4
1
2
3
4
5
Turn OFF/remove batteries from any Tx unit which is
not required to control this Rx unit. Turn off any other
Rx units.
If it is convenient more than one Rx unit can learn the
code of a Tx unit simultaneously in which case leave
these Rx units switched on.*
The TLRXC1 unit needs to be set in Program Mode. Plug
it in to a live socket (the first time this is done the unit
will go through its 6 choices of audible warning). Plug a
lamp into the unit’s socket and turn the lamp switch on.
The LED on the unit will flash slowly for 5 minutes
indicating it is in Program Mode.
Go to the Tx** unit to be introduced to the TLRXC1 and
move across the face of its PIR lens within detection
range to cause it to detect (indicated by the lights under
control turning on for most Tx units and by a flash
from the red LED on the TLTXDCB).
The TLRXC1 will respond with a “beep” and the lamp
plugged into it will turn on (indicating correct code
learning).
* Any other Rx units left connected should now be
checked in the same way.
If an additional Tx unit is required to be introduced
press the PROGRAM/RESET button for 1 to 2 seconds***
a single “beep” will sound and the LED will stop
flashing and stay on indicating exit from Program Mode.
Press this button again and the LED will start to flash
again indicating a new 5 minute period of Program Mode.
*Any other Rx units required to learn the code of this
new Tx unit should be left connected.
** If introducing the TLTXK2 hand held transmitter press
the “1” button on this unit to activate the TLRXC1.
***If the button is pressed for 5 seconds or more then all
the codes that have been learnt will be erased.
iTLRXC1_Instructions.qxd 1/19/05 11:55 AM Page 5