01
step
CONNECT AND CONFIGURE THP102-I PT100 ISOLATED TEMPERATURE HEAD TRANSMITTER
5
THP102-I PT100 ISOLATED TEMP. HEAD TRANSMITTER INSTALLATION GUIDE
09 To change the selected sensor settings,
update the value of the desire parameter and
select the “Write Device” option.
In this example, we use the default PT100
sensor type and change the “Temperature
Min.” to -100 and “Temperature Max.” to 0.
10 To conrm if the change has been
successfully completed, select the
“Read Device”.
11 Click on the “Read Temperature” button to
read the current temperature value.
12 If the temperature reading is outside the set
temperature range, the transmitter THP102-I
red and blue led will blink simultaneously.
Note: please review your settings and check the datasheet
status led information to analyse all the led behaviours.