial Command Trigger
Trigger push command: \x02P\x03
Trigger release command: \x02R\x03

SuperLead
9
Chapter 3 General Function Setting
1. Scanning Mode Settings
Manual Mode:Through Key Trigger to scan code
2. Beeper-Good Read Switching Setting
Open Good Read Beeper
Close Good Read Beeper
Indice
Altri manuali SuperLead Lettore di codici a barre
Manuali Lettore di codici a barre popolari di altre marche

POSMicro
POSMicro Datalogic PowerScan D7100 Manuale utente

Marson
Marson MT780 Guida rapida alla configurazione

NCR
NCR RealPOS Manuale utente

Motorola
Motorola SE3300 Guida rapida alla configurazione

Element
Element P130BT Manuale utente

Motorola
Motorola Symbol LS3008 Manuale di installazione e funzionamento