technetix AIMA-RFSW Manuale operativo

AIMA-RFSW
RF A/B
PROTECTION
SWITCH
Online
Email: customer.service.[email protected]
Website: technetix.com
2018-08/EN V1
Technetix Group Limited
Product user manual

2018-08/EN V1
Product user manual
AIMA-RFSW
Technetix Group Limited
Contents
1 About this manual .....................................................................................................................................................1
1.1 Related documentation ..............................................................................................................................................................................1
1.2 Technical support........................................................................................................................................................................................1
2 Precautions.................................................................................................................................................................2
3 Overview.....................................................................................................................................................................3
3.1 Product description ....................................................................................................................................................................................3
3.2 Product key features.................................................................................................................................................................................3
3.3 Specifications..............................................................................................................................................................................................4
3.3.1 Block diagram ...........................................................................................................................................................................................5
3.4 Order details................................................................................................................................................................................................5
4 Module characteristics .............................................................................................................................................6
4.1 Module appearance and port layout ....................................................................................................................................................6
4.1.1 Overview......................................................................................................................................................................................................6
4.1.2 Front panel layout....................................................................................................................................................................................7
4.1.3 Rear panel layout.....................................................................................................................................................................................8
5 Installation ..................................................................................................................................................................9
5.1 Preparatory work for installation ............................................................................................................................................................9
5.2 Unpacking....................................................................................................................................................................................................9
5.3 Module installation ....................................................................................................................................................................................10
5.4 Check module LEDs .................................................................................................................................................................................11
5.5 Test the RF input signal............................................................................................................................................................................11
6 Module configuration & alarm setup .....................................................................................................................12
6.1 Port configuration screen .........................................................................................................................................................................12
6.2 Restoring factory default .........................................................................................................................................................................14
6.3 Reboot...........................................................................................................................................................................................................15
6.4 Alarms monitoring......................................................................................................................................................................................17
6.4.1 Alarm status pages..................................................................................................................................................................................17

2018-08/EN V1
Product user manual
AIMA-RFSW
Technetix Group Limited
6.4.2 Module operating voltage and temperature alarm.....................................................................................................................18
6.4.3 Module port alarms................................................................................................................................................................................19
6.5 Alarm monitoring configuration.............................................................................................................................................................20
6.5.1 Monitoring function ON/OFF ...............................................................................................................................................................20
6.5.2 Temperature, +12V/+5V voltage alarm level management ......................................................................................................21
6.5.3 Input/Output status monitoring..........................................................................................................................................................22
6.6 Logs management ....................................................................................................................................................................................24
6.7 Device uprade.............................................................................................................................................................................................25
7 Troubleshooting.........................................................................................................................................................26
Appendix A: Default alarm limit settings......................................................................................................................27

12018-08/EN V1 Technetix Group Limited
Product user manual
AIMA-RFSW
1 About this manual
1.1 Related documentation
The following documents may be used in conjunction with this manual:
• AIMA3000 - Product User Manual
• AIMA ASMM - Product User Manual
• AIMA3000 NMS Web Management System Product User Manual
• NMS3-EPSM - Basic Inventory Management
• NMS3-EPSM - Basic Alarm Management
• NMS3-EPSM - Basic System Management
• NMS3-EPSM - Basic Template Management
1.2 Technical Support
If you need help in the process of setting up and maintaining RFSW, please contact Technetix customer service:
Europe:
Technetix BV
Kazemat 5
NL-3905 NR Veenendaal
P.O. Box 385
NL-3900 AJ Veenendaal
The Netherlands
Phone: +31 318 58 59 59
Email: customer.service.[email protected]

22018-08/EN V1 Technetix Group Limited
Product user manual
AIMA-RFSW
2 Precautions
WARNING!
This equipment is intended for indoor applications. To prevent fire or electrical shock, or
damage to the equipment, do not expose units to water or moisture.
■You should carefully read and thoroughly understand the contents of the manual before installing
and using this equipment.
■At any time, there may be dangerous voltage inside the device.
■DO NOT power up before the cover and the panels of the equipment are installed and the
enclosure is closed.
Cleaning
Only use a damp cloth to clean the front panel. Use a soft dry cloth to clean the top of the unit.
DO NOT use any spray cleaners or chemicals of any kind.
Outage or overload requiring service and repairs
Unplug the unit and refer the servicing to Technetix qualified service personnel only.
Servicing and repairs
DO NOT attempt to service this unit yourself. Refer all servicing needs to Technetix qualified service
personnel only.

32018-08/EN V1 Technetix Group Limited
Product user manual
AIMA-RFSW
3 Overview
3.1 About the Product
The RF A/B Protection Switch (RFSW) is designed to plug into the latest generation Advanced Intelligent Multi-services
Access platform - the AIMA3000.
Providing reliable radio signal stability, the RFSW is an RF-based switching device designed for automatic or manual
switching of radio signals. It maintains the RF output in the event of a loss or degraded signal of one of the two signals
connected to its inputs.
Engineered for high-isolation, the impedance-matched RF switch relay, is controlled by microcontroller-based logic circuits.
This intelligent microcontroller manages the switch based on the detection of RF input signal levels. In addition, the switch
can operate based on user-defined minimum and maximum RF threshold levels. The RFSW switching module provides
self-monitoring and communicates with the ASMM (AIMA3000 System Management Module) within the AIMA3000 chassis.
The switching action may be set to by automatic or manual operation. When in manual mode, the switch can be controlled
through the ASMM’s Web Interface, the AIMA hand-held controller, or through the NMSE. The module’s microcontroller
determines when to switch signals based on total RF power as commonly used in forward transmission, or based on pilot
tone detection of a single frequency as specified by the customer.
3.2 Product Key Features
■Plug-and-play AIMA3000 platform module
■Forward-path version (5 MHz to 1218 MHz) suits CENELEC and NTSC up to 158 channels (both analog and digital)
■Highly reliable, compact design
■Operates in AUTO or MANUAL mode
■Operator defined adjustable thresholds for both inputs with the maximum and minimum signal parameters
■Comprehensive remote monitoring
■Configurable alarm threshold levels
■Remote firmware upgrade and auto upload/download of configuration files through ASMM webinterface or
using the NMSE
■Bulk firmware updates through the NMSE
■FCC, CE and RCM(1) compliant
(1) See Declaration of Conformity for current status.

42018-08/EN V1 Technetix Group Limited
Product user manual
AIMA-RFSW
3.3 Specifications
RF performance
RF bandwidth 5 - 1218 MHz
RF flatness ± 0.5 dB
Insertion loss 3 dB maximum
Isolation < 65 dB (5 to 1000 MHz)
< 60 dB (1000 to 1218 MHz)
RF impedance 75 Ω
RF return loss > 16 dB
RF test point relative to RF output port -20 ± 1 dB
RF connectors 3 x GSK-type female
RF test points 3 x Mini-SMB
Switching time < 15 ms
Alarms and status Front-panel LEDS and SNMP traps
General
Power supply Powered via AIMA3000 backplane
Power consumption < 0.5 W
Operating temperature -5 - 55°C
Operating humidity Maximum 90 % (Non-condensing)
Storage temperature -25 - 70°C
Storage humidity 90% (non-condensing)
Dimensions (W*D*H) 24.6 * 410 * 152.5 mm
Weight 0.88 kg
Supported network management options The NMSE or through ASMM’s Web Interface

52018-08/EN V1 Technetix Group Limited
Product user manual
AIMA-RFSW
3.3.1 Block Diagram
Figure 3-1 RFSW block diagram
3.4 Order Details
A-RFSW-[Z] RF A/B protection switch
Options:
Z Bandwidth
1G 45 - 1000 MHz (Standard)
12 5 - 1218MHz

62018-08/EN V1 Technetix Group Limited
Product user manual
AIMA-RFSW
4 Module Characteristics
4.1 Module Appearance and Port Layout
4.1.1 Overview
Figure 4-1 Module appearance

72018-08/EN V1 Technetix Group Limited
Product user manual
AIMA-RFSW
4.1.2 Front panel view
Figure 4-2 FPAS Front panel layout
Table 4-1 FPAS Front Panel Functions
Item Number Item Description
1 MODE Module working mode indicator Manual: Green Light Blinking, 1 time per second Automatic: Green
2 STAT Module working status indicator Normal: Green Minor Alarm: Orange Major Alarm: Red
3 RF 1 IN LED Input A working mode indicator (Select input A, light blinking), 1 time per second Normal: Green
Minor Alarm: Orange Major Alarm: Red
4 RF 1 IN TP Input A testing point
5 RF 2 IN LED Input B working mode indicator (Select input B, light blinking), 1 time per second Normal: Green
Minor Alarm: Orange Major Alarm: Red
6 RF 2 IN TP Input B testing point
7 RF OUT LED RF working mode indicator Normal: Green Major Alarm: Red Minor Alarm: Orange
8 RF OUT TP RF output testing point
9 Tab-retaining clip Plug and fix the module. The tab-retaining clip will pop-up after pressing the
release and plug module.
10 Front screw Fix RFSW Module
Indice
Altri manuali technetix Interruttore